Carbon nanotube/polysulfone screen-printed electrochemical immunosensor

被引:65
|
作者
Sanchez, Samuel
Pumera, Martin [1 ]
Fabregas, Esteve
机构
[1] Autonomous Univ Barcelona, Dept Chem, GSB, Bellaterra, Spain
[2] Natl Inst Mat Sci, ICYS, Tsukuba, Ibaraki, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 23卷 / 03期
关键词
polysulfone; immunosensor; amperometric biosensor; carbon nanotubes; composite; biocomposite; screen-printed electrode;
D O I
10.1016/j.bios.2007.04.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The simple and efficient method for preparing sensitive carbon nanotube/polysulfone/RIgG immunocomposite is described. The membrane of the modified disposable screen-printed electrochemical immunosensor is based on phase inversion method. Carbon nanotube/polysulfone membrane acts both as reservoir of immunological material and transducer while offering high surface area, high toughness and mechanical flexibility. The comparison with graphite/polysulfone/RIgG immunosensors shows a much higher sensitivity for those prepared with carbon nanotubes coupled with polysulfone (PSf). The membrane was characterized by scanning electron microscopy/energy dispersive X-ray analysis (SEM/EDX), laser profilometer and by atomic force microscopy (AFM). The purity of the materials was evaluated by thermogravimetric analysis (TGA). The roughness value is doubled when MWCNTs are used instead of graphite into the PSf membranes and the incorporation of antibodies enhances the dispersion of the carbon with the polymeric membrane reducing the roughness in all cases. This biosensor was based on the competitive assay between free and labelled anti-RIgG for the available binding sites of immobilized rabbit IgG (RIgG). The RIgG was incorporated into the polysulfone membrane by a phase inversion method. Horse radish peroxidase (HRP) enzyme was used as label and hydroquinone as mediator. The detection limit for competitive assay was determined to be 1.66 mu g/ml. the linear range of anti-RIgG from 2 to 5 mu g/ml and the C-50 was found at 3.56 mu g/ml. The sensitivity is five times higher for MWCNT than for graphite electrodes, showing lower unspecific adsorption. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:332 / 340
页数:9
相关论文
共 50 条
  • [41] Impedimetric Screen-Printed Immunosensor for the Rapid Detection of Chagas Disease
    Chain, Cecilia Y.
    Franchin, Lara
    Cisneros, Jose S.
    Villagra, Andrea P. M.
    Labriola, Carlos A.
    Paccagnella, Alessandro
    Bonaldo, Stefano
    IEEE SENSORS JOURNAL, 2024, 24 (02) : 1167 - 1174
  • [42] Field emission characteristics of screen-printed carbon nanotube after laser irradiation
    Zhao, WJ
    Sawada, A
    Takai, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2002, 41 (6B): : 4314 - 4316
  • [43] Immunosensor for the determination of okadaic acid based on screen-printed electrode
    Tang, A
    Kreuzer, M
    Lehane, M
    Pravda, M
    Guilbault, GG
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2003, 83 (7-8) : 663 - 670
  • [44] Selective plasma etching treatment of the screen-printed carbon nanotube cold cathode
    Yu, Jun
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2013, 62 (02):
  • [45] Field emission characteristics of screen-printed carbon nanotube after laser irradiation
    Zhao, Wei-Jiang
    Sawada, Akihiro
    Takai, Mikio
    1600, Japan Society of Applied Physics (41):
  • [46] Design and development of an amperometric immunosensor based on screen-printed electrodes
    Mistry, Kalyan Kumar
    Layek, Keya
    Chell, Tarak Nath
    Chaudhuri, Chirasree Roy
    Saha, Hiranmay
    ANALYTICAL METHODS, 2016, 8 (15) : 3096 - 3101
  • [47] Porous screen-printed carbon electrode
    Niu, Xiangheng
    Chen, Chen
    Zhao, Hongli
    Tang, Jie
    Li, Yuxiu
    Lan, Minbo
    ELECTROCHEMISTRY COMMUNICATIONS, 2012, 22 : 170 - 173
  • [48] An Amperometric Immunosensor for Microcystin-(Leucine-Arginine) Based on Screen-Printed Carbon Electrode
    Chen Xiang-Qiang
    He Miao
    Shi Han-Chang
    Cai Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (04) : 443 - 448
  • [49] Development of an immunosensor for the determination of rabbit IgG using streptavidin modified screen-printed carbon electrodes
    Díaz-González, M
    Hernández-Santos, D
    González-García, MB
    Costa-García, A
    TALANTA, 2005, 65 (02) : 565 - 573
  • [50] Facile Screen-Printed Carbon Nanotube Electrode on Porous Substrate with Gold Nanoparticle Modification for Rapid Electrochemical Gas Sensing
    Wan, Hao
    Liu, Xin
    Wang, Xinyi
    Chen, Yuantao
    Wang, Ping
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (06)