Interferometric measurement of the axial length of the eye

被引:0
|
作者
Hård, S [1 ]
Fuxin, PO [1 ]
Gerhardsson, D [1 ]
Torstensson, PA [1 ]
Nilsson, T [1 ]
Sjöstrand, J [1 ]
机构
[1] Chalmers Univ Technol, S-41296 Gothenburg, Sweden
关键词
interferometry; eye length measurement; axial length; bifocal lens;
D O I
10.1117/12.339166
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A fast and accurate fiberoptic-based interferometer for non-contact measurements of the axial length of the eye was constructed and tested. A novelty of the interferometer design is the use of a diffractive, bifocal lens, which simultaneously focuses on the cornea and on the retina. A superluminescent light emitting diode with a coherence length of 30 mu m is used as light source. The axial length of the eye is measured by rapidly translating a reference mirror a distance covering the axial length. The estimated accuracy of a measurement is about 100 mu m, a number which compares well with those of conventional ultrasonic-based measurements.
引用
收藏
页码:179 / 181
页数:3
相关论文
共 50 条
  • [1] Interferometric measurement of the axial length of the eye
    Hard, Sverker
    Fuxin, Per-Ola
    Gerhardsson, Dan
    Torstensson, Per-Arne
    Nilsson, Tomas
    Sjostrand, Johan
    Proceedings of SPIE - The International Society for Optical Engineering, 3564 : 179 - 181
  • [2] Transpalpebral measurement of axial eye length
    Martius, P.
    Tech, S.
    Stachs, O.
    Guthoff, R. F.
    OPHTHALMOLOGE, 2010, 107 (08): : 733 - 739
  • [3] ULTRASOUND VELOCITIES FOR AXIAL EYE LENGTH MEASUREMENT
    HOFFER, KJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (05): : 554 - 562
  • [4] THE ACCURACY OF ULTRASONIC MEASUREMENT OF THE AXIAL LENGTH OF THE EYE
    BINKHORST, RD
    OPHTHALMIC SURGERY AND LASERS, 1981, 12 (05): : 363 - 365
  • [5] Measurement of the axial eye length by wavelength tuning interferometry
    Lexer, F
    Hitzenberger, CK
    Kulhavy, M
    Fercher, AF
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 202 - 206
  • [6] Large coherence length swept source for axial length measurement of the eye
    Chong, Changho
    Suzuki, Takuya
    Totsuka, Kohki
    Morosawa, Atsushi
    Sakai, Tooru
    APPLIED OPTICS, 2009, 48 (10) : D144 - D150
  • [7] A low coherence ''white light'' interferometric sensor for eye length measurement
    Wang, DN
    Chen, S
    Grattan, KTV
    Palmer, AW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12): : 5464 - 5468
  • [8] AXIAL LENGTH OF EYE
    ITIN, W
    BRAWANT, L
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1968, 65 (06) : 933 - &
  • [9] ULTRASONOGRAPHIC MEASUREMENT OF THE POSTERIOR COATS OF THE EYE AND THEIR RELATION TO AXIAL LENGTH
    GUTHOFF, R
    BERGER, RW
    DRAEGER, J
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1987, 225 (05) : 374 - 376