Integrated multi-objective membrane systems for surface water treatment: pretreatment of reverse osmosis by conventional treatment and ultrafiltration

被引:31
|
作者
Kruithof, JC
Schippers, JC
Kamp, PC
Folmer, HC
Hofman, JAMH
机构
[1] Kiwa NV Res & Consultancy, NL-3430 BB Nieuwegein, Netherlands
[2] NV PWN Water Supply Co N Holland, NL-2060 BA Bloemendaal, Netherlands
[3] Amsterdam Water Supply, NL-1005 AD Amsterdam, Netherlands
关键词
integrated multi-objective membrane systems; pretreatment; reverse osmosis; ultrafiltration;
D O I
10.1016/S0011-9164(98)00065-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Within the scope of this project funded by AWWARF and USEPA three very promising IMS's were identified for surface water treatment. This paper will cover some highlights of the research carried out by the Water Supply Company of North Holland and Kiwa on the combination ultrafiltration/ultra low pressure reverse osmosis. Productivity of the ultrafiltration proved to be stable for the first 6000 h. Then, at the end of summer, the backwash regime was not able to prevent accumulation of biofouling. This biofouling coincides with an increase in bacterial counts in the ultrafiltrate. Also the ultra low pressure reverse osmosis unit showed no significant fouling up to 6000 hours. Then a rapid decrease of the second stage MTC started caused by BaSO4 precipitation, coinciding with an increase in feed-concentrate pressure drop caused by a severe biofouling. Ultrafiltration reduced the indicator organisms E. coli and spores of sulphite reducing Clostridia to under the detection limit. To determine the elimination capacity the feed of UF and ULPRO were spiked with MS-2 phages. Generally UF showed a complete (>5 log) removal. Once only a 2.7 log removal was found caused by defects in UF-membranes. ULPRO showed a high (4.7-4.9 log) although no complete removal. The results show that integrity measurement and monitoring of both membrane steps are essential. UF-integrity is measured by a pressure hold test and monitored by particle counting. integrity of ULPRO is measured by vacuum testing and monitored by in situ conductivity measurement and particle counting. ULPRO gives a very high precursor removal. Potential measurements (24 h, 20 degrees C, 1-2 mg/l Cl-2-residual) showed >95% removal of THMFP and HAAFP. IMS with UF and ULPRO are exceptional tools for control of microbials and DBP-precursors. Crucial for application may be control of biofouling in the system.
引用
收藏
页码:37 / 48
页数:12
相关论文
共 50 条
  • [41] Pretreatment for membrane water treatment systems: a laboratory study
    Wend, CF
    Stewart, PS
    Jones, W
    Camper, AK
    WATER RESEARCH, 2003, 37 (14) : 3367 - 3378
  • [42] Comparison of post-process coke wastewater treatment effectiveness in integrated and hybrid systems that combine coagulation, ultrafiltration, and reverse osmosis
    Mielczarek, Karolina
    Bohdziewicz, Jolanta
    Wlodarczyk-Makula, Maria
    Smol, Marzena
    DESALINATION AND WATER TREATMENT, 2014, 52 (19-21) : 3879 - 3888
  • [43] Optimal design of reverse osmosis-based water treatment systems
    Karuppiah, Ramkumar
    Bury, Scott J.
    Vazquez, Adriana
    Poppe, Gregg
    AICHE JOURNAL, 2012, 58 (09) : 2758 - 2769
  • [44] Investigation of membrane fouling in surface treatment plant using reverse osmosis process
    Mohammed, H. Zerrouk
    Jalal, Isaad
    Gutierres Gomes, Santiago
    Tarik, Chafi
    Quiroga Alonso, Jose Maria
    MOROCCAN JOURNAL OF CHEMISTRY, 2016, 4 (02): : 308 - 314
  • [45] Membrane distillation for wastewater reverse osmosis concentrate treatment with water reuse potential
    Naidu, Gayathri
    Jeong, Sanghyun
    Choi, Youngkwon
    Vigneswaran, Saravanamuthu
    JOURNAL OF MEMBRANE SCIENCE, 2017, 524 : 565 - 575
  • [46] Comparison of methods for assessing reverse osmosis membrane treatment of shrimp process water
    Casani, S
    Hansen, TB
    Christensen, J
    Knochel, S
    JOURNAL OF FOOD PROTECTION, 2005, 68 (04) : 801 - 807
  • [47] Impact of polyacrylamide residue on reverse osmosis membrane fouling in mine water treatment
    Guo Z.
    Mao W.
    Xiao Y.
    Zheng P.
    Ma S.
    Meitan Xuebao/Journal of the China Coal Society, 2020, 45 : 986 - 992
  • [48] Development and experience with new FILMTEC reverse osmosis membrane elements for water treatment
    Redondo, JA
    DESALINATION, 1997, 108 (1-3) : 59 - 66
  • [49] Effect of conventional chemical treatment on the microbial population in a biofouling layer of reverse osmosis systems
    Bereschenko, L. A.
    Prummel, H.
    Euverink, G. J. W.
    Stams, A. J. M.
    van Loosdrech, M. C. M.
    WATER RESEARCH, 2011, 45 (02) : 405 - 416
  • [50] Effect of Electric Field on Membrane Fouling and Membrane Performance in Reverse Osmosis Treatment of Brackish Water
    Fu, Caixia
    Yi, Xuenong
    Gao, Yuqiong
    APPLIED SCIENCES-BASEL, 2024, 14 (02):