Radiation dose reduction in cerebral CT perfusion imaging using iterative reconstruction

被引:40
|
作者
Niesten, Joris M. [1 ]
van der Schaaf, Irene C. [1 ]
Riordan, Alan J. [1 ]
de Jong, Hugo W. A. M. [1 ]
Horsch, Alexander D. [2 ]
Eijspaart, Daniel [1 ]
Smit, Ewoud J. [1 ]
Mali, Willem P. T. M. [1 ]
Velthuis, Birgitta K. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3584 CX Utrecht, Netherlands
[2] Rijnstate Hosp, Dept Radiol, Arnhem, Netherlands
关键词
Cerebral perfusion; Stroke; Infarction; Computed tomography; Radiation dose; TEMPORAL RESOLUTION; ISCHEMIC-STROKE; PARAMETERS; ALGORITHMS; ACCURACY; QUALITY; VOLUME; NOISE;
D O I
10.1007/s00330-013-3042-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To investigate whether iterative reconstruction (IR) in cerebral CT perfusion (CTP) allows for 50 % dose reduction while maintaining image quality (IQ). A total of 48 CTP examinations were reconstructed into a standard dose (150 mAs) with filtered back projection (FBP) and half-dose (75 mAs) with two strengths of IR (middle and high). Objective IQ (quantitative perfusion values, contrast-to-noise ratio (CNR), penumbra, infarct area and penumbra/infarct (P/I) index) and subjective IQ (diagnostic IQ on a four-point Likert scale and overall IQ binomial) were compared among the reconstructions. Half-dose CTP with high IR level had, compared with standard dose with FBP, similar objective (grey matter cerebral blood volume (CBV) 4.4 versus 4.3 mL/100 g, CNR 1.59 versus 1.64 and P/I index 0.74 versus 0.73, respectively) and subjective diagnostic IQ (mean Likert scale 1.42 versus 1.49, respectively). The overall IQ in half-dose with high IR level was scored lower in 26-31 %. Half-dose with FBP and with the middle IR level were inferior to standard dose with FBP. With the use of IR in CTP imaging it is possible to examine patients with a half dose without significantly altering the objective and diagnostic IQ. The standard dose with FBP is still preferable in terms of subjective overall IQ in about one quarter of patients. Key points Computed tomography perfusion (CTP) is increasingly important in ischaemia imaging. Radiation exposure of CTP is a drawback. Iterative reconstruction (IR) allows reduction of radiation dose in unenhanced head CT. CTP IR enables 50 % dose reduction without altering objective and diagnostic quality.
引用
收藏
页码:484 / 493
页数:10
相关论文
共 50 条
  • [21] Advanced Modeled Iterative Reconstruction (ADMIRE) Facilitates Radiation Dose Reduction in Abdominal CT
    Ellmann, Stephan
    Kammerer, Ferdinand
    Allmendinger, Thomas
    Hammon, Matthias
    Janka, Rolf
    Lell, Michael
    Uder, Michael
    Kramer, Manuel
    ACADEMIC RADIOLOGY, 2018, 25 (10) : 1277 - 1284
  • [22] Radiation Dose Reduction at Pediatric CT: Use of Low Tube Voltage and Iterative Reconstruction
    Nagayama, Yasunori
    Oda, Seitaro
    Nakaura, Takeshi
    Tsuji, Akinori
    Urata, Joji
    Furusawa, Mitsuhiro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Kidoh, Masafumi
    Yamashita, Yasuyuki
    RADIOGRAPHICS, 2018, 38 (05) : 1421 - +
  • [23] Iterative reconstruction for image enhancement and dose reduction in diagnostic cone beam CT imaging
    Matenine, Dmitri
    Schmittbuhl, Matthieu
    Bedwani, Stephane
    Despres, Philippe
    de Guise, Jacques A.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (05) : 805 - 819
  • [24] Monitoring Radiation Dose in Cerebral CT Perfusion Exams
    Lu, Z.
    So, J.
    Dutta, A.
    Nickoloff, E.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [25] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [26] Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study
    den Harder, Annemarie M.
    Willemink, Martin J.
    van Doormaal, Pieter J.
    Wessels, Frank J.
    Lock, M. T. W. T.
    Schilham, Arnold M. R.
    Budde, Ricardo P. J.
    Leiner, Tim
    de Jong, Pim A.
    EUROPEAN RADIOLOGY, 2018, 28 (01) : 143 - 150
  • [27] Can Iterative Reconstruction Improve Imaging Quality for Lower Radiation CT Perfusion? Initial Experience
    Lin, C. J.
    Wu, T. H.
    Lin, C. H.
    Hung, S. C.
    Chiu, C. F.
    Liu, M. -J.
    Teng, M. M. H.
    Chang, F. C.
    Guo, W. Y.
    Chang, C. Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) : 1516 - 1521
  • [28] Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study
    Annemarie M. den Harder
    Martin J. Willemink
    Pieter J. van Doormaal
    Frank J. Wessels
    M. T. W. T. Lock
    Arnold M. R. Schilham
    Ricardo P. J. Budde
    Tim Leiner
    Pim A. de Jong
    European Radiology, 2018, 28 : 143 - 150
  • [29] Investigation of Renal CT Dose Reduction by Using Model Based Iterative Reconstruction
    Page, L.
    Kundra, V.
    Rong, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] Hepatic CT perfusion measurements: A feasibility study for radiation dose reduction using new image reconstruction method
    Negi, Noriyuki
    Yoshikawa, Takeshi
    Ohno, Yoshiharu
    Somiya, Yuichiro
    Sekitani, Toshinori
    Sugihara, Naoki
    Koyama, Hisanobu
    Kanda, Tomonori
    Kanata, Naoki
    Murakami, Tohru
    Kawamitsu, Hideaki
    Sugimura, Kazuro
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3048 - 3054