Image Scaling Difference Between a Confocal Scanning Laser Ophthalmoscope and a Flash Fundus Camera

被引:8
|
作者
Nittala, Muneeswar G. [1 ]
Hariri, Amirhossein [1 ]
Wong, Wai T. [3 ,4 ]
Chew, Emily Y. [3 ]
Ferris, Frederick L. [3 ]
Sadda, Srinivas R. [1 ,2 ]
机构
[1] Doheny Eye Inst, 1450 San Pablo St, Los Angeles, CA 90033 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA
[3] NEI, Div Epidemiol & Clin Applicat, NIH, Bethesda, MD 20892 USA
[4] NEI, Off Sci Director, NIH, Bethesda, MD 20892 USA
来源
关键词
GEOGRAPHIC ATROPHY; MACULAR DEGENERATION; AUTOFLUORESCENCE;
D O I
10.3928/23258160-20150909-13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate scaling and measurement differences between flash and scanning laser fundus images. PATIENTS AND METHODS: The authors analyzed fundus autofluorescence images of patients with geographic atrophy secondary to age-related macular degeneration imaged with both 30(sic) confocal scanning laser ophthalmoscope (cSLO) and 50(sic) flash fundus camera (FFC). Multiple vessel-crossing points served as landmarks. RESULTS: The mean (+/- SD; range) scaling factor between cSLO and FFC images (by GRADOR) for the horizontal dimension was 1.217 (+/- 0.0487; 1.0474-1.272) versus 1.138 (+/- 0.0311; 1.0841-1.193) for the vertical dimension. The mean percentage difference between horizontal and vertical scaling factors was 7.48 (+/- 2.29; 2.30-10.70). Refractive error (focus) and aperture size (or field of view of the image) were positively correlated and aspect ratio was negatively correlated with landmark pair measurements. CONCLUSION: Inherent image-scaling differences between fundus autofluorescence imaging systems are not restricted to simple pixel-to-millimeter calibration variances, but appear to vary depending on measurement orientation. Differences should be considered when comparing measurements obtained using different imaging systems, particularly for clinical trials.
引用
收藏
页码:872 / 879
页数:8
相关论文
共 50 条
  • [31] Imaging a child's fundus without dilation using a handheld confocal scanning laser ophthalmoscope
    Kelly, JP
    Weiss, AH
    Zhou, Q
    Schmode, S
    Dreher, AW
    ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (03) : 391 - 396
  • [32] CONFOCAL SCANNING LASER OPHTHALMOSCOPE WITH A SLIT APERTURE
    KOBAYASHI, K
    NAKANO, H
    MATSUI, H
    AKIYAMA, K
    ASAKURA, T
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (04) : 287 - 292
  • [33] Spectrally encoded confocal scanning laser ophthalmoscope
    Tao, Yuankai K.
    Izatt, Joseph A.
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [34] Optimization of confocal scanning laser ophthalmoscope design
    LaRocca, Francesco
    Dhalla, Al-Hafeez
    Kelly, Michael P.
    Farsiu, Sina
    Izatt, Joseph A.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (07)
  • [35] COMPUTERIZED STEREOIMAGE BY CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    FUNATSU, H
    MISHIMA, HK
    KIUCHI, Y
    KANEDA, K
    YAMASHITA, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1506 - 1506
  • [36] INDOCYANINE GREEN CHOROIDAL VIDEOANGIOGRAPHY - A COMPARISON OF IMAGING ANALYSIS WITH THE SCANNING LASER OPHTHALMOSCOPE AND THE FUNDUS CAMERA
    WOLF, S
    WALD, KJ
    ELSNER, AE
    STAURENGHI, G
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1993, 13 (03): : 266 - 269
  • [37] Normal values for fundus perimetry with the scanning laser ophthalmoscope
    Rohrschneider, K
    Becker, M
    Schumacher, N
    Fendrich, T
    Völcker, HE
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) : 52 - 58
  • [38] DIGITAL FUNDUS IMAGING USING A SCANNING LASER OPHTHALMOSCOPE
    MANIVANNAN, A
    SHARP, PF
    PHILLIPS, RP
    FORRESTER, JV
    PHYSIOLOGICAL MEASUREMENT, 1993, 14 (01) : 43 - 56
  • [39] Altered fundus appearance resulting from autofluorescence imaging with the confocal scanning laser ophthalmoscope (cSLO) in cats
    Occelli, Laurence M.
    Petersen-Jones, Simon M.
    VETERINARY OPHTHALMOLOGY, 2014, 17 (05) : 385 - 388
  • [40] IMAGE CONTROL IN THE SCANNING LASER OPHTHALMOSCOPE
    HUGHES, GW
    WEBB, RH
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1982, 29 (08) : 617 - 617