Electrochemical Performance of Screen Printed Sensors for Potentiometric Determination of Anticholinergic Oxybutynine Hydrochloride in Pharmaceutical Formulations and Biological Fluids

被引:2
|
作者
Mostafa, Maysa R. [1 ]
Mohamed, Gehad G. [1 ,2 ]
Ali, Tamer A. [3 ]
Frag, Eman Y. Z. [1 ]
Mohamed, Marwa E. [1 ]
机构
[1] Cairo Univ, Fac Sci, Chem Dept, Giza 12613, Egypt
[2] Cairo Univ, Egypt Nanotechnol Ctr, Giza 12588, Egypt
[3] EPRI, Analyt Chem Dept, Cairo, Egypt
来源
EGYPTIAN JOURNAL OF CHEMISTRY | 2020年 / 63卷 / 05期
关键词
MSPE; Ion pairing agents; Oxybutynine HCl; Pharmaceutical formulation; Biological fluids; ANTIHISTAMINIC DIPHENHYDRAMINE HYDROCHLORIDE; CONSTRUCTION; ELECTRODES; PURE;
D O I
10.21608/ejchem.2019.17956.2097
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
NEW potentiometric sensitive and selective modified screen printed electrodes (MSPE) which based on phosphotungestic acid (PTA), sodium tetraphenyl borate (NaTPB), phosphomolybdic acid (PMA) or ammonium reineckate (RN) ion pairing agents for determination of oxybutynine hydrochloride (OBCH) were developed. The proposed electrodes have Nernstian slope values of 59.200.52 +/-, 58.000.22 +/- and 58.520.22 +/- mV decade(-1) for electrodes modified with 7.5, 17.5 and 7.5 mg of RN (electrode I), NaTPB (electrode II) and PTA (electrode III) ion pairing agents, respectively. It is found that the dynamic drug concentration range at 25 degrees C was 1.0x10(-5) -1.0x10(-2) mole L-1 with detection limit (LOD) equal 1.0x 10(-5) mol L-1 and limit of quantification (LOQ) equal 3.33x10(-5) mol L-1. The response of MSPEs was pH independent in the range 2.0-6.0. The investigated electrodes have fast response time of 10, 9 and 8 s for electrodes I, II and III, respectively. These electrodes have good Nernstian response in the temperature range 10-60 degrees C. The slope of the straight-line obtained represented the isothermal coefficient of MSPEs which were found to be 1.594 x10(-3), 2.151x10(-3) and 2.377x10(-3) V/ for electrodes I, II and III, respectively. The small values of the isothermal coefficient indicated the high thermal stability of the electrodes. The MSPEs showed a relatively long life time of 36 days. Pure, biological fluids and pharmaceutical formulation of OBCH were quantified using calibration and standard addition methods and the obtained results agreed with that of the official HPLC method. Validation parameters were optimized according to ICH recommendations.
引用
收藏
页码:1799 / 1809
页数:11
相关论文
共 50 条
  • [21] Construction and Performance Characterization of Ion-Selective Electrodes for Potentiometric Determination of Paroxetine Hydrochloride in Pharmaceutical Preparations and Biological Fluids
    Khalil, Mohamed M.
    Issa, Yousry M.
    Mohamed, Ali G.
    ELECTROANALYSIS, 2014, 26 (12) : 2789 - 2800
  • [22] Potentiometric Determination of Betahistine in Pharmaceutical Formulations by Drug Selective Sensors
    Ganjali, Mohammad Reza
    Aghili, Sarah
    Larijani, Bagher
    Ghasemi, Mohammad Hadi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1893 - 1903
  • [23] Highly Sensitive Potentiometric Assay of Vardenafil in Pharmaceutical Formulations and Biological Fluids
    Gad, Esmail M.
    Hendawy, Hassan A. M.
    Fouad, Marwa A.
    Khaled, Elmorsy
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (01): : 397 - 406
  • [24] Disposable screen printed potentiometric sensors for determination of free radicals
    Campanella, L
    Favero, G
    Marino, S
    Pilloton, R
    Tomassetti, M
    Sensors and Microsystems, 2002, : 358 - 362
  • [25] Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations
    Mostafa, G.A.E.
    2003, Maik Nauka (58):
  • [26] Potentiometric Membrane Sensors for the Selective Determination of Pyridoxine Hydrochloride (Vitamin B6) in Some Pharmaceutical Formulations
    G. A. E. Mostafa
    Journal of Analytical Chemistry, 2003, 58 : 1073 - 1077
  • [27] Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations
    Mostafa, GAH
    Ghazy, SE
    ANNALI DI CHIMICA, 2003, 93 (7-8) : 691 - 699
  • [28] Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations
    Mostafa, GAE
    JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 58 (11) : 1073 - 1077
  • [29] Disposable screen-printed sensors for determination of duloxetine hydrochloride
    Nawal A Alarfaj
    Reda A Ammar
    Maha F El-Tohamy
    Chemistry Central Journal, 6
  • [30] Potentiometric Membrane Sensors for the Selective Determination of Memantine Hydrochloride in Pharmaceutical Preparations
    El Nashar, Rasha M.
    El-Tantawy, Aliaa S. M.
    Hassan, Saad S. M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10802 - 10817