Pulsed radiofrequency glow discharge time of flight mass spectrometry for coated glass analysis

被引:16
|
作者
Bouza, Marcos [1 ]
Pereiro, Rosario [1 ]
Bordel, Nerea [2 ]
Sanz-Medel, Alfredo [1 ]
Fernandez, Beatriz [1 ]
机构
[1] Univ Oviedo, Fac Chem, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
[2] Univ Oviedo, Dept Phys, E-33006 Oviedo, Spain
关键词
DEPTH-PROFILE ANALYSIS;
D O I
10.1039/c4ja00474d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical potential of radiofrequency pulsed glow discharge time of flight mass spectrometry (rf-PGD-ToFMS) is investigated for quantitative depth profiling analysis of glasses and thin conductive and non-conductive layers on glasses. PGD in combination with ToFMS can allow the reduction or even removal of spectral interferences by selecting a proper GD pulse interval. Thus, discrimination of potential polyatomic interferences for several analytes (e.g., Si-28(+), K-39(+), Ca-44(+), and Ti-48(+)) was investigated by selecting appropriate time positions along the GD pulse profile. In this paper, the determination of compositional depth profiles of coated glasses was performed by resorting to a multi-matrix calibration procedure. For this purpose, conductive as well as non-conductive certified reference materials were employed to build the analytical calibration curves. Results show that rf-PGD-ToFMS allows us to discriminate the different layers of the samples and the nominal values for element concentrations and layer thicknesses were in agreement with experimental results obtained using the proposed quantification strategy. Moreover, the capability of rf-PGD-ToFMS to provide a full mass spectrum every 33 mu s enable the identification of unexpected elements which can be present as contaminants in very thin layers (e.g. Cd, Sn, Te and Sb).
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [31] Gas chromatography coupled to tunable pulsed glow discharge time-of-flight mass spectrometry for environmental analysis
    Sola-Vazquez, Auristela
    Lara-Gonzalo, Azucena
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYST, 2010, 135 (05) : 987 - 993
  • [32] Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge
    Ganeev, Aleksander
    Gubal, Anna
    Korotetski, Boris
    Bogdanova, Oksana
    Burakov, Boris
    Titova, Anna
    Solovyev, Nikolay
    Ivanenko, Natalya
    Drobyshev, Evgenii
    Iakovleva, Evgenia
    Sillanpaa, Mika
    MICROCHEMICAL JOURNAL, 2017, 132 : 286 - 292
  • [33] Microsecond-pulsed glow discharge time-of-flight mass spectrometry: Analytical advantages
    Hang, W
    Baker, C
    Smith, BW
    Winefordner, JD
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (02) : 143 - 149
  • [34] Microsecond-pulsed Grimm glow discharge as a source for time-of-flight mass spectrometry
    Yang, CL
    Mohill, M
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (09) : 1255 - 1260
  • [35] A novel gas sampling introduction interface for fast analysis of volatile organic compounds using radiofrequency pulsed glow discharge time of flight mass spectrometry
    Fandino, J.
    Bouza, M.
    Pisonero, J.
    Blanco, D.
    Sanz-Medel, A.
    Bordel, N.
    ANALYTICA CHIMICA ACTA, 2018, 1038 : 59 - 66
  • [36] A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses
    Jorge Pisonero
    José Manuel Costa
    Rosario Pereiro
    Nerea Bordel
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2004, 379 : 658 - 667
  • [37] A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses
    Pisonero, J
    Costa, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) : 658 - 667
  • [38] Evaluation of pulsed radiofrequency glow discharge time-of-flight mass spectrometry for precious metal determination in lead fire assay buttons
    Compernolle, Sien
    Pisonero, Jorge
    Bordel, Nerea
    Wambeke, Dorine
    De Raedt, Ine
    Kimpe, Kristof
    Sanz-Medel, Alfredo
    Vanhaecke, Frank
    ANALYTICA CHIMICA ACTA, 2011, 701 (02) : 129 - 133
  • [39] Spectroscopic evaluation of a compact magnetically boosted radiofrequency glow discharge for time-of-flight mass spectrometry
    P. Vega
    J. Pisonero
    N. Bordel
    A. Tempez
    M. Ganciu
    A. Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2009, 394 : 373 - 382
  • [40] Spectroscopic evaluation of a compact magnetically boosted radiofrequency glow discharge for time-of-flight mass spectrometry
    Vega, P.
    Pisonero, J.
    Bordel, N.
    Tempez, A.
    Ganciu, M.
    Sanz-Medel, A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (01) : 373 - 382