The calibration of dosimetry instruments used in interventional radiology

被引:0
|
作者
Rannikko, S [1 ]
机构
[1] Univ Helsinki, Inst Biomed, FIN-00014 Helsinki, Finland
来源
DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND) | 2001年
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
No general agreement about the definition of the patient dose exists. As regards the radiation health risk, the doses to specific organs. H-i, are the ultimate measures for a patient dose. Values of the calibration measurand, H-i, are provided only by calculational means. Out of the whole process of patient dose determination, the instruments to measure X ray spectra, FSD, field dimensions and K-a can be calibrated. X ray quality is derived from the total filtration and kV value. The actual dynamic and X ray quality ranges shall be considered when air kerma and DAP meters are calibrated. A DAP meter measurement averages the uniform radiation field specific for the X ray tube assembly used and for the beam shaping technique performed. Therefore, a DAP meter calibrated on site is preferable for patient dosimetry in interventional radiology.
引用
收藏
页码:151 / 153
页数:3
相关论文
共 50 条
  • [31] Understanding the Basics of Commonly Used Wires in Interventional Radiology
    Pandhi, Mithil B.
    Tyagi, Ravi
    Surabhi, Divya
    Shah, Ketan Y.
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2021, 38 (04) : 504 - 508
  • [32] Quality control of equipment used in digital and interventional radiology
    Zoetelief, J
    van Soldt, RTM
    Suliman, II
    Jansen, JTM
    Bosmans, H
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 277 - 282
  • [33] EYE DOSIMETRY IN INTERVENTIONAL RADIOLOGY AND CARDIOLOGY: CURRENT CHALLENGES AND PRACTICAL CONSIDERATIONS
    Ciraj-Bjelac, O.
    Rehani, M. M.
    RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 329 - 337
  • [34] Investigating the potential of polymer gel dosimetry for interventional radiology: first results
    Antoniou, P. E.
    Bousbouras, P.
    Sandaltzopoulos, R.
    Kaldoudi, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (08): : N127 - N136
  • [35] A practical method for routine eye lens dosimetry of staff in interventional radiology
    Bergans, Niki
    Vandermaesen, Alexander
    Vanheule, Jeroen
    Bogaerts, Ria
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (15-16) : 1779 - 1784
  • [36] Evaluation of the calibration procedure of active personal dosemeters for interventional radiology
    Bordy, J. -M.
    Daures, J.
    Clairand, I.
    Denoziere, M.
    Donadille, L.
    d'Errico, F.
    Gouriou, J.
    Itie, C.
    Struelens, L.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 87 - 92
  • [37] COMMENTS ON THE ACTIVE INSTRUMENTS USED IN THE AGS DOSIMETRY STUDY
    HANDLOSER, J
    HEALTH PHYSICS, 1994, 66 (01): : 96 - 96
  • [38] A SECONDARY STANDARD DOSIMETRY SYSTEM FOR CALIBRATION OF RADIATION PROTECTION INSTRUMENTS
    DUFTSCHMID, KE
    HIZO, J
    ACTA PHYSICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1982, 52 (3-4): : 275 - 282
  • [39] Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
    Bordy, J. M.
    Daures, J.
    Denoziere, M.
    Gualdrini, G.
    Ginjaume, M.
    Carinou, E.
    Vanhavere, F.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1235 - 1238
  • [40] The Interventional Radiology/Diagnostic Radiology Certificate and Interventional Radiology Residency
    Kaufman, John A.
    RADIOLOGY, 2014, 273 (02) : 318 - 321