Measurement of gas hold-up profiles in stirred tank reactors by gamma ray attenuation technique

被引:0
|
作者
Veera, UP
Patwardhan, AW
Joshi, JB [1 ]
机构
[1] Univ Mumbai, Dept Chem Technol, Matunga 400019, Mumbai, India
[2] Univ Twente, Div Chem Technol, IPP, NL-7500 AE Enschede, Netherlands
来源
关键词
gas hold-up; gamma ray tomography; stirred reactors; process design;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Gas hold-up is one of the most important hydrodynamic characteristics that is needed for performance estimation, design and scale-up of reactors. The performance of large-scale reactors can be reliably evaluated by measuring the gas hold-up in such reactors. In the present work, local gas hold-up in an industrial reactor has been measured with the help of gamma ray tomography. Based on these measurements, an empirical equation has been proposed for the estimation of the gas hold-up distribution. The proposed equation has been validated by comparison with laboratory scale data.
引用
收藏
页码:684 / 688
页数:5
相关论文
共 50 条
  • [31] Quantitative measurement of gas hold-up distribution in a stirred chemical reactor using X-ray cone-beam computed tomography
    Boden, Stephan
    Bieberle, Martina
    Hampel, Uwe
    CHEMICAL ENGINEERING JOURNAL, 2008, 139 (02) : 351 - 362
  • [32] CFD simulation of sparger design and height to diameter ratio on gas hold-up profiles in bubble column reactors
    Dhotre, MT
    Ekambara, K
    Joshi, JB
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 28 (05) : 407 - 421
  • [33] Flow Pattern, Mixing, Gas Hold-Up and Mass Transfer Coefficient of Triple-Impeller Configurations in Stirred Tank Bioreactors
    Xie, Minghui
    Xia, Jianye
    Zhou, Zhen
    Chu, Ju
    Zhuang, Yingping
    Zhang, Siliang
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (14) : 5941 - 5953
  • [34] On-line gas hold-up measurement in flotation columns
    Pérez-Garibay, R
    De Villar, R
    CANADIAN METALLURGICAL QUARTERLY, 1999, 38 (02) : 141 - 148
  • [35] AN ULTRASONIC TECHNIQUE FOR CONTROL OF HOLD-UP PROFILES IN MULTISTAGE EXTRACTION COLUMNS
    KIROU, VI
    TAVLARIDES, LL
    BONNET, JC
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1988, 27 (06) : 1085 - 1086
  • [36] Gas hold-up and liquid circulation velocity in gas-liquid-solid airlift reactors
    Popovic, MK
    Kiefner, AW
    Bajpai, RK
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2004, 82 (06): : 1273 - 1274
  • [37] Effect of the ejector configuration on the gas suction rate and gas hold-up in ejector loop reactors
    Inst of Chemical Technology, Prague, Czech Republic
    Chem Eng Sci, 11 (1701-1713):
  • [38] Gas hold-up and mass transfer in gas-lift reactors operated at elevated pressures
    Letzel, M
    Stankiewicz, A
    CHEMICAL ENGINEERING SCIENCE, 1999, 54 (21) : 5153 - 5157
  • [39] A comparative study of gas hold-up, bubble size, interfacial area and mass transfer coefficients in stirred gas-liquid reactors and bubble columns
    Bouaifi, M
    Hebrard, G
    Bastoul, D
    Roustan, M
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2001, 40 (02) : 97 - 111
  • [40] Low-resolution gamma-ray measurements of process hold-up
    Sprinkle, JK
    Cole, R
    Collins, ML
    Hsue, ST
    Russo, PA
    Siebelist, R
    Smith, HA
    Ceo, RN
    Smith, SE
    APPLIED RADIATION AND ISOTOPES, 1997, 48 (10-12) : 1529 - 1534