Integrated multi-objective membrane systems for surface water treatment: pretreatment of reverse osmosis by conventional treatment and ultrafiltration

被引:31
|
作者
Kruithof, JC
Schippers, JC
Kamp, PC
Folmer, HC
Hofman, JAMH
机构
[1] Kiwa NV Res & Consultancy, NL-3430 BB Nieuwegein, Netherlands
[2] NV PWN Water Supply Co N Holland, NL-2060 BA Bloemendaal, Netherlands
[3] Amsterdam Water Supply, NL-1005 AD Amsterdam, Netherlands
关键词
integrated multi-objective membrane systems; pretreatment; reverse osmosis; ultrafiltration;
D O I
10.1016/S0011-9164(98)00065-4
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Within the scope of this project funded by AWWARF and USEPA three very promising IMS's were identified for surface water treatment. This paper will cover some highlights of the research carried out by the Water Supply Company of North Holland and Kiwa on the combination ultrafiltration/ultra low pressure reverse osmosis. Productivity of the ultrafiltration proved to be stable for the first 6000 h. Then, at the end of summer, the backwash regime was not able to prevent accumulation of biofouling. This biofouling coincides with an increase in bacterial counts in the ultrafiltrate. Also the ultra low pressure reverse osmosis unit showed no significant fouling up to 6000 hours. Then a rapid decrease of the second stage MTC started caused by BaSO4 precipitation, coinciding with an increase in feed-concentrate pressure drop caused by a severe biofouling. Ultrafiltration reduced the indicator organisms E. coli and spores of sulphite reducing Clostridia to under the detection limit. To determine the elimination capacity the feed of UF and ULPRO were spiked with MS-2 phages. Generally UF showed a complete (>5 log) removal. Once only a 2.7 log removal was found caused by defects in UF-membranes. ULPRO showed a high (4.7-4.9 log) although no complete removal. The results show that integrity measurement and monitoring of both membrane steps are essential. UF-integrity is measured by a pressure hold test and monitored by particle counting. integrity of ULPRO is measured by vacuum testing and monitored by in situ conductivity measurement and particle counting. ULPRO gives a very high precursor removal. Potential measurements (24 h, 20 degrees C, 1-2 mg/l Cl-2-residual) showed >95% removal of THMFP and HAAFP. IMS with UF and ULPRO are exceptional tools for control of microbials and DBP-precursors. Crucial for application may be control of biofouling in the system.
引用
收藏
页码:37 / 48
页数:12
相关论文
共 50 条
  • [21] Sustainable Reverse Osmosis Desalination Systems: Comprehensive Superstructure Modeling and Multi-Objective Optimization
    Nour-Mohammad, Mohammad
    Fakhroleslam, Mohammad
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2025,
  • [22] Ultrafiltration and reverse osmosis integrated to conventional drinking water treatment to ensure human right to water in dam break scenarios: From bench- to pilot-scale
    Moreira, Victor R.
    Moser, Priscila B.
    Guimaraes, Roberta N.
    Amaral, Miriam C. S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2025, 353
  • [23] Filtration demonstration plant as reverse osmosis pretreatment in an industrial water treatment plant
    Quevedo, Noelia
    Sanz, Joan
    Lobo, Amaya
    Temprano, Javier
    Tejero, Inaki
    DESALINATION, 2012, 286 : 49 - 55
  • [24] Membrane distillation and novel integrated membrane process for reverse osmosis drained wastewater treatment
    Wu Chunrui
    Jia Yue
    Chen Huayan
    Wang Xuan
    Lu Xiaolong
    DESALINATION AND WATER TREATMENT, 2010, 18 (1-3) : 286 - 291
  • [25] Treatment of reverse osmosis brine by direct contact membrane distillation: Chemical pretreatment approach
    Sanmartino, J. A.
    Khayet, M.
    Garcia-Payo, M. C.
    El-Balcouri, H.
    Riaza, A.
    DESALINATION, 2017, 420 : 79 - 90
  • [26] Treatment of chemical mechanical polishing wastewater for water reuse by ultrafiltration and reverse osmosis separation
    Juang, Lain-Chuen
    Tseng, Dyi-Hwa
    Lin, He-Yin
    Lee, Chung-Kung
    Liang, Teh-Ming
    ENVIRONMENTAL ENGINEERING SCIENCE, 2008, 25 (07) : 1091 - 1098
  • [27] Membrane bioreactor/reverse osmosis system for gray water treatment and reuse
    Griggs, Christopher
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 258
  • [28] Application of Ceramic Filter and Reverse Osmosis Membrane for Produced Water Treatment
    Putri, Rara Eka Dyla
    Nasir, Subriyer
    Hadiah, Fitri
    POLLUTION, 2022, 8 (04): : 1103 - 1115
  • [29] Water treatment using membrane bioreactor-reverse osmosis technology
    不详
    FOOD AUSTRALIA, 2011, 63 (07): : 270 - 271
  • [30] Comparison between reverse osmosis and membrane distillation for bilge water treatment
    Bottino, A.
    Comite, A.
    Ferrari, F.
    Jezowska, A.
    Voena, A.
    Capannelli, G.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1700 - 1702