摘要
Intraoperative cone-beam CT (CBCT) could offer an important advance to thoracic surgeons in directly localizing subpalpable nodules during surgery. An image-guidance system is under development using mobile C-arm CBCT to directly localize tumors in the OR, potentially reducing the cost and logistical burden of conventional preoperative localization and facilitating safer surgery by visualizing critical structures surrounding the surgical target (e. g., pulmonary artery, airways, etc.). To utilize the wealth of preoperative image/planning data and to guide targeting under conditions in which the tumor may not be directly visualized, a deformable registration approach has been developed that geometrically resolves images of the inflated (i.e., inhale or exhale) and deflated states of the lung. This novel technique employs a coarse model-driven approach using lung surface and bronchial airways for fast registration, followed by an image-driven registration using a variant of the Demons algorithm to improve target localization to within similar to 1 mm. Two approaches to model-driven registration are presented and compared - the first involving point correspondences on the surface of the deflated and inflated lung and the second a mesh evolution approach. Intensity variations (i.e., higher image intensity in the deflated lung) due to expulsion of air from the lungs are accounted for using an a priori lung density modification, and its improvement on the performance of the intensity-driven Demons algorithm is demonstrated. Preliminary results of the combined model-driven and intensity-driven registration process demonstrate accuracy consistent with requirements in minimally invasive thoracic surgery in both target localization and critical structure avoidance.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [32] Unsupervised learning for deformable registration of thoracic CT and cone-beam CT based on multiscale features matching with spatially adaptive weighting
    Duan, Luwen
    Ni, Xinye
    Liu, Qi
    Gong, Lun
    Yuan, Gang
    Li, Ming
    Yang, Xiaodong
    Fu, Tianxiao
    Zheng, Jian
    MEDICAL PHYSICS, 2020, 47 (11) : 5632 - 5647
  • [33] Deformable image registration for cone-beam CT (CBCT) images for implemantion of image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Ahamad, A.
    Zhu, X. R.
    Garden, A. S.
    Ang, K. K.
    Mohan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S647 - S648
  • [34] Converting Cone-Beam CT to In-Room Conventional CT by a Deformable Image Registration Method
    Zhang, Y.
    Yang, J.
    Zhang, L.
    Dong, L.
    MEDICAL PHYSICS, 2009, 36 (06) : 2477 - +
  • [35] Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Uneri, Ali
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Brock, Kristy K.
    Daly, Michael J.
    Chan, Harley
    Irish, Jonathan C.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2011, 38 (04) : 1785 - 1798
  • [36] Deformable planning CT to cone-beam CT image registration in head-and-neck cancer
    Hou, Jidong
    Guerrero, Mariana
    Chen, Wenjuan
    D'Souza, Warren D.
    MEDICAL PHYSICS, 2011, 38 (04) : 2088 - 2094
  • [37] STEREOTACTIC TREATMENT OF lUNG MALIGNANCIES GUIDED BY CONE-BEAM CT
    Casamassima, F.
    Masi, L.
    Polli, C.
    Bonucci, I.
    Menichelli, C.
    D'Imporzano, E.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S291 - S291
  • [38] A Hybrid Deformable Registration Method between Helical CT and Cone-Beam CT for Prostate Patient
    Qin, A.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [39] Tracker-on-C for Cone-Beam CT-Guided Surgery: Evaluation of Geometric Accuracy and Clinical Applications
    Reaungamornrat, S.
    Otake, Y.
    Uneri, A.
    Schafer, S.
    Mirota, D. J.
    Nithiananthan, S.
    Stayman, J. W.
    Khanna, A. J.
    Reh, D. D.
    Gallia, G. L.
    Taylor, R. H.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [40] A target containing phantom for accuracy assessment of cone-beam CT-guided histotripsy
    Kutlu, Ayca Z.
    Minesinger, Grace M.
    Laeseke, Paul F.
    Speidel, Michael
    Wagner, Martin G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (05):