Calibration of CO, NO2, and O3 Using Airify: A Low-Cost Sensor Cluster for Air Quality Monitoring

被引:23
|
作者
Ionascu, Marian-Emanuel [1 ]
Castell, Nuria [2 ]
Boncalo, Oana [1 ]
Schneider, Philipp [2 ]
Darie, Marius [3 ]
Marcu, Marius [1 ]
机构
[1] Politehn Univ Timisoara, Fac Automat & Comp, Timisoara 300223, Romania
[2] Norwegian Inst Air Res NILU, N-2007 Kjeller, Norway
[3] Natl Inst Res & Dev Mine Safety & Protect Explos, Petrosani 332047, Romania
关键词
air pollution sensors; air quality monitoring; data quality; electrochemical sensors; low-cost sensors; sensor calibration; PERFORMANCE EVALUATION; FIELD CALIBRATION; AVAILABLE SENSORS; PART; MICROSENSORS; MODEL;
D O I
10.3390/s21237977
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
During the last decade, extensive research has been carried out on the subject of low-cost sensor platforms for air quality monitoring. A key aspect when deploying such systems is the quality of the measured data. Calibration is especially important to improve the data quality of low-cost air monitoring devices. The measured data quality must comply with regulations issued by national or international authorities in order to be used for regulatory purposes. This work discusses the challenges and methods suitable for calibrating a low-cost sensor platform developed by our group, Airify, that has a unit cost five times less expensive than the state-of-the-art solutions (approximately euro1000). The evaluated platform can integrate a wide variety of sensors capable of measuring up to 12 parameters, including the regulatory pollutants defined in the European Directive. In this work, we developed new calibration models (multivariate linear regression and random forest) and evaluated their effectiveness in meeting the data quality objective (DQO) for the following parameters: carbon monoxide (CO), ozone (O-3), and nitrogen dioxide (NO2). The experimental results show that the proposed calibration managed an improvement of 12% for the CO and O-3 gases and a similar accuracy for the NO2 gas compared to similar state-of-the-art studies. The evaluated parameters had different calibration accuracies due to the non-identical levels of gas concentration at which the sensors were exposed during the model's training phase. After the calibration algorithms were applied to the evaluated platform, its performance met the DQO criteria despite the overall low price level of the platform.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Reliable Low-Cost Air Quality Monitoring Using Off-The-Shelf Sensors and Statistical Calibration
    Drajic, Dejan D.
    Gligoric, Nenad R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2020, 26 (02) : 32 - 41
  • [22] Field calibration of a cluster of low-cost available sensors for air quality monitoring. Part A: Ozone and nitrogen dioxide
    Spinelle, Laurent
    Gerboles, Michel
    Villani, Maria Gabriella
    Aleixandre, Manuel
    Bonavitacola, Fausto
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 215 : 249 - 257
  • [23] Design of air quality monitoring networks and its application to NO2 and O3 in Cordova, Spain
    Lozano, Antonio
    Usero, Jose
    Vanderlinden, Eva
    Raez, Juan
    Contreras, Juan
    Navarrete, Benito
    El Bakouri, Hicham
    MICROCHEMICAL JOURNAL, 2009, 93 (02) : 211 - 219
  • [24] On the Security and Data Integrity of Low-Cost Sensor Networks for Air Quality Monitoring
    Luo, Lan
    Zhang, Yue
    Pearson, Bryan
    Ling, Zhen
    Yu, Haofei
    Fu, Xinwen
    SENSORS, 2018, 18 (12)
  • [25] Development of Air Quality Boxes Based on Low-Cost Sensor Technology for Ambient Air Quality Monitoring
    Gaebel, Paul
    Koller, Christian
    Hertig, Elke
    SENSORS, 2022, 22 (10)
  • [26] Assessing and monitoring air quality in cities and urban areas with a portable, modular and low-cost sensor station: calibration challenges
    Alvarado, M. Tarazona
    Salamanca-Coy, J. L.
    Forero-Gutierrez, K.
    Nunez, L. A.
    Pisco-Guabave, J.
    Escobar-Diaz, Fr.
    Sierra-Porta, D.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2024, 45 (17) : 5713 - 5736
  • [27] HypeAIR: A novel framework for real-time low-cost sensor calibration for air quality monitoring in smart cities
    Bachechi, Chiara
    Rollo, Federica
    Po, Laura
    ECOLOGICAL INFORMATICS, 2024, 81
  • [28] Calibration of a cluster of low-cost sensors for the measurement of air pollution in ambient air
    Spinelle, Laurent
    Gerboles, Michel
    Villani, Maria Gabriella
    Aleixandre, Manuel
    Bonavitacola, Fausto
    2014 IEEE SENSORS, 2014, : 21 - 24
  • [29] Robust Calibration for Low-Cost Air Quality Sensors using Historical Data
    Li, Guodong
    Liu, Xinyu
    Wu, Zhiyuan
    Wang, Yue
    Zhang, Lin
    2020 19TH ACM/IEEE INTERNATIONAL CONFERENCE ON INFORMATION PROCESSING IN SENSOR NETWORKS (IPSN 2020), 2020, : 349 - 350
  • [30] Poster: Air Quality Monitoring using Low-cost Sensing Devices
    Ghosh, Arindam
    Mondal, Sandip
    Saha, Mousumi
    Saha, Sujoy
    Nandi, Subrata
    MOBISYS'16: COMPANION COMPANION PUBLICATION OF THE 14TH ANNUAL INTERNATIONAL CONFERENCE ON MOBILE SYSTEMS, APPLICATIONS, AND SERVICES, 2016, : 27 - 27