Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS

被引:5
|
作者
Shuai, Kang [1 ,2 ]
Li, Weiqiang [1 ,2 ,3 ]
Hui, Hejiu [1 ,2 ,3 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, Lunar & Planetary Sci, Nanjing 210023, Peoples R China
[3] CAS Ctr Excellence Comparat Planetol, Hefei 230026, Peoples R China
关键词
PLASMA-MASS SPECTROMETRY; FRACTIONATION; CALCIUM; PRECISE; ANOMALIES; SAMPLE; EARTH; ZN; CU;
D O I
10.1021/acs.analchem.9b04160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Absolute isotopic ratios are required for isobaric interference corrections, spike calibrations, and isotopic analysis by external normalization methods. However, high-precision natural isotopic abundance data are lacking for many elements, particularly those with less than four isotopes or having isobaric isotopes with other elements. In this study, we developed a method for absolute isotope ratio analysis, which integrates the concept of the double-spike method with isotopic analysis of element pairs that have isobaric isotopes. Using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS), the isotopic composition of a sample can be derived by measuring a series of mixtures of the sample and a spike element that has an isobaric isotope with the element being analyzed. We applied this method to five pairs of elements (Ca-Ti, V-Ti, Cr-Ti, Ni-Zn, and In-Sn) and obtained the absolute isotopic ratios for Ca, V, Cr, Ni, and In, as well as the relative Ca isotopic composition. By simultaneous measurement of Ti and Ca isotopes, a quantitative relationship between the instrumental mass fractionation factors and element masses was developed. After correcting for the difference in instrumental mass fractionation factors, the obtained absolute ratios agree well with the literature data and have per mil level accuracy. This method has considerable potential in measuring the absolute isotopic ratios of elements that have isobaric isotope with other elements. Such precisely determined absolute isotopic ratios and the relationship between the instrumental mass fractionation factors and elemental masses will improve isobaric interference corrections, particularly when chemical purification is imperfect or during laser ablation analysis.
引用
收藏
页码:4820 / 4828
页数:9
相关论文
共 50 条
  • [41] A novel purification method for high precision measurement of Ni isotopes by double spike MC-ICP-MS
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    Han, Guilin
    Tan, Decan
    Wang, Shui-Jiong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1639 - 1651
  • [42] Chromium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Ponter, Simon
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (07) : 1464 - 1471
  • [43] Cadmium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Ohlander, Bjorn
    Ingri, Johan
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1570 - 1584
  • [44] A critical review on isotopic fractionation correction methods for accurate isotope amount ratio measurements by MC-ICP-MS
    Yang, Lu
    Tong, Shuoyun
    Zhou, Lian
    Hu, Zhaochu
    Mester, Zoltan
    Meija, Juris
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (11) : 1849 - 1861
  • [45] Rapid isotopic analysis of uranium particles by laser ablation MC-ICP-MS
    Wimpenny, Josh
    Samperton, Kyle M.
    Sotorrio, Pedro
    Wellons, Matthew S.
    Scott, Spencer M.
    Willingham, David
    Knight, Kim
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (04) : 827 - 840
  • [46] Copper Isotopic Analysis in Geological and Biological Reference Materials by MC-ICP-MS
    Sullivan, Kaj
    Layton-Matthews, Daniel
    Leybourne, Matthew
    Kidder, James
    Mester, Zoltan
    Yang, Lu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (02) : 349 - 362
  • [47] Magnesium isotopic composition of igneous rock standards measured by MC-ICP-MS
    Huang, Fang
    Glessner, Justin
    Ianno, Adam
    Lundstrom, Craig
    Zhang, Zhaofeng
    CHEMICAL GEOLOGY, 2009, 268 (1-2) : 15 - 23
  • [48] In situ Ti isotopic analysis by femtosecond laser ablation MC-ICP-MS
    Huang, Chao
    Wang, Hao
    Xie, Liewen
    Nie, Nicole X.
    Yang, Yueheng
    Zhao, Xinmiao
    Li, Jin
    Tian, Heng-Ci
    Wu, Shitou
    Xu, Lei
    Yang, Jinhui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (10) : 2165 - 2175
  • [49] Precise analysis of antimony isotopic composition in geochemical materials by MC-ICP-MS
    Sun, Guangyi
    Wu, Yunjie
    Feng, Xinbin
    Wu, Xian
    Li, Xinyu
    Deng, Qianwen
    Wang, Feiyue
    Fu, Xuewu
    CHEMICAL GEOLOGY, 2021, 582
  • [50] A rapid method of simultaneous chromatographic purification of Li and Mg for isotopic analyses using MC-ICP-MS
    Zhang, Wei
    Tanaka, Ryoji
    Kitagawa, Hiroshi
    Bohlin, Madeleine
    Nakamura, Eizo
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 480