Tissue equivalence correction for silicon microdosimetry detectors in boron neutron capture therapy

被引:41
|
作者
Bradley, PD [1 ]
Rosenfeld, AB [1 ]
机构
[1] Univ Wollongong, Radiat Phys Grp, Wollongong, NSW 2522, Australia
关键词
BNCT; microdosimetry; tissue equivalence;
D O I
10.1118/1.598421
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reverse-biased silicon p-n junction arrays have been proposed as microdosimetry detectors. The tissue equivalence of such detectors in boron neutron capture therapy (BNCT) is discussed. A comparison of the range-energy relationships of H, He, C, and Li ions in tissue (ICRU-muscle) and silicon is given. A simple geometrical scaling (similar to 0.63) of linear dimensions is required to convert microdosimetric energy deposition measurements performed in silicon to equivalent deposition in tissue. The Monte Carlo technique is used to examine energy deposition for two simple geometrical cases applicable to BNCT. (C) 1998 American Association of Physicists in Medicine. [S0094-2405(98)00710-X].
引用
收藏
页码:2220 / 2225
页数:6
相关论文
共 50 条
  • [1] Performance of silicon microdosimetry detectors in boron neutron capture therapy
    Bradley, PD
    Rosenfeld, AB
    Allen, B
    Coderre, J
    Capala, J
    RADIATION RESEARCH, 1999, 151 (03) : 235 - 243
  • [2] MICRODOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY
    WUU, CS
    AMOLS, HI
    KLIAUGA, P
    REINSTEIN, LE
    SARAF, S
    RADIATION RESEARCH, 1992, 130 (03) : 355 - 359
  • [3] Microdosimetry for boron neutron capture therapy: A review
    Robert G. Zamenhof
    Journal of Neuro-Oncology, 1997, 33 : 81 - 91
  • [4] Microdosimetry for boron neutron capture therapy: A review
    Zamenhof, RG
    JOURNAL OF NEURO-ONCOLOGY, 1997, 33 (1-2) : 81 - 92
  • [5] Evaluation of silicon based microdosimetry for Boron Neutron Capture Therapy Quality Assurance
    Vohradsky, James
    Guatelli, Susanna
    Davis, Jeremy A.
    Linh T Tran
    Rosenfeld, Anatoly B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 66 : 8 - 14
  • [6] Boron Neutron Capture Therapy: Microdosimetry at Different Boron Concentrations
    Conte, Valeria
    Bianchi, Anna
    Selva, Anna
    APPLIED SCIENCES-BASEL, 2024, 14 (01):
  • [7] Application of TEPC microdosimetry to boron neutron capture therapy
    Burmeister, J
    Kota, C
    Maughan, RL
    Waker, AJ
    Riley, K
    Wielopolski, L
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 351 - 352
  • [8] Macro- and microdosimetry for boron neutron capture therapy with a MOSFET
    Rosenfeld, AB
    Kaplan, GI
    Carolan, MG
    Allen, BJ
    Kota, C
    Yudelev, M
    Maughan, R
    Coderre, JA
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A198 - A204
  • [9] An innovative approach for microdosimetry analysis in boron neutron capture therapy
    Lu, XQ
    Kiger, WS
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 605 - 608
  • [10] Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy
    Selva, A.
    Bellan, L.
    Bianchi, A.
    Giustiniani, G.
    Colautti, P.
    Fagotti, E.
    Pisent, A.
    Conte, V.
    APPLIED RADIATION AND ISOTOPES, 2022, 182