Preservation of hearing in cochlear implant surgery: Advantages of combined electrical and acoustical speech processing

被引:356
|
作者
Gantz, BJ
Turner, C
Gfeller, KE
Lowder, MW
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, Dept Otolaryngol Head & Neck Surg, Iowa City, IA USA
[2] Univ Iowa, Dept Speech Pathol & Audiol, Iowa City, IA 52242 USA
[3] Univ Iowa, Sch Music, Iowa City, IA 52242 USA
来源
LARYNGOSCOPE | 2005年 / 115卷 / 05期
关键词
Hearing Preservation; cochlear implant; hybrid cochlear implant; hearing in noise;
D O I
10.1097/01.MLG.0000157695.07536.D2
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis. This study documents the importance of preserving residual low-frequency acoustic hearing as those with more residual hearing are selected for cochlear implantation. Surgical strategies used for hearing preservation with a short hybrid cochlear implant are outlined. The benefits of preserved residual low-frequency hearing, improved word understanding in noise, and music appreciation are described. Study Design: Multicenter, prospective, single-subject design. Methods. Records were reviewed of 21 individuals participating in an Food and Drug Administration (FDA) feasibility clinical trial who have received an Iowa/Nucleus 10 mm electrode. A second group of subjects receiving implants at the University of Iowa that have used the 10 mm device between 2 years and 6 months were also reviewed. Outcome measures included standardized tests of monosyllabic word understanding, spondees in noise, and common melody recognition. Results. Low-frequency hearing was maintained in all individuals immediately postoperative. One subject lost hearing at 2.5 months postoperative after a viral infection. The group has averaged a loss of -9 dB low-frequency acoustic hearing between 125 and 1,000 Hz. Monosyllabic word understanding scores at 6 months for a group being followed for an FDA clinical trial using the implant plus hearing aids was 69% correct. For the long-term group receiving implants at Iowa, monosyllabic word understanding in those who have used the device between 6 months and 2 years is 79%. Other important findings include improved recognition of speech in noise (9 dB improvement) as compared with standard cochlear implant recipients who were matched for speech recognition in quiet and near normal recognition of common melodies. Conclusion. The surgical strategies outlined have been successful in preservation of low-frequency hearing in 96% of individuals. Combined electrical and acoustical speech processing has enabled this group of volunteers to gain improved word understanding as compared with their preoperative hearing with bilateral hearing aids and a group of individuals receiving a standard cochlear implant with similar experience with their device. The improvement of speech in noise and melody recognition is attributed to the ability to distinguish fine pitch differences as the result of preserved residual low-frequency acoustic hearing. Preservation of low-frequency acoustic hearing is important for improving speech in noise and music appreciation for the hearing impaired, both of which are important in real-life situations.
引用
收藏
页码:796 / 802
页数:7
相关论文
共 50 条
  • [21] Predicting Acoustic Hearing Preservation Following Cochlear Implant Surgery Using Machine Learning
    Zeitler, Daniel M.
    Buchlak, Quinlan D.
    Ramasundara, Savindi
    Farrokhi, Farrokh
    Esmaili, Nazanin
    LARYNGOSCOPE, 2024, 134 (02): : 926 - 936
  • [22] Preservation of Residual Hearing After Cochlear Implant Surgery With Deep Insertion Electrode Arrays
    Sierra, Cristina
    Calderon, Manuela
    Barcena, Eduardo
    Tisaire, Alexandra
    Raboso, Eduardo
    OTOLOGY & NEUROTOLOGY, 2019, 40 (04) : E373 - E380
  • [23] Clinical, surgical, and electrical factors impacting residual hearing in cochlear implant surgery
    Eshraghi, Adrien A.
    Ahmed, Jamal
    Krysiak, Eric
    Ila, Kadri
    Ashman, Peter
    Telischi, Fred F.
    Angeli, Simon
    Prentiss, Sandra
    Martinez, Diane
    Valendia, Sandra
    ACTA OTO-LARYNGOLOGICA, 2017, 137 (04) : 384 - 388
  • [24] Feasibility of hearing preservation for residual hearing with longer cochlear implant electrodes
    Moteki, Hideaki
    Nishio, Shin-Ya
    Miyagawa, Maiko
    Tsukada, Keita
    Noguchi, Yoshihiro
    Usami, Shin-Ichi
    ACTA OTO-LARYNGOLOGICA, 2018, 138 (12) : 1080 - 1085
  • [25] Intra-Cochlear Electrode Position Impacts the Preservation of Residual Hearing in an Animal Model of Cochlear Implant Surgery
    Meuser, Max
    Schwitzer, Susanne
    Thiele, Mario
    Boyle, Patrick
    Ernst, Arne
    Basta, Dietmar
    AUDIOLOGY AND NEUROTOLOGY, 2025, 30 (01) : 34 - 44
  • [26] Cochlear implant: More hearing better speech performance
    Alhabib, Salman F.
    Abdelsamad, Yassin
    Badghaish, Reem S.
    Alzhrani, Farid
    Hagr, Abdulrahman
    Almuhawas, Fida
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 150
  • [27] Residual hearing preservation for cochlear implantation surgery
    Lin, Chung-Ching
    Chiu, Ting
    Chiou, Hong-Ping
    Chang, Chu-Man
    Hsu, Chuan-Jen
    Wu, Hung-Pin
    TZU CHI MEDICAL JOURNAL, 2021, 33 (04): : 359 - 364
  • [28] Long-term results of hearing preservation cochlear implant surgery in patients with residual low frequency hearing
    Moteki, Hideaki
    Nishio, Shin-ya
    Miyagawa, Maiko
    Tsukada, Keita
    Iwasaki, Satoshi
    Usami, Shin-ichi
    ACTA OTO-LARYNGOLOGICA, 2017, 137 (05) : 516 - 521
  • [29] Speech Intelligibility in Children with Cochlear Implant, with Hearing Aids and Normal Hearing
    Ashoori, M.
    Jalilabkenar, S. S.
    Hasanzadeh, S.
    Tajrishi, Pourmohamadreza M.
    ARCHIVES OF REHABILITATION, 2013, 14 (03): : 8 - 15
  • [30] An Individual With Hearing Preservation and Bimodal Hearing Using a Cochlear Implant and Hearing Aids Has Perturbed Sound Localization but Preserved Speech Perception
    Sharma, Snandan
    Mens, Lucas H. M.
    Snik, Ad F. M.
    van Opstal, A. John
    van Wanrooij, Marc M.
    FRONTIERS IN NEUROLOGY, 2019, 10