SILICON MICRODOSIMETRY

被引:21
|
作者
Agosteo, Stefano [1 ,2 ]
Pola, Andrea [1 ,2 ]
机构
[1] Politecn Milan, Dipartimento Energia, Sez Ingn Nucl CeSNEF, I-20133 Milan, Italy
[2] Ist Nazl Fis Nucl, Sez Milano, I-20133 Milan, Italy
关键词
SOLID-STATE MICRODOSIMETER; PROPORTIONAL-COUNTERS; TELESCOPE; DETECTORS; PERFORMANCE; PHOTODIODE; THERAPY;
D O I
10.1093/rpd/ncq408
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Silicon detectors are being studied as microdosemeters since they can provide sensitive volumes of micrometric dimensions. They can be applied for assessing single-event effects in electronic instrumentation exposed to complex fields around high-energy accelerators or in space missions. When coupled to tissue-equivalent converters, they can be used for measuring the quality of radiation therapy beams or for dosimetry. The use of micrometric volumes avoids the contribution of wall effects to the measured spectra. Further advantages of such detectors are their compactness, cheapness, transportability and a low sensitivity to vibrations. The following problems need to be solved when silicon devices are used for microdosimetry: (i) the sensitive volume has to be confined in a region of well-known dimensions; (ii) the electric noise limits the minimum detectable energy; (iii) corrections for tissue-equivalency should be made; (iv) corrections for shape equivalency should be made when referring to a spherical simulated site of tissue; (v) the angular response should be evaluated carefully; (vi) the efficiency of a single detector of micrometric dimensions is very poor and detector arrays should be considered. Several devices have been proposed as silicon microdosemeters, based on different technologies (telescope detectors, silicon on insulator detectors and arrays of cylindrical p-n junctions with internal amplification), in order to satisfy the issues mentioned above.
引用
收藏
页码:409 / 415
页数:7
相关论文
共 50 条
  • [11] Silicon 3D Microdetectors for Microdosimetry in Hadron Therapy
    Guardiola, Consuelo
    Fleta, Celeste
    Quirion, David
    Pellegrini, Giulio
    Gomez, Faustino
    MICROMACHINES, 2020, 11 (12) : 1 - 20
  • [12] Simulations of silicon microdosimetry measurements in fast neutron therapy.
    Cornelius I.
    Rosenfeld A.
    Bradley P.
    Australasian Physical and Engineering Sciences in Medicine, 2002, 25 (04): : 168 - 171
  • [13] Validation of Geant4 for silicon microdosimetry in heavy ion therapy
    Bolst, D.
    Guatelli, S.
    Tran, L. T.
    Chartier, L.
    Davis, J.
    Biasi, G.
    Prokopovich, D. A.
    Pogossov, A.
    Reinhard, M., I
    Petasecca, M.
    Lerch, M. L. F.
    Matsufuji, N.
    Povoli, M.
    Summanwar, A.
    Kok, A.
    Jackson, M.
    Rosenfeld, A. B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (04):
  • [14] MICRODOSIMETRY
    ROSSI, HH
    RADIATION RESEARCH, 1970, 43 (01) : 205 - &
  • [15] Evaluation of silicon based microdosimetry for Boron Neutron Capture Therapy Quality Assurance
    Vohradsky, James
    Guatelli, Susanna
    Davis, Jeremy A.
    Linh T Tran
    Rosenfeld, Anatoly B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 66 : 8 - 14
  • [16] Verification of Monte Carlo calculations in fast neutron therapy using silicon microdosimetry
    Cornelius, IM
    Rosenfeld, AB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 873 - 877
  • [17] Tissue Equivalence Correction in Silicon Microdosimetry for Protons Characteristic of the LEO Space Environment
    Guatelli, S.
    Reinhard, M. I.
    Mascialino, B.
    Prokopovich, D. A.
    Dzurak, A. S.
    Zaider, M.
    Rosenfeld, A. B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3407 - 3413
  • [18] Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy
    Bradley, PD
    Rosenfeld, AB
    MEDICAL PHYSICS, 1998, 25 (11) : 2220 - 2225
  • [19] Characterization of the Charge Collection Efficiency in Silicon 3-D-Detectors for Microdosimetry
    Bachiller-Perea, Diana
    Garcia Lopez, Javier
    del Carmen Jimenez-Ramos, Maria
    Gomez, Faustino
    Fleta, Celeste
    Quirion, David
    Garcia-Osuna, Adrian
    Guardiola, Consuelo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [20] The Next Step in Cylindrical Silicon-on-Insulator Microdosimetry: Charge Collection Results
    Ziebell, A. L.
    Lai, N. S.
    Lim, W. H.
    Reinhard, M. I.
    Prokopovich, D. A.
    Siegele, R.
    Dzurak, A. S.
    Rosenfeld, A. B.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 363 - +