The calibration of dosimetry instruments used in interventional radiology

被引:0
|
作者
Rannikko, S [1 ]
机构
[1] Univ Helsinki, Inst Biomed, FIN-00014 Helsinki, Finland
来源
DOSE AND IMAGE QUALITY IN DIGITAL IMAGING AND INTERVENTIONAL RADIOLOGY (DIMOND) | 2001年
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
No general agreement about the definition of the patient dose exists. As regards the radiation health risk, the doses to specific organs. H-i, are the ultimate measures for a patient dose. Values of the calibration measurand, H-i, are provided only by calculational means. Out of the whole process of patient dose determination, the instruments to measure X ray spectra, FSD, field dimensions and K-a can be calibrated. X ray quality is derived from the total filtration and kV value. The actual dynamic and X ray quality ranges shall be considered when air kerma and DAP meters are calibrated. A DAP meter measurement averages the uniform radiation field specific for the X ray tube assembly used and for the beam shaping technique performed. Therefore, a DAP meter calibrated on site is preferable for patient dosimetry in interventional radiology.
引用
收藏
页码:151 / 153
页数:3
相关论文
共 50 条
  • [21] Fast Monte Carlo codes for occupational dosimetry in interventional radiology
    Garcia Balcaza, V
    Camp, A.
    Badal, A.
    Andersson, M.
    Almen, A.
    Ginjaume, M.
    Duch, M. A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 166 - 174
  • [22] Dosimetry of patient and personnel during interventional radiology procedures in Hellas
    Neofotistou, V
    Karoussou, A
    Tomaras, P
    Gerontitis, S
    Balougias, H
    PHYSICA MEDICA, 1997, 13 : 129 - 131
  • [23] Occupational dosimetry in real time. Benefits for interventional radiology
    Vano, E.
    Fernandez, J. M.
    Sanchez, R.
    RADIATION MEASUREMENTS, 2011, 46 (11) : 1262 - 1265
  • [24] Performance assessment of patient dosimetry services and X-ray quality assurance instruments used in diagnostic radiology
    Green, S
    Palethorpe, JE
    Peach, D
    Bradley, DA
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 137 - 152
  • [25] Avoiding adverse events in interventional radiology - a systematic review on the instruments
    Blum, Sophia Freya Ulrike
    Hoffmann, Ralf-Thorsten
    CVIR ENDOVASCULAR, 2024, 7 (01)
  • [26] Avoiding adverse events in interventional radiology – a systematic review on the instruments
    Sophia Freya Ulrike Blum
    Ralf-Thorsten Hoffmann
    CVIR Endovascular, 7
  • [27] COMPARISON OF DOUBLE DOSIMETRY ALGORITHMS FOR ESTIMATING THE EFFECTIVE DOSE IN OCCUPATIONAL DOSIMETRY OF INTERVENTIONAL RADIOLOGY STAFF
    Jarvinen, H.
    Buls, N.
    Clerinx, P.
    Miljanic, S.
    Nikodemova, D.
    Ranogajec-Komor, M.
    Struelens, L.
    d'Errico, F.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 80 - 86
  • [28] Understanding the Basics of Commonly Used Wires in Interventional Radiology
    Pandhi, Mithil B.
    Tyagi, Ravi
    Surabhi, Divya
    Shah, Ketan Y.
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2021, 38 (05) : 560 - 564
  • [29] Temporary Embolic Agents Used in Interventional Radiology: An Update
    Brinckman, M.
    Ray, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [30] Understanding the Basics of Commonly Used Catheters in Interventional Radiology
    Khabbaz, Ramzy C.
    Polikaitis, Kovas
    Niemeyer, Matthew M.
    SEMINARS IN INTERVENTIONAL RADIOLOGY, 2023, 40 (02) : 247 - 252