Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS

被引:5
|
作者
Shuai, Kang [1 ,2 ]
Li, Weiqiang [1 ,2 ,3 ]
Hui, Hejiu [1 ,2 ,3 ]
机构
[1] Nanjing Univ, Sch Earth Sci & Engn, State Key Lab Mineral Deposits Res, Nanjing 210023, Peoples R China
[2] Nanjing Univ, Sch Earth Sci & Engn, Lunar & Planetary Sci, Nanjing 210023, Peoples R China
[3] CAS Ctr Excellence Comparat Planetol, Hefei 230026, Peoples R China
关键词
PLASMA-MASS SPECTROMETRY; FRACTIONATION; CALCIUM; PRECISE; ANOMALIES; SAMPLE; EARTH; ZN; CU;
D O I
10.1021/acs.analchem.9b04160
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Absolute isotopic ratios are required for isobaric interference corrections, spike calibrations, and isotopic analysis by external normalization methods. However, high-precision natural isotopic abundance data are lacking for many elements, particularly those with less than four isotopes or having isobaric isotopes with other elements. In this study, we developed a method for absolute isotope ratio analysis, which integrates the concept of the double-spike method with isotopic analysis of element pairs that have isobaric isotopes. Using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS), the isotopic composition of a sample can be derived by measuring a series of mixtures of the sample and a spike element that has an isobaric isotope with the element being analyzed. We applied this method to five pairs of elements (Ca-Ti, V-Ti, Cr-Ti, Ni-Zn, and In-Sn) and obtained the absolute isotopic ratios for Ca, V, Cr, Ni, and In, as well as the relative Ca isotopic composition. By simultaneous measurement of Ti and Ca isotopes, a quantitative relationship between the instrumental mass fractionation factors and element masses was developed. After correcting for the difference in instrumental mass fractionation factors, the obtained absolute ratios agree well with the literature data and have per mil level accuracy. This method has considerable potential in measuring the absolute isotopic ratios of elements that have isobaric isotope with other elements. Such precisely determined absolute isotopic ratios and the relationship between the instrumental mass fractionation factors and elemental masses will improve isobaric interference corrections, particularly when chemical purification is imperfect or during laser ablation analysis.
引用
收藏
页码:4820 / 4828
页数:9
相关论文
共 50 条
  • [21] An optimal method for magnesium purification and magnesium isotopic composition obtained by MC-ICP-MS
    Liu, Jinke
    Han, Guilin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (09) : 1986 - 1995
  • [22] Plutonium and uranium isotope ratio measurement by MC-ICP-MS
    Taylor, RN
    Warneke, T
    Croudace, IW
    Milton, JA
    Warwick, PE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A766 - A766
  • [23] Quantitative Separation of Molybdenum and Rhenium from Geological Materials for Isotopic Determination by MC-ICP-MS
    Pearce, Christopher R.
    Cohen, Anthony S.
    Parkinson, Ian J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 219 - 229
  • [24] Accurate Measurement of Chromium Isotopic Compositions in Geological Reference Materials by Double-Spike MC-ICP-MS
    Shi, Kai
    Wu, Guangliang
    Zhu, Jian-Ming
    Wang, Xiangli
    ATOMIC SPECTROSCOPY, 2021, 42 (03) : 128 - 133
  • [25] Precise determination of U isotopic compositions in low concentration carbonate samples by MC-ICP-MS
    Wang, Ruo-Mei
    You, Chen-Feng
    TALANTA, 2013, 107 : 67 - 73
  • [26] In Situ Ti Isotopic Measurements by Laser Ablation MC-ICP-MS
    Chen, Hsin-Wei
    Lee, Typhoon
    Lee, Der-Chuen
    Iizuka, Yoshiyuki
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2009, 20 (05): : 703 - 712
  • [27] High-precision MC-ICP-MS measurements of Cd isotopes using a novel double spike method without Sn isobaric interference
    Li, Jin
    Tang, Suo-han
    Zhu, Xiangkun
    Ma, Jian-xiong
    Zhu, Zhiyong
    Yan, Bin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (12) : 3106 - 3115
  • [28] High-Precision Sn Isotopic Measurement in Geological Materials by Double-Spike MC-ICP-MS
    Song, Wenrui
    Zhu, Chuanwei
    Wen, Hanjie
    Zhang, Yuxu
    Liu, Zerui
    Zhou, Meifu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024,
  • [29] Measurements of lithium isotopic compositions in coal using MC-ICP-MS
    He, Mao-Yong
    Luo, Chong-guang
    Lu, Hai
    Jin, Zhang Dong
    Deng, Li
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (09) : 1773 - 1778
  • [30] Stable Cr isotope ratio measurements using a double-spike method and high-resolution MC-ICP-MS
    von Blanckenburg, F