Measurement of gas hold-up profiles in stirred tank reactors by gamma ray attenuation technique

被引:0
|
作者
Veera, UP
Patwardhan, AW
Joshi, JB [1 ]
机构
[1] Univ Mumbai, Dept Chem Technol, Matunga 400019, Mumbai, India
[2] Univ Twente, Div Chem Technol, IPP, NL-7500 AE Enschede, Netherlands
来源
关键词
gas hold-up; gamma ray tomography; stirred reactors; process design;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Gas hold-up is one of the most important hydrodynamic characteristics that is needed for performance estimation, design and scale-up of reactors. The performance of large-scale reactors can be reliably evaluated by measuring the gas hold-up in such reactors. In the present work, local gas hold-up in an industrial reactor has been measured with the help of gamma ray tomography. Based on these measurements, an empirical equation has been proposed for the estimation of the gas hold-up distribution. The proposed equation has been validated by comparison with laboratory scale data.
引用
收藏
页码:684 / 688
页数:5
相关论文
共 50 条
  • [41] ULTRASONIC TECHNIQUE FOR CONTROL OF HOLD-UP PROFILES IN MULTISTAGE EXTRACTION COLUMNS.
    Kirou, Vassilios I.
    Tavlarides, Lawrence L.
    Bonnet, Julio C.
    Industrial and Engineering Chemistry Research, 1988, 27 (06): : 1084 - 1086
  • [43] MEASUREMENT OF GAS AND LIQUID FLOWS IN STIRRED-TANK REACTORS WITH MULTIPLE AGITATORS
    MANIKOWSKI, M
    BODEMEIER, S
    LUBBERT, A
    BUJALSKI, W
    NIENOW, AW
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1994, 72 (05): : 769 - 781
  • [44] HOLD-UP AND MASS-TRANSFER IN A 2-PHASE AND 3-PHASE STIRRED TANK REACTOR
    KRALJ, F
    SINCIC, D
    CHEMICAL ENGINEERING SCIENCE, 1984, 39 (03) : 604 - 607
  • [45] EFFECT OF FINE PARTICLES ON GAS HOLD-UP IN 3-PHASE SPARGED REACTORS
    KHARE, AS
    JOSHI, JB
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1990, 44 (01): : 11 - 25
  • [46] LOCAL GAS HOLD-UP IN XANTHAN-GUM-SIMULATED ACTINOMYCES MEDIA IN A STIRRED BIOREACTOR
    VLAEV, SD
    VALEVA, M
    BIOTECHNOLOGY TECHNIQUES, 1994, 8 (03) : 149 - 152
  • [47] AN AVERAGE GAS HOLD-UP AND LIQUID CIRCULATION VELOCITY IN AIRLIFT REACTORS WITH EXTERNAL LOOP
    KEMBLOWSKI, Z
    PRZYWARSKI, J
    DIAB, A
    CHEMICAL ENGINEERING SCIENCE, 1993, 48 (23) : 4023 - 4035
  • [48] Bubble column bioreactors: Comparison with stirred fermenters based on local gas hold-up distribution
    Vlaev, SD
    Fialova, M
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2003, 81 (3-4): : 535 - 542
  • [49] Gas hold-up and gas-liquid mass transfer in three-phase stirred tank bioreactors with simulated non-Newtonian fermentation broths
    Kawase, Y
    Shimizu, K
    Takada, S
    4TH INTERNATIONAL CONFERENCE ON BIOREACTOR & BIOPROCESS FLUID DYNAMICS, 1997, (25): : 351 - 359
  • [50] Measurement of gas hold-up in gas-liquid flow based on wavelet analysis
    Chen, Wen-Yi
    Jiang, Nan
    Wang, Zhen-Dong
    Jiliang Xuebao/Acta Metrologica Sinica, 2008, 29 (01): : 51 - 53