Dose reduction in paediatric cranial CT via iterative reconstruction: a clinical study in 78 patients

被引:8
|
作者
Kaul, D. [1 ,2 ,3 ,4 ]
Kahn, J. [1 ,2 ]
Huizing, L. [1 ,2 ]
Wiener, E. [1 ,2 ]
Boening, G. [1 ,2 ]
Renz, D. M. [5 ]
Streitparth, F. [1 ,2 ]
机构
[1] Charite Sch Med, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Univ Hosp, Charitepl 1, D-10117 Berlin, Germany
[3] Charite Sch Med, Dept Radiat Oncol, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Univ Hosp, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Jena Univ Hosp, Dept Radiol, Erlanger Allee 101, D-07747 Jena, Germany
关键词
FILTERED BACK-PROJECTION; IMAGE QUALITY; HEAD CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER; RISK;
D O I
10.1016/j.crad.2016.06.115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess how adaptive statistical iterative reconstruction (ASIR) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT) in children. MATERIALS AND METHODS: Non-contrast cranial CT acquired in 78 paediatric patients (age 0-12 years) were evaluated. The images were acquired and processed using four different protocols: Group A (control): 120 kV, filtered back projection (FBP), n=18; Group B: 100 kV, FBP, n=22; Group C: 100 kV, scan and reconstruction performed with 20% ASIR, n=20; Group D1: 100 kV, scan and reconstruction performed with 30% ASIR, n=18; Group D2: raw data from Group D1 reconstructed using a blending of 40% ASIR and 60% FBP, n=18. The effective dose was calculated and the image quality was assessed quantitatively and qualitatively. RESULTS: Compared to Group A, Groups C and D1/D2 showed a significant reduction of the dose-length product (DLP) by 34.4% and 64.4%, respectively. All experimental groups also showed significantly reduced qualitative levels of noise, contrast, and overall diagnosability. Diagnosis-related confidence grading showed Group C to be adequate for everyday clinical practice. Quantitative measures of Groups B and C were comparable to Group A with only few parameters compromised. Quantitative scores in Groups D1 and D2 were mainly lower compared to Group A, with Group D2 performing better than Group Dl. Group D2 was considered adequate for follow-up imaging of severe acute events such as bleeding or hydrocephalus. DISCUSSION: The use of ASIR combined with low tube voltage may reduce radiation significantly while maintaining adequate image quality in non-contrast paediatric cCT. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1168 / 1177
页数:10
相关论文
共 50 条
  • [21] Dose reduction and image quality in CT examinations using an iterative reconstruction algorithm: a phantom study
    Guariglia, S.
    Meliado, G.
    Zivelonghi, E.
    Pinali, L.
    Montemezzi, S.
    Cavedon, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (04):
  • [22] Model-based iterative reconstruction in paediatric head computed tomography: a pilot study on dose reduction in children
    Atri, Pardeep K.
    Sodhi, Kushaljit S.
    Bhatia, Anmol
    Saxena, Akshay K.
    Khandelwal, Niranjan
    Singhi, Pratibha
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E504 - E510
  • [23] Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction
    Fahimian, Benjamin P.
    Zhao, Yunzhe
    Huang, Zhifeng
    Fung, Russell
    Mao, Yu
    Zhu, Chun
    Khatonabadi, Maryam
    DeMarco, John J.
    Osher, Stanley J.
    McNitt-Gray, Michael F.
    Miao, Jianwei
    MEDICAL PHYSICS, 2013, 40 (03)
  • [24] Radiation Dose Reduction by Using CT with Iterative Model Reconstruction in Patients with Pulmonary Invasive Fungal Infection
    Yan, Chenggong
    Xu, Jun
    Liang, Chunyi
    Wei, Qi
    Wu, Yuankui
    Xiong, Wei
    Zheng, Huan
    Xu, Yikai
    RADIOLOGY, 2018, 288 (01) : 285 - 292
  • [25] Possibilities of dose reduction during CT imaging by application of iterative image reconstruction
    Bajzik Gabor
    Toth Anetti
    Donko Tamas
    Kovacs Peter
    Sipos David
    Pandur Attila Andras
    Moizs Mariann
    Hadjiev Janaki
    Repa Imre
    Kovacs Arpad
    ORVOSI HETILAP, 2019, 160 (35) : 1387 - 1394
  • [26] Investigation of Renal CT Dose Reduction by Using Model Based Iterative Reconstruction
    Page, L.
    Kundra, V.
    Rong, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Niesten, Joris M.
    van der Schaaf, Irene C.
    Riordan, Alan J.
    de Jong, Hugo W. A. M.
    Horsch, Alexander D.
    Eijspaart, Daniel
    Smit, Ewoud J.
    Mali, Willem P. T. M.
    Velthuis, Birgitta K.
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 484 - 493
  • [28] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987
  • [29] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [30] Optimization Gap: Iterative Reconstruction Does Not Deliver Actual CT Dose Reduction in a Large, Diverse Fleet of Clinical CT Scanners
    Bell, J.
    Smitherman, C.
    Petrone, T.
    Moloney, W.
    Jordan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E262 - E263