Calibration of CO, NO2, and O3 Using Airify: A Low-Cost Sensor Cluster for Air Quality Monitoring

被引:23
|
作者
Ionascu, Marian-Emanuel [1 ]
Castell, Nuria [2 ]
Boncalo, Oana [1 ]
Schneider, Philipp [2 ]
Darie, Marius [3 ]
Marcu, Marius [1 ]
机构
[1] Politehn Univ Timisoara, Fac Automat & Comp, Timisoara 300223, Romania
[2] Norwegian Inst Air Res NILU, N-2007 Kjeller, Norway
[3] Natl Inst Res & Dev Mine Safety & Protect Explos, Petrosani 332047, Romania
关键词
air pollution sensors; air quality monitoring; data quality; electrochemical sensors; low-cost sensors; sensor calibration; PERFORMANCE EVALUATION; FIELD CALIBRATION; AVAILABLE SENSORS; PART; MICROSENSORS; MODEL;
D O I
10.3390/s21237977
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During the last decade, extensive research has been carried out on the subject of low-cost sensor platforms for air quality monitoring. A key aspect when deploying such systems is the quality of the measured data. Calibration is especially important to improve the data quality of low-cost air monitoring devices. The measured data quality must comply with regulations issued by national or international authorities in order to be used for regulatory purposes. This work discusses the challenges and methods suitable for calibrating a low-cost sensor platform developed by our group, Airify, that has a unit cost five times less expensive than the state-of-the-art solutions (approximately euro1000). The evaluated platform can integrate a wide variety of sensors capable of measuring up to 12 parameters, including the regulatory pollutants defined in the European Directive. In this work, we developed new calibration models (multivariate linear regression and random forest) and evaluated their effectiveness in meeting the data quality objective (DQO) for the following parameters: carbon monoxide (CO), ozone (O-3), and nitrogen dioxide (NO2). The experimental results show that the proposed calibration managed an improvement of 12% for the CO and O-3 gases and a similar accuracy for the NO2 gas compared to similar state-of-the-art studies. The evaluated parameters had different calibration accuracies due to the non-identical levels of gas concentration at which the sensors were exposed during the model's training phase. After the calibration algorithms were applied to the evaluated platform, its performance met the DQO criteria despite the overall low price level of the platform.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Calibration Model of a Low-Cost Air Quality Sensor Using an Adaptive Neuro-Fuzzy Inference System
    Alhasa, Kemal Maulana
    Nadzir, Mohd Shahrul Mohd
    Olalekan, Popoola
    Latif, Mohd Talib
    Yusup, Yusri
    Faruque, Mohammad Rashed Iqbal
    Ahamad, Fatimah
    Abd Hamid, Haris Hafizal
    Aiyub, Kadaruddin
    Ali, Sawal Hamid Md
    Khan, Md Firoz
    Abu Samah, Azizan
    Yusuff, Imran
    Othman, Murnira
    Hassim, Tengku Mohd Farid Tengku
    Ezani, Nor Eliani
    SENSORS, 2018, 18 (12)
  • [32] ARIMA forecasting of ambient air pollutants (O3, NO, NO2 and CO)
    Ujjwal Kumar
    V. K. Jain
    Stochastic Environmental Research and Risk Assessment, 2010, 24 : 751 - 760
  • [33] Outdoor-indoor air quality in Riyadh:: NO, NO2, and O3
    Al-Rehaili, A
    AIR POLLUTION VII, 1999, 6 : 507 - 517
  • [34] ARIMA forecasting of ambient air pollutants (O3, NO, NO2 and CO)
    Kumar, Ujjwal
    Jain, V. K.
    STOCHASTIC ENVIRONMENTAL RESEARCH AND RISK ASSESSMENT, 2010, 24 (05) : 751 - 760
  • [35] Optimization of the design of air quality monitoring networks and its application to NO2 and O3 in Jaen, Spain
    Lozano, Antonio
    Usero, Jose
    Vanderlinden, Eva
    Raez, Juan
    Contreras, Juan
    Navarrete, Benito
    El Bakouri, Hicham
    MICROCHEMICAL JOURNAL, 2010, 96 (02) : 406 - 411
  • [36] Advancing air quality monitoring: A low-cost sensor network in motion - Part I
    Correia, Carolina
    Santana, Pedro
    Martins, Vania
    Mariano, Pedro
    Almeida, Alexandre
    Almeida, Susana Marta
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2024, 360
  • [37] A Dual-Path Deep Learning Model for Low-Cost Air Quality Sensor Calibration
    Liu, Pang-Chun
    Chou, Ting-I.
    Chiu, Shih-Wen
    Tang, Kea-Tiong
    IEEE SENSORS JOURNAL, 2024, 24 (23) : 39914 - 39922
  • [38] RCH: Robust Calibration Based on Historical Data for Low-Cost Air Quality Sensor Deployments
    Li, Guodong
    Ma, Rui
    Liu, Xinyu
    Wang, Yue
    Zhang, Lin
    UBICOMP/ISWC '20 ADJUNCT: PROCEEDINGS OF THE 2020 ACM INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND UBIQUITOUS COMPUTING AND PROCEEDINGS OF THE 2020 ACM INTERNATIONAL SYMPOSIUM ON WEARABLE COMPUTERS, 2020, : 650 - 656
  • [39] Perspectives on the Calibration and Validation of Low-Cost Air Quality Sensors
    Ottosen, Thor-Bjorn
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2021, 55 (19) : 12773 - 12775
  • [40] Low-Cost Urban Air Quality Monitoring with Mosaic
    Guan, Gaoyang
    Chen, Yuan
    Guo, Kai
    Gao, Yi
    Dong, Wei
    2016 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS), 2016,