Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:39
|
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
  • [31] Patient radiation dose reduction using a commercial iterative reconstruction technique package
    Sulieman, A.
    Adam, H.
    Elnour, A.
    Tamam, N.
    Alhaili, A.
    Alkhorayef, M.
    Alghamdi, S.
    Khandaker, Mayeen Uddin
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 178
  • [32] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Othman, Ahmed E.
    Brockmann, Carolin
    Yang, Zepa
    Kim, Changwon
    Afat, Saif
    Pjontek, Rastislav
    Nikobashman, Omid
    Brockmann, Marc A.
    Kim, Jong Hyo
    Wiesmann, Martin
    EUROPEAN RADIOLOGY, 2015, 25 (12) : 3415 - 3422
  • [33] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikobashman
    Marc A. Brockmann
    Jong Hyo Kim
    Martin Wiesmann
    European Radiology, 2015, 25 : 3415 - 3422
  • [34] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Karolin J. Paprottka
    Karina Kupfer
    Vivian Schultz
    Meinrad Beer
    Claus Zimmer
    Thomas Baum
    Jan S. Kirschke
    Nico Sollmann
    Scientific Reports, 13
  • [35] Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom study
    Dodge, Cristina T.
    Tamm, Eric P.
    Cody, Dianna D.
    Liu, Xinming
    Jensen, Corey T.
    Wei, Wei
    Kundra, Vikas
    Rong, X. John
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 511 - 531
  • [36] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Paprottka, Karolin J.
    Kupfer, Karina
    Schultz, Vivian
    Beer, Meinrad
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [37] Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot Study
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Gilman, Matthew D.
    Hsieh, Jiang
    Pien, Homer H.
    Digumarthy, Subba R.
    Shepard, Jo-Anne O.
    RADIOLOGY, 2011, 259 (02) : 565 - 573
  • [38] Feasibility of radiation dose reduction with iterative reconstruction in abdominopelvic CT for patients with inappropriate arm positioning
    Seo, Nieun
    Chung, Yong Eun
    An, Chansik
    Choi, Jin-Young
    Park, Mi-Suk
    Kim, Myeong-Jin
    PLOS ONE, 2018, 13 (12):
  • [39] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [40] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1613 - 1623