Electrochemical Performance of Screen Printed Sensors for Potentiometric Determination of Anticholinergic Oxybutynine Hydrochloride in Pharmaceutical Formulations and Biological Fluids

被引:2
|
作者
Mostafa, Maysa R. [1 ]
Mohamed, Gehad G. [1 ,2 ]
Ali, Tamer A. [3 ]
Frag, Eman Y. Z. [1 ]
Mohamed, Marwa E. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
[2] Cairo Univ, Egypt Nanotechnol Ctr, Giza 12588, Egypt
[3] EPRI, Analyt Chem Dept, Cairo, Egypt
来源
EGYPTIAN JOURNAL OF CHEMISTRY | 2020年 / 63卷 / 05期
关键词
MSPE; Ion pairing agents; Oxybutynine HCl; Pharmaceutical formulation; Biological fluids; ANTIHISTAMINIC DIPHENHYDRAMINE HYDROCHLORIDE; CONSTRUCTION; ELECTRODES; PURE;
D O I
10.21608/ejchem.2019.17956.2097
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
NEW potentiometric sensitive and selective modified screen printed electrodes (MSPE) which based on phosphotungestic acid (PTA), sodium tetraphenyl borate (NaTPB), phosphomolybdic acid (PMA) or ammonium reineckate (RN) ion pairing agents for determination of oxybutynine hydrochloride (OBCH) were developed. The proposed electrodes have Nernstian slope values of 59.200.52 +/-, 58.000.22 +/- and 58.520.22 +/- mV decade(-1) for electrodes modified with 7.5, 17.5 and 7.5 mg of RN (electrode I), NaTPB (electrode II) and PTA (electrode III) ion pairing agents, respectively. It is found that the dynamic drug concentration range at 25 degrees C was 1.0x10(-5) -1.0x10(-2) mole L-1 with detection limit (LOD) equal 1.0x 10(-5) mol L-1 and limit of quantification (LOQ) equal 3.33x10(-5) mol L-1. The response of MSPEs was pH independent in the range 2.0-6.0. The investigated electrodes have fast response time of 10, 9 and 8 s for electrodes I, II and III, respectively. These electrodes have good Nernstian response in the temperature range 10-60 degrees C. The slope of the straight-line obtained represented the isothermal coefficient of MSPEs which were found to be 1.594 x10(-3), 2.151x10(-3) and 2.377x10(-3) V/ for electrodes I, II and III, respectively. The small values of the isothermal coefficient indicated the high thermal stability of the electrodes. The MSPEs showed a relatively long life time of 36 days. Pure, biological fluids and pharmaceutical formulation of OBCH were quantified using calibration and standard addition methods and the obtained results agreed with that of the official HPLC method. Validation parameters were optimized according to ICH recommendations.
引用
收藏
页码:1799 / 1809
页数:11
相关论文
共 50 条
  • [41] Potentiometric Determination of Mepivacaine Hydrochloride Local Anesthetic Drug in Pharmaceutical and Biological Fluids Using Ion Selective Electrode
    Ali, Tamer Awad
    Mohamed, Gehad G.
    Abd El-Hamid, N. S.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (07): : 3323 - 3334
  • [42] Spectrofluorimetric determination of prenalterol hydrochloride in pharmaceutical preparations and biological fluids
    Aly, FA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 18 (06) : 993 - 997
  • [43] Erratum to: Disposable screen-printed sensors for determination of Duloxetine Hydrochloride
    Nawal A Alarfaj
    Reda A Ammar
    Maha F El-Tohamy
    Chemistry Central Journal, 6
  • [44] Polyvinyl Chloride Membrane Sensors for Potentiometric Determination of Chlorpromazine in Some Pharmaceutical Formulations
    Abounassif, M. A.
    Hefnawy, M. M.
    Hassanien, M. M.
    Mostafa, Gamal A. E.
    SENSOR LETTERS, 2012, 10 (3-4) : 966 - 973
  • [45] PVC matrix membrane sensor for potentiometric determination of metoclopramide hydrochloride in some pharmaceutical formulations
    Mostafa, GAE
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (03) : 515 - 521
  • [46] Electrochemical Determination of Hydralazine Hydrochloride by Preanodised Screen Printed Carbon Electrode
    Cheemalapati, Srikanth
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 11488 - 11496
  • [47] New potentiometric screen-printed sensors for determination of homologous sodium alkylsulfates
    Makarova, N. M.
    Kulapina, E. G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 817 - 824
  • [48] β- Cyclodextrin / Carbon Xerogel Based Potentiometric Screen Printed Sensor for Determination of Meclofenoxate Hydrochloride
    Aleem, A. A. Abdul
    Khaled, Elmorsy
    Farghali, Ahmed A.
    Abdelwahab, Abdalla
    Khalil, M. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (04): : 3365 - 3381
  • [49] A validated potentiometric method for determination of alfuzosin hydrochloride in pharmaceutical and biological fluid samples
    Mohamed, Marwa El Badry
    Frag, Eman Y.
    Eldin, Yasmin M. Gamal
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (09) : 2257 - 2265
  • [50] A validated potentiometric method for determination of alfuzosin hydrochloride in pharmaceutical and biological fluid samples
    Marwa El Badry Mohamed
    Eman Y. Frag
    Yasmin M. Gamal Eldin
    Journal of the Iranian Chemical Society, 2020, 17 : 2257 - 2265