Induced Voltage Calculation in Electric Traction Systems: Simplified Methods, Screening Factors, and Accuracy

被引:21
|
作者
Mariscotti, Andrea [1 ]
机构
[1] Univ Genoa, Dept Naval Architecture & Elect Engn, I-16145 Genoa, Italy
关键词
Electromagnetic induction; electromagnetic reactive interference; guideway transportation power systems; power distribution electromagnetic interference; TELECOMMUNICATION CABLES; RAILWAY SYSTEMS; RETURN CURRENT; AC; LINE; PARAMETERS; IMPEDANCE; FREQUENCY; OVERHEAD; EARTH;
D O I
10.1109/TITS.2010.2076327
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In modern electric traction systems, the calculation of induced voltage on internal and external conductors is always required for both interference and people and equipment safety. The International Telegraph and Telephone Consultative Committee (CCITT) method is based on simplified relationships, which are integrated by suitable screening factors (representing and hiding the traction system complexity). Focus is on the determination of these factors and the accuracy, which are evaluated with simulation and experimental data. The considered systems are rail return, return conductor, and autotransformer (AT) 2 x 25-kV traction systems with victim cables of various lengths; the influence of the most relevant electric parameters (soil resistivity and conductance to earth of the return circuit conductors) is considered. The results confirm the relevance of the conductance to earth and of the position of the current injection point. The induced voltage is approximately proportional to the length, with a slight increase for shorter victim cables. The calculated AT screening factor is always smaller than the values suggested by the standards by a factor of 2 in the worst case. For the influence of separation of the inducing and victim circuits, the adopted methods agree in finding a critical distance around 6-8 m; at larger distances, CCITT values are slightly optimistic. Measured results confirm that the CCITT coefficients are all conservative by a factor of 2-4 (except the AT coefficient for total length exposure), whereas the multiconductor transmission line (MTL) results agree with a worst-case margin of 13%.
引用
收藏
页码:201 / 210
页数:10
相关论文
共 50 条
  • [31] A COMPARATIVE-ANALYSIS OF 2 METHODS FOR THE CALCULATION OF ELECTRIC-FIELD-INDUCED PERTURBATIONS TO MOLECULAR VIBRATION
    MARTI, J
    BISHOP, DM
    JOURNAL OF CHEMICAL PHYSICS, 1993, 99 (05): : 3860 - 3864
  • [32] Voltage Difference Residual-Based Open-Circuit Fault Diagnosis Approach for Three-Level Converters in Electric Traction Systems
    Chao, Yang
    Gui, Weihua
    Chen, Zhiwen
    Zhang, Jingrong
    Peng, Tao
    Yang, Chunhua
    Karimi, Hamid Reza
    Ding, Steven X.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (03) : 3012 - 3028
  • [33] Error Estimation and Methods for Improving Accuracy in Measuring the Parameters of Analog Signals in Digital Electric Power Control Systems
    Turygin, Igor G.
    Sergina, Irina G.
    2018 GLOBAL SMART INDUSTRY CONFERENCE (GLOSIC), 2018,
  • [34] Simplified calculation methods for earthquake-induced hydrodynamic added mass of immersed pile caps with different cross-sections
    Zhang, Jiarui
    Shen, Yuting
    Zhou, Chunxu
    Yang, Shaolin
    OCEAN ENGINEERING, 2023, 284
  • [35] Calculation of Load Diagrams and Static Characteristics of Multimotor Electric Drive Systems using the Methods of Equivalent Forces and Reduced Moments
    Semenov, Alexander
    Yakushev, Ilya
    Kharitonov, Yakov
    Shevchuk, Vladislav
    Gracheva, Elena
    Ilyashenko, Svetlana
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (08) : 1537 - 1546
  • [36] Improving the Efficiency of Electric Rolling Stock Operation Through the Use of Adaptive Filtering Methods for High Harmonic Current Components in Traction Drive Systems
    Goolak, S.
    PROBLEMELE ENERGETICII REGIONALE, 2023, (04): : 1 - 13
  • [37] Review On The Calculation Of Surface Electric And Magnetic Fields And Of Geomagnetically Induced Currents In Ground-Based Technological Systems
    Risto Pirjola
    Surveys in Geophysics, 2002, 23 : 71 - 90
  • [38] Review on the calculation of surface electric and magnetic fields and of geomagnetically induced currents in ground-based technological systems
    Pirjola, R
    SURVEYS IN GEOPHYSICS, 2002, 23 (01) : 71 - 90
  • [39] Voltage sag state estimation based on l(1)-norm minimization methods in radial electric power distribution systems
    Blanco-Solano, Jairo
    Kagan, Nelson
    Almeida, Carlos Frederico M.
    Petit-Suarez, Johann F.
    Ordonez-Plata, Gabriel
    UIS INGENIERIAS, 2018, 17 (02): : 309 - 317
  • [40] Analysis and calculation of the dynamic voltage reserve of the converter when working under load in systems of subject regulation by electric drives of direct current
    Dubik, Viktor
    Kamishlov, Vitalii
    Tkach, Oleg
    Horbovy, Oleg
    Mazur, Viktor
    Kupchuk, Ihor
    Pantsyreva, Hanna
    Alieksieieva, Olha
    PRZEGLAD ELEKTROTECHNICZNY, 2024, 100 (05): : 117 - 123