Interferometric measurement of the axial length of the eye

被引:0
|
作者
Hård, S [1 ]
Fuxin, PO [1 ]
Gerhardsson, D [1 ]
Torstensson, PA [1 ]
Nilsson, T [1 ]
Sjöstrand, J [1 ]
机构
[1] Chalmers Univ Technol, S-41296 Gothenburg, Sweden
关键词
interferometry; eye length measurement; axial length; bifocal lens;
D O I
10.1117/12.339166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A fast and accurate fiberoptic-based interferometer for non-contact measurements of the axial length of the eye was constructed and tested. A novelty of the interferometer design is the use of a diffractive, bifocal lens, which simultaneously focuses on the cornea and on the retina. A superluminescent light emitting diode with a coherence length of 30 mu m is used as light source. The axial length of the eye is measured by rapidly translating a reference mirror a distance covering the axial length. The estimated accuracy of a measurement is about 100 mu m, a number which compares well with those of conventional ultrasonic-based measurements.
引用
收藏
页码:179 / 181
页数:3
相关论文
共 50 条
  • [31] ULTRASOUND MEASUREMENT OF OCULAR AXIAL LENGTH
    FLEDELIUS, H
    ACTA OPHTHALMOLOGICA, 1972, 50 (04) : 617 - +
  • [32] NEUTRON INTERFEROMETRIC MEASUREMENT OF THE COHERENT SCATTERING LENGTH OF HOLMIUM
    BOUCHERLE, JX
    KISCHKO, U
    SCHWEIZER, J
    ACTA CRYSTALLOGRAPHICA SECTION A, 1985, 41 (NOV): : 589 - 590
  • [33] FRACTIONAL ORDER SLIDE RULE FOR INTERFEROMETRIC LENGTH MEASUREMENT
    HART, KH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1960, 31 (04): : 438 - 439
  • [34] NEUTRON INTERFEROMETRIC MEASUREMENT OF THE COHERENT SCATTERING LENGTH OF COBALT
    KISCHKO, U
    SCHWEIZER, J
    TASSET, F
    ZEITSCHRIFT FUR PHYSIK A-HADRONS AND NUCLEI, 1982, 307 (02): : 163 - 165
  • [35] High sensitive measurement of the human axial eye length in vivo with Fourier domain low coherence interferometry
    Grajciar, Branislav
    Pircher, Michael
    Hitzenberger, Christoph K.
    Findl, Oliver
    Fercher, Adolf F.
    OPTICS EXPRESS, 2008, 16 (04) : 2405 - 2414
  • [36] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [37] Influence of Dry Eye Disease on the Measurement Repeatability of Corneal Curvature Radius and Axial Length in Patients with Cataract
    Hiraoka, Takahiro
    Asano, Hiroki
    Ogami, Tomohiro
    Nakano, Shinichiro
    Okamoto, Yoshifumi
    Yamada, Yoshiaki
    Oshika, Tetsuro
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [38] AXIAL LENGTH MEASUREMENTS AND FUNDUS CHANGES OF MYOPIC EYE
    CURTIN, BJ
    KARLIN, DB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1971, 71 (01) : 42 - &
  • [39] The role of eye axial length in planning strabismus surgery
    Galantuomo, Maria Silvana
    Fossarello, Maurizio
    Cuccu, Alberto
    Zucca, Ignazio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [40] PERIPHERAL CHORIORETINAL LESIONS AND AXIAL LENGTH OF MYOPIC EYE
    KARLIN, DB
    CURTIN, BJ
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1976, 81 (05) : 625 - 635