Microdosimetry for boron neutron capture therapy: A review

被引:25
|
作者
Zamenhof, RG [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA 02215
关键词
boron; neutron; capture; microdosimetry; alpha; cancer;
D O I
10.1023/A:1005725415807
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A review of the microdosimetry of boron neutron capture therapy is present focusing on the progression of key scientific ideas and developments in this field rather than on a comprehensive and inclusive review of the literature. The author concludes that from a microdosimetry perspective the field is highly advanced, but what is lacking is the correlation of the proposed models and results with experimental radiobiological data.
引用
收藏
页码:81 / 92
页数:12
相关论文
共 50 条
  • [1] Microdosimetry for boron neutron capture therapy: A review
    Robert G. Zamenhof
    Journal of Neuro-Oncology, 1997, 33 : 81 - 91
  • [2] MICRODOSIMETRY FOR BORON NEUTRON-CAPTURE THERAPY
    WUU, CS
    AMOLS, HI
    KLIAUGA, P
    REINSTEIN, LE
    SARAF, S
    RADIATION RESEARCH, 1992, 130 (03) : 355 - 359
  • [3] Boron Neutron Capture Therapy: Microdosimetry at Different Boron Concentrations
    Conte, Valeria
    Bianchi, Anna
    Selva, Anna
    APPLIED SCIENCES-BASEL, 2024, 14 (01):
  • [4] Application of TEPC microdosimetry to boron neutron capture therapy
    Burmeister, J
    Kota, C
    Maughan, RL
    Waker, AJ
    Riley, K
    Wielopolski, L
    RADIATION PROTECTION DOSIMETRY, 2002, 99 (1-4) : 351 - 352
  • [5] Macro- and microdosimetry for boron neutron capture therapy with a MOSFET
    Rosenfeld, AB
    Kaplan, GI
    Carolan, MG
    Allen, BJ
    Kota, C
    Yudelev, M
    Maughan, R
    Coderre, JA
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : A198 - A204
  • [6] Performance of silicon microdosimetry detectors in boron neutron capture therapy
    Bradley, PD
    Rosenfeld, AB
    Allen, B
    Coderre, J
    Capala, J
    RADIATION RESEARCH, 1999, 151 (03) : 235 - 243
  • [7] An innovative approach for microdosimetry analysis in boron neutron capture therapy
    Lu, XQ
    Kiger, WS
    RESEARCH AND DEVELOPMENT IN NEUTRON CAPTURE THERAPY, 2002, : 605 - 608
  • [8] Microdosimetry of an accelerator based thermal neutron field for Boron Neutron Capture Therapy
    Selva, A.
    Bellan, L.
    Bianchi, A.
    Giustiniani, G.
    Colautti, P.
    Fagotti, E.
    Pisent, A.
    Conte, V.
    APPLIED RADIATION AND ISOTOPES, 2022, 182
  • [9] Microdosimetry of neutron field for boron neutron capture therapy at Kyoto University Reactor
    Endo, S
    Onizuka, Y
    Ishikawa, M
    Takada, M
    Sakurai, Y
    Kobayashi, T
    Tanaka, K
    Hoshi, M
    Shizuma, K
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 641 - 644
  • [10] The microdosimetry of boron neutron capture therapy in a randomised ellipsoidal cell geometry
    Nichols, TL
    Miller, LF
    Kabalka, GW
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 466 - 469