摘要
In modern electric traction systems, the calculation of induced voltage on internal and external conductors is always required for both interference and people and equipment safety. The International Telegraph and Telephone Consultative Committee (CCITT) method is based on simplified relationships, which are integrated by suitable screening factors (representing and hiding the traction system complexity). Focus is on the determination of these factors and the accuracy, which are evaluated with simulation and experimental data. The considered systems are rail return, return conductor, and autotransformer (AT) 2 x 25-kV traction systems with victim cables of various lengths; the influence of the most relevant electric parameters (soil resistivity and conductance to earth of the return circuit conductors) is considered. The results confirm the relevance of the conductance to earth and of the position of the current injection point. The induced voltage is approximately proportional to the length, with a slight increase for shorter victim cables. The calculated AT screening factor is always smaller than the values suggested by the standards by a factor of 2 in the worst case. For the influence of separation of the inducing and victim circuits, the adopted methods agree in finding a critical distance around 6-8 m; at larger distances, CCITT values are slightly optimistic. Measured results confirm that the CCITT coefficients are all conservative by a factor of 2-4 (except the AT coefficient for total length exposure), whereas the multiconductor transmission line (MTL) results agree with a worst-case margin of 13%.
引用
收藏
页码:201 / 210
页数:10
相关论文
共 50 条
  • [1] Computer methods for electromagnetic analysis of electric rail traction systems
    Pozzobon, A
    Pozzobon, P
    COMPUTERS IN RAILWAYS V, VOL 2: RAILWAY TECHNOLOGY AND ENVIRONMENT, 1996, : 413 - 421
  • [2] Development of methods of calculation of traction power supply systems and energy systems feeding them
    Domanskyi, I. V.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2015, (04) : 62 - 68
  • [3] Calculation of electric and magnetic fields in simplified chambers of low-voltage circuit breakers
    Wu, Y
    Rong, MZ
    Li, J
    Lou, JY
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (04) : 1007 - 1010
  • [4] Methods of Calculation of the Reliability of Electric Networks of Electric Power Systems.
    Nevedrov, G.A.
    Izvestiya Vysshikh Uchebnykh Zavedenij i Energeticheskikh Ob''edinenij Sng. Energetika, 1975, (04): : 14 - 18
  • [5] Accuracy verification of impulse voltage measuring systems by convolution methods
    Yutthagowith, P.
    Pattanadech, N.
    Kunakorn, A.
    Phoomvuthisarn, S.
    IPEC: 2005 International Power Engineering Conference, Vols 1 and 2, 2005, : 329 - 333
  • [6] Direct calculation of voltage-stability limit of electric power systems
    Suzuki, Mamoru
    Masegi, Ken
    1600, (111):
  • [7] Quantification of safety factors for simplified heating and cooling demand calculation methods for Vienna
    Sofic, Mario
    Korjenic, Azra
    Bednar, Thomas
    BUILDING SIMULATION, 2011, 4 (03) : 189 - 204
  • [8] Quantification of safety factors for simplified heating and cooling demand calculation methods for Vienna
    Mario Sofic
    Azra Korjenic
    Thomas Bednar
    Building Simulation, 2011, 4 : 189 - 204
  • [9] Improved low voltage solution calculation method for voltage stability assessment of electric power systems
    Castro, CA
    2000 IEEE POWER ENGINEERING SOCIETY WINTER MEETING - VOLS 1-4, CONFERENCE PROCEEDINGS, 2000, : 1180 - 1185
  • [10] ON THE ACCURACY OF ANALYTICAL CALCULATION METHODS IN THE THERMOHYDRODYNAMICS OF 2-PHASE SYSTEMS
    ARUTIUNIAN, GM
    OVSEPIAN, ST
    DOKLADY AKADEMII NAUK SSSR, 1982, 265 (06): : 1367 - 1370