Induced Voltage Calculation in Electric Traction Systems: Simplified Methods, Screening Factors, and Accuracy

被引:21
|
作者
Mariscotti, Andrea [1 ]
机构
[1] Univ Genoa, Dept Naval Architecture & Elect Engn, I-16145 Genoa, Italy
关键词
Electromagnetic induction; electromagnetic reactive interference; guideway transportation power systems; power distribution electromagnetic interference; TELECOMMUNICATION CABLES; RAILWAY SYSTEMS; RETURN CURRENT; AC; LINE; PARAMETERS; IMPEDANCE; FREQUENCY; OVERHEAD; EARTH;
D O I
10.1109/TITS.2010.2076327
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In modern electric traction systems, the calculation of induced voltage on internal and external conductors is always required for both interference and people and equipment safety. The International Telegraph and Telephone Consultative Committee (CCITT) method is based on simplified relationships, which are integrated by suitable screening factors (representing and hiding the traction system complexity). Focus is on the determination of these factors and the accuracy, which are evaluated with simulation and experimental data. The considered systems are rail return, return conductor, and autotransformer (AT) 2 x 25-kV traction systems with victim cables of various lengths; the influence of the most relevant electric parameters (soil resistivity and conductance to earth of the return circuit conductors) is considered. The results confirm the relevance of the conductance to earth and of the position of the current injection point. The induced voltage is approximately proportional to the length, with a slight increase for shorter victim cables. The calculated AT screening factor is always smaller than the values suggested by the standards by a factor of 2 in the worst case. For the influence of separation of the inducing and victim circuits, the adopted methods agree in finding a critical distance around 6-8 m; at larger distances, CCITT values are slightly optimistic. Measured results confirm that the CCITT coefficients are all conservative by a factor of 2-4 (except the AT coefficient for total length exposure), whereas the multiconductor transmission line (MTL) results agree with a worst-case margin of 13%.
引用
收藏
页码:201 / 210
页数:10
相关论文
共 50 条
  • [21] Calculation Method and Influencing Factors of Lightning-induced Voltage on Overhead Distribution Line
    Li, Weiguo
    Xie, Tao
    Zhang, Wen
    Zhang, Zhanlong
    Mei, Daojun
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 420 - 425
  • [22] The accuracy of current density functionals for the calculation of electric field gradients:: A comparison with ab initio methods for HCl and CuCl
    Schwerdtfeger, P
    Pernpointner, M
    Laerdahl, JK
    JOURNAL OF CHEMICAL PHYSICS, 1999, 111 (08): : 3357 - 3364
  • [23] Calculation of electric field and partial discharge activity reduction for covered conductor/high voltage insulator systems
    Ibrahim, Mohamed E.
    Abd-Elhady, Amr M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 144 : 72 - 80
  • [24] Analysis of Factors Influencing the Transmembrane Voltage Induced in Filamentous Fungi by Pulsed Electric Fields
    Feng, Xuebin
    Zhu, Mengyu
    Xu, Jin
    Yin, Wenqing
    Hu, Fei
    MICROORGANISMS, 2019, 7 (09)
  • [26] Calculation of Voltage Unbalance in Transmission Systems Due to AC Railway Operation: A Simplified Methodology Using Network Admittance Matrix
    Stamatopoulos, Athanasios
    Vikelgaard, Henrik
    Khazraj, Hesam
    da Silva, F. Faria
    Bak, Claus Leth
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [27] Loss Minimization of Traction Systems in Battery Electric Vehicles Using Variable DC-link Voltage Technique - Experimental Study
    Liu, Libo
    Li, Boyang
    Goetting, Gunther
    Xiang, Yusheng
    Salem, Qusay
    Hamid, Muhammad
    Xie, Jian
    2020 22ND EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'20 ECCE EUROPE), 2020,
  • [28] Calculation of the Lightning Induced Response on Overhead Transmission Lines based on the Electric Field Representation Methods
    Guo, Jun
    Xie, Yan-zhao
    2019 URSI ASIA-PACIFIC RADIO SCIENCE CONFERENCE (AP-RASC), 2019,
  • [29] Feasibility of power electronic converters for low-voltage (42V) SRM drives in mildly hybrid electric traction systems
    Emadi, A
    IEMDC 2001: IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, 2001, : 585 - 587
  • [30] Sleep apnea screening using simplified systems. Significance of methods beyond six-channel polygraphy
    Glos, Martin
    Triche, Dora
    Schoebel, Christoph
    SOMNOLOGIE, 2021, 25 (02): : 155 - 165