Analytical expressions for water-to-air stopping-power ratios relevant for accurate dosimetry in particle therapy

被引:22
|
作者
Luhr, Armin [1 ,2 ]
Hansen, David C. [2 ]
Jaekel, Oliver [3 ,4 ]
Sobolevsky, Nikolai [5 ]
Bassler, Niels [1 ,2 ]
机构
[1] Aarhus Univ Hosp, Dept Expt Clin Oncol, DK-8000 Aarhus, Denmark
[2] Univ Aarhus, Dept Phys & Astron, Aarhus, Denmark
[3] German Canc Res Ctr, Dept Med Phys Radiat Oncol, Heidelberg, Germany
[4] Univ Heidelberg Hosp, Heidelberg Ion Beam Therapy Ctr HIT, Heidelberg, Germany
[5] Russian Acad Sci, Inst Nucl Res, Dept Neutron Res, Moscow 117312, Russia
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2011年 / 56卷 / 08期
关键词
HEAVY-ION RADIOTHERAPY; MONTE-CARLO; RADIATION; TRANSPORT; SOLIDS; SHIELD; CODE;
D O I
10.1088/0031-9155/56/8/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In particle therapy, knowledge of the stopping-power ratio (STPR) of the ion beam for water and air is necessary for accurate ionization chamber dosimetry. Earlier work has investigated the STPR for pristine carbon ion beams, but here we expand the calculations to a range of ions (1 <= z <= 18) as well as spread-out Bragg peaks (SOBPs) and provide a theoretical in-depth study with a special focus on the parameter regime relevant for particle therapy. The Monte Carlo transport code SHIELD-HIT is used to calculate complete particle-fluence spectra which are required for determining the STPR according to the recommendations of the International Atomic Energy Agency. The STPR at a depth d depends primarily on the average energy of the primary ions at d rather than on their charge z or absolute position in the medium. However, STPRs for different sets of stopping-power data for water and air recommended by the International Commission on Radiation Units and Measurements are compared, including also the recently revised data for water, yielding deviations up to 2% in the plateau region. In comparison, the influence of the secondary particle spectra on the STPR is about two orders of magnitude smaller in the whole region up till the practical range. The gained insights enable us to propose simple analytical expressions for the STPR for both pristine and SOBPs as a function of penetration depth depending parametrically on the practical range.
引用
收藏
页码:2515 / 2533
页数:19
相关论文
共 35 条
  • [31] WATER-AIR MASS STOPPING POWER RATIOS FOR MEGAVOLTAGE PHOTON AND ELECTRON-BEAMS
    NAHUM, AE
    PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (01): : 24 - 38
  • [32] Variations in energy spectra and water-to-material stopping-power ratios in three-dimensional conformal and intensity-modulated photon fields
    Jang, Si Young
    Liu, H. Helen
    Mohan, Radhe
    Siebers, Jeffrey V.
    MEDICAL PHYSICS, 2007, 34 (04) : 1388 - 1397
  • [33] Monte Carlo calculation of Spencer-Attix and Bragg-Gray stopping-power ratios of tissue-to-air for ISO reference beta sources - an EGSnrc study
    Selvam, T. Palani
    Shrivastava, V
    Bakshi, A. K.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (03)
  • [34] Optimum size of a calibration phantom for x-ray CT to convert the Hounsfield units to stopping power ratios in charged particle therapy treatment planning
    Inaniwa, T.
    Tashima, H.
    Kanematsu, N.
    JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 216 - 224
  • [35] Novel analytical expressions for determining van der Waals interaction between a particle and air-water interface: Unexpected stronger van der Waals force than capillary force
    Du, Yichun
    Bradford, Scott A.
    Shen, Chongyang
    Li, Tiantian
    Bi, Xiaoyuan
    Liu, Dong
    Huang, Yuanfang
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2022, 610 : 982 - 993