Deformable Registration of the Inflated and Deflated Lung for Cone-Beam CT-Guided Thoracic Surgery

被引:1
|
作者
Uneri, Ali [1 ]
Nithiananthan, Sajendra [2 ]
Schafer, Sebastian [2 ]
Otake, Yoshito [1 ,2 ]
Stayman, J. Webster [2 ]
Kleinszig, Gerhard [3 ]
Sussman, Marc S. [4 ]
Taylor, Russell H. [1 ]
Prince, Jerry L. [5 ]
Siewerdsen, Jeffrey H. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21218 USA
[3] Siemens Healthcare, Erlangen, Germany
[4] Johns Hopkins Bayview Med Ctr, Dept Surg, Baltimore, MD 21218 USA
[5] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
基金
美国国家卫生研究院;
关键词
CANCER; LOCALIZATION;
D O I
10.1117/12.911440
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Intraoperative cone-beam CT (CBCT) could offer an important advance to thoracic surgeons in directly localizing subpalpable nodules during surgery. An image-guidance system is under development using mobile C-arm CBCT to directly localize tumors in the OR, potentially reducing the cost and logistical burden of conventional preoperative localization and facilitating safer surgery by visualizing critical structures surrounding the surgical target (e. g., pulmonary artery, airways, etc.). To utilize the wealth of preoperative image/planning data and to guide targeting under conditions in which the tumor may not be directly visualized, a deformable registration approach has been developed that geometrically resolves images of the inflated (i.e., inhale or exhale) and deflated states of the lung. This novel technique employs a coarse model-driven approach using lung surface and bronchial airways for fast registration, followed by an image-driven registration using a variant of the Demons algorithm to improve target localization to within similar to 1 mm. Two approaches to model-driven registration are presented and compared - the first involving point correspondences on the surface of the deflated and inflated lung and the second a mesh evolution approach. Intensity variations (i.e., higher image intensity in the deflated lung) due to expulsion of air from the lungs are accounted for using an a priori lung density modification, and its improvement on the performance of the intensity-driven Demons algorithm is demonstrated. Preliminary results of the combined model-driven and intensity-driven registration process demonstrate accuracy consistent with requirements in minimally invasive thoracic surgery in both target localization and critical structure avoidance.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Empiric cone-beam CT-guided embolization in acute lower gastrointestinal bleeding
    Laurens Hermie
    Elisabeth Dhondt
    Peter Vanlangenhove
    Jan De Waele
    Helena Degroote
    Luc Defreyne
    European Radiology, 2021, 31 : 2161 - 2172
  • [42] Empiric cone-beam CT-guided embolization in acute lower gastrointestinal bleeding
    Hermie, Laurens
    Dhondt, Elisabeth
    Vanlangenhove, Peter
    De Waele, Jan
    Degroote, Helena
    Defreyne, Luc
    EUROPEAN RADIOLOGY, 2021, 31 (04) : 2161 - 2172
  • [43] Feasibility and reproducibility of cone-beam CT guided lung radiotherapy using registration to bone, carina, and tumor
    Higgins, J.
    Bezjak, A.
    Franks, K.
    Payne, D.
    Chol, J.
    Le, L.
    Bissonnette, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S520 - S520
  • [44] Deformable Registration of MRI to Intraoperative Cone-Beam CT of the Brain Using a Joint Synthesis and Registration Network
    Han, R.
    Jones, C. K.
    Wu, P.
    Vagdargi, P.
    Zhang, X.
    Uneri, A.
    Lee, J.
    Luciano, M.
    Anderson, W. S.
    Helm, P.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [45] Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions
    Hamming, N. M.
    Daly, M. J.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2009, 36 (05) : 1800 - 1812
  • [46] Calibration correction to improve registration during cone-beam CT guided histotripsy
    Falk, Katrina L.
    Laeseke, Paul F.
    Minesinger, Grace M.
    Ozkan, Orhan G.
    Speidel, Michael A.
    Ziemlewicz, Timothy J.
    Lee Jr, Fred T.
    Wagner, Martin G.
    MEDICAL PHYSICS, 2025,
  • [47] A more effective CT synthesizer using transformers for cone-beam CT-guided adaptive radiotherapy
    Chen, Xinyuan
    Liu, Yuxiang
    Yang, Bining
    Zhu, Ji
    Yuan, Siqi
    Xie, Xuejie
    Liu, Yueping
    Dai, Jianrong
    Men, Kuo
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [48] An electromagnetic "Tracker-in-Table" configuration for X-ray fluoroscopy and cone-beam CT-guided surgery
    Yoo, J.
    Schafer, S.
    Uneri, A.
    Otake, Y.
    Khanna, A. J.
    Siewerdsen, J. H.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (01) : 1 - 13
  • [49] Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications
    Hong, Wonju
    Yoon, Soon Ho
    Goo, Jin Mo
    Park, Chang Min
    KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (07) : 1203 - 1212
  • [50] Immediate and Follow-up Imaging Findings after Cone-Beam CT-guided Transbronchial Lung Cryobiopsy
    Pogatchnik, Brian P.
    Swenson, Kai E.
    Duong, Duy Kevin
    Shaller, Brian
    Bedi, Harmeet
    Guo, H. Henry
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2023, 5 (02):