Image Scaling Difference Between a Confocal Scanning Laser Ophthalmoscope and a Flash Fundus Camera

被引:8
|
作者
Nittala, Muneeswar G. [1 ]
Hariri, Amirhossein [1 ]
Wong, Wai T. [3 ,4 ]
Chew, Emily Y. [3 ]
Ferris, Frederick L. [3 ]
Sadda, Srinivas R. [1 ,2 ]
机构
[1] Doheny Eye Inst, 1450 San Pablo St, Los Angeles, CA 90033 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA
[3] NEI, Div Epidemiol & Clin Applicat, NIH, Bethesda, MD 20892 USA
[4] NEI, Off Sci Director, NIH, Bethesda, MD 20892 USA
来源
关键词
GEOGRAPHIC ATROPHY; MACULAR DEGENERATION; AUTOFLUORESCENCE;
D O I
10.3928/23258160-20150909-13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate scaling and measurement differences between flash and scanning laser fundus images. PATIENTS AND METHODS: The authors analyzed fundus autofluorescence images of patients with geographic atrophy secondary to age-related macular degeneration imaged with both 30(sic) confocal scanning laser ophthalmoscope (cSLO) and 50(sic) flash fundus camera (FFC). Multiple vessel-crossing points served as landmarks. RESULTS: The mean (+/- SD; range) scaling factor between cSLO and FFC images (by GRADOR) for the horizontal dimension was 1.217 (+/- 0.0487; 1.0474-1.272) versus 1.138 (+/- 0.0311; 1.0841-1.193) for the vertical dimension. The mean percentage difference between horizontal and vertical scaling factors was 7.48 (+/- 2.29; 2.30-10.70). Refractive error (focus) and aperture size (or field of view of the image) were positively correlated and aspect ratio was negatively correlated with landmark pair measurements. CONCLUSION: Inherent image-scaling differences between fundus autofluorescence imaging systems are not restricted to simple pixel-to-millimeter calibration variances, but appear to vary depending on measurement orientation. Differences should be considered when comparing measurements obtained using different imaging systems, particularly for clinical trials.
引用
收藏
页码:872 / 879
页数:8
相关论文
共 50 条
  • [21] Multifocal ERG recording with simultaneous fundus monitoring using a confocal scanning laser ophthalmoscope
    C M Poloschek
    V Rupp
    H Krastel
    F G Holz
    Eye, 2003, 17 : 159 - 166
  • [22] Comparison of fundus autofluorescence images acquired by the confocal scanning laser ophthalmoscope (488 nm excitation) and the modified Topcon fundus camera (580 nm excitation)
    Deli, A.
    Moetteli, L.
    Ambresin, A.
    Mantel, I.
    INTERNATIONAL OPHTHALMOLOGY, 2013, 33 (06) : 635 - 643
  • [23] Multifocal ERG recording with simultaneous fundus monitoring using a confocal scanning laser ophthalmoscope
    Poloschek, CM
    Rupp, V
    Krastel, H
    Holz, FG
    EYE, 2003, 17 (02) : 159 - 166
  • [24] Comparison of fundus autofluorescence images acquired by the confocal scanning laser ophthalmoscope (488 nm excitation) and the modified Topcon fundus camera (580 nm excitation)
    A. Deli
    L. Moetteli
    A. Ambresin
    I. Mantel
    International Ophthalmology, 2013, 33 : 635 - 643
  • [25] Confocal scanning laser ophthalmoscopy versus modified conventional fundus camera for fundus autofluorescence
    Calvo-Maroto, Ana M.
    Esteve-Taboada, Jose J.
    Dominguez-Vicent, Alberto
    Perez-Cambrodi, Rafael J.
    Cervino, Alejandro
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (10) : 965 - 978
  • [26] Inverse image alignment method for image mosaicing and video stabilization in fundus indocyanine green angiography under confocal scanning laser ophthalmoscope
    Zhou, YJ
    Xue, H
    Wan, MX
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2003, 27 (06) : 513 - 523
  • [27] DISTRIBUTION OF FUNDUS AUTOFLUORESCENCE WITH A SCANNING LASER OPHTHALMOSCOPE
    VONRUCKMANN, A
    FITZKE, FW
    BIRD, AC
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (05) : 407 - 412
  • [28] Disparity between fundus camera and scanning laser ophthalmoscope indocyanine green imaging of retinal pigment epithelium detachments
    Flower, RW
    Csaky, KG
    Murphy, RP
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 1998, 18 (03): : 260 - 268
  • [29] KINETIC FUNDUS PERIMETRY WITH THE SCANNING LASER OPHTHALMOSCOPE
    ROHRSCHNEIDER, K
    BECKER, M
    FENDRICH, T
    VOLCKER, HE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1995, 207 (02) : 102 - 110
  • [30] CONFOCAL LASER SCANNING OPHTHALMOSCOPE - REPRODUCIBILITY OF OPTIC-NERVE HEAD TOPOGRAPHIC MEASUREMENTS WITH THE CONFOCAL LASER SCANNING OPHTHALMOSCOPE
    CIOFFI, GA
    ROBIN, AL
    EASTMAN, RD
    PERELL, HF
    SAFARAZI, FA
    KELMAN, SE
    OPHTHALMOLOGY, 1993, 100 (01) : 57 - 62