Carbon nanotube/polysulfone screen-printed electrochemical immunosensor

被引:65
|
作者
Sanchez, Samuel
Pumera, Martin [1 ]
Fabregas, Esteve
机构
[1] Autonomous Univ Barcelona, Dept Chem, GSB, Bellaterra, Spain
[2] Natl Inst Mat Sci, ICYS, Tsukuba, Ibaraki, Japan
来源
BIOSENSORS & BIOELECTRONICS | 2007年 / 23卷 / 03期
关键词
polysulfone; immunosensor; amperometric biosensor; carbon nanotubes; composite; biocomposite; screen-printed electrode;
D O I
10.1016/j.bios.2007.04.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The simple and efficient method for preparing sensitive carbon nanotube/polysulfone/RIgG immunocomposite is described. The membrane of the modified disposable screen-printed electrochemical immunosensor is based on phase inversion method. Carbon nanotube/polysulfone membrane acts both as reservoir of immunological material and transducer while offering high surface area, high toughness and mechanical flexibility. The comparison with graphite/polysulfone/RIgG immunosensors shows a much higher sensitivity for those prepared with carbon nanotubes coupled with polysulfone (PSf). The membrane was characterized by scanning electron microscopy/energy dispersive X-ray analysis (SEM/EDX), laser profilometer and by atomic force microscopy (AFM). The purity of the materials was evaluated by thermogravimetric analysis (TGA). The roughness value is doubled when MWCNTs are used instead of graphite into the PSf membranes and the incorporation of antibodies enhances the dispersion of the carbon with the polymeric membrane reducing the roughness in all cases. This biosensor was based on the competitive assay between free and labelled anti-RIgG for the available binding sites of immobilized rabbit IgG (RIgG). The RIgG was incorporated into the polysulfone membrane by a phase inversion method. Horse radish peroxidase (HRP) enzyme was used as label and hydroquinone as mediator. The detection limit for competitive assay was determined to be 1.66 mu g/ml. the linear range of anti-RIgG from 2 to 5 mu g/ml and the C-50 was found at 3.56 mu g/ml. The sensitivity is five times higher for MWCNT than for graphite electrodes, showing lower unspecific adsorption. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:332 / 340
页数:9
相关论文
共 50 条
  • [21] Screen-printed carbon electrode for the electrochemical detection of conjugated bilirubin
    Resmi, P. E.
    Raveendran, Jeethu
    Suneesh, P. V.
    Ramanchandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    MATERIALS LETTERS, 2021, 304
  • [22] Facile Fabrication of Screen-Printed Carbon Electrodes for Electrochemical Sensors
    Sarmphim, P.
    Teeparuksapun, K.
    Wunsri, S.
    Sorngodchagorn, S.
    Duangsiri, W.
    Tapparak, P.
    Sirisathitkul, C.
    INTERNATIONAL JOURNAL OF NANOELECTRONICS AND MATERIALS, 2021, 14 (01): : 1 - 10
  • [23] Electrochemical Characterization of Ordered Mesoporous Carbon Screen-Printed Electrodes
    Martin-Yerga, Daniel
    Costa Rama, Estefania
    Costa-Garcia, Agustin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (05) : B176 - B179
  • [24] Electrochemical Behavior of Screen-Printed Carbon Electrodes as Transducers in Biosensors
    Dorledo de Faria, Ricardo Adriano
    Douaud, Alexandre
    Soares, Renata Braga
    Dias Heneine, Luiz Guilherme
    Matencio, Tulio
    Cunha Lins, Vanessa de Freitas
    Messaddeq, Younes
    CORROSION, 2020, 76 (06) : 553 - 561
  • [25] Electrochemical characterization of screen-printed and conventional carbon paste electrodes
    Fanjul-Bolado, Pablo
    Hernandez-Santos, David
    Lamas-Ardisana, Pedro Jos
    Martin-Pernia, Alberto
    Costa-Garcia, Agustin
    ELECTROCHIMICA ACTA, 2008, 53 (10) : 3635 - 3642
  • [26] Research on intense pulsed emission of screen-printed carbon nanotube cathode
    Liao, Qing-Liang
    Zhang, Yue
    Xia, Lian-Sheng
    Qi, Jun-Jie
    Huang, Yun-Hua
    Deng, Zhan-Qiang
    Gao, Zhan-Jun
    Cao, Jia-Wei
    Wuli Xuebao/Acta Physica Sinica, 2008, 57 (04): : 2328 - 2333
  • [27] Research on intense pulsed emission of screen-printed carbon nanotube cathode
    Liao Qing-Liang
    Zhang Yue
    Xia Lian-Sheng
    Qi Jun-Jie
    Huang Yun-Hua
    Deng Zhan-Qiang
    Gao Zhan-Jun
    Cao Jia-Wei
    ACTA PHYSICA SINICA, 2008, 57 (04) : 2328 - 2333
  • [28] Sensitive Electrochemical Immunosensor for Detection of Mycotoxins Aflatoxin B1 Using Disposable screen-Printed Carbon Electrode
    Liu, Ping
    Qi, Xingpu
    Zhang, Huanxin
    Zheng, Yi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (03): : 1 - 11
  • [29] Development of an electrochemical immunosensor for specific detection of visceral leishmaniasis using gold-modified screen-printed carbon electrodes
    Martins B.R.
    Barbosa Y.O.
    Andrade C.M.R.
    Pereira L.Q.
    Simão G.F.
    de Oliveira C.J.
    Correia D.
    Oliveira R.T.S.
    da Silva M.V.
    Silva A.C.A.
    Dantas N.O.
    Rodrigues V.
    Muñoz R.A.A.
    Alves-Balvedi R.P.
    Biosensors, 2020, 10 (08):
  • [30] Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins:: A sensor for aflatoxin B1
    Pemberton, R. M.
    Pittson, R.
    Biddle, N.
    Drago, G. A.
    Hart, J. P.