Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:40
|
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
  • [1] Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction
    Joris M. Niesten
    Irene C. van der Schaaf
    Alan J. Riordan
    Hugo W. A. M. de Jong
    Alexander D. Horsch
    Daniel Eijspaart
    Ewoud J. Smit
    Willem P. T. M. Mali
    Birgitta K. Velthuis
    European Radiology, 2014, 24 : 484 - 493
  • [2] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    RADIOLOGY, 2012, 263 (02) : 537 - 546
  • [3] Reduction in radiation dose with reconstruction technique in the brain perfusion CT
    Kim, H. J.
    Lee, H. K.
    Song, H.
    Ju, M. S.
    Dong, K. R.
    Chung, W. K.
    Cho, M. S.
    Cho, J. H.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (12): : 918 - 926
  • [4] Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms
    Weir, V.
    Zhang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368
  • [5] Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method
    Tao, Yinghua
    Chen, Guang-Hong
    Hacker, Timothy A.
    Raval, Amish N.
    Van Lysel, Michael S.
    Speidel, Michael A.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [6] Radiation Dose Reduction in Temporal Bone CT with Iterative Reconstruction Technique
    Niu, Y. T.
    Mehta, D.
    Zhang, Z. R.
    Zhang, Y. X.
    Liu, Y. F.
    Kang, T. L.
    Xian, J. F.
    Wang, Z. C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1020 - 1026
  • [7] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [8] Reduction of scan duration and radiation dose in cerebral CT perfusion imaging of acute stroke using a recurrent neural network
    Moghari, Mahdieh Dashtbani
    Sanaat, Amirhossein
    Young, Noel
    Moore, Krystal
    Zaidi, Habib
    Evans, Andrew
    Fulton, Roger R.
    Kyme, Andre Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (16):
  • [9] Radiation Dose Reduction in CT Myocardial Perfusion Imaging Using SMART-RECON
    Li, Yinsheng
    Speidel, Michael A.
    Francois, Christopher J.
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (12) : 2557 - 2568
  • [10] Radiation Dose Reduction in Paranasal Sinus CT Using Model-Based Iterative Reconstruction
    Hoxworth, J. M.
    Lal, D.
    Fletcher, G. P.
    Patel, A. C.
    He, M.
    Paden, R. G.
    Hara, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (04) : 644 - 649