Comparison of high- and low-voltage x-ray mapping of an electronic device

被引:0
|
作者
Small, JA [1 ]
Bright, DS [1 ]
机构
[1] NIST, Surface & Microanal Sci Div, Gaithersburg, MD 20899 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, field-emission gun scanning electron microscopes, FEG-SEMs, with high-brightness electron guns and excellent performance at low electron beam energies (E-0 less than or equal to 5 keV) have become readily available. Concurrently the performance of solid-state x-ray detectors such as the Si-Li detector has improved significantly and with the addition of ultra-thin window materials these devices are easily capable of detecting characteristic x-rays with energies as low as 150 eV. In conventional x-ray mapping the energy of the electron beam is usually 15 keV-25 keV and the maps are acquired with the K, L, and M shell x-ray lines with energies from 1keV to 15 keV. At these electron beam energies, the lateral resolution of the x-ray maps is on the order of 1 mum -3 mum. Reducing the electron beam energy to 5 keV or below and utilizing the K, L, and M lines with energies from 400 eV to 4 keV should significantly improve the lateral resolution of the x-ray maps. In this study, x-ray maps were acquired for SI-K x-rays at 1.74 keV and O-K x-rays at 0.53 keV on a poly Si gate region of a CMOS device. The maps were acquired at a magnification of 70,000 diameters at beam energies of 15 keV and 5 keV. The 15 keV maps showed little or no variation in intensity corresponding to the device structure. In comparison, the intensity variation in the 5 keV maps correlated well with the Si and SiO2 features in the device. In addition the intensity profiles from the 5 keV maps were used to estimate the effective resolution of the Si and O maps at 16nm and 130 nm respectively.
引用
收藏
页码:596 / 600
页数:5
相关论文
共 50 条
  • [41] A high voltage, demountable x-ray tube
    Kliever, WH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1939, 10 (04): : 126 - 128
  • [42] High resolution X-ray mapping in the STEM
    Williams, DB
    Papworth, AJ
    Watanabe, M
    JOURNAL OF ELECTRON MICROSCOPY, 2002, 51 : S113 - S126
  • [43] Quantitative X-ray mapping with high resolution
    Watanabe, M
    Carpenter, DT
    Barmak, K
    Williams, DB
    ELECTRON MICROSCOPY AND ANALYSIS 1997, 1997, (153): : 295 - 298
  • [44] High voltage cathode ray and X-ray tubes and their operation
    Coolidge, W. A.
    Dempster, L. E.
    Tanis, H. E., Jr.
    PHYSICS-A JOURNAL OF GENERAL AND APPLIED PHYSICS, 1931, 1 (01): : 230 - 244
  • [45] CONCERNING A DEVICE AND A METHOD FOR COMPARISON AND CALIBRATION OF EFFECTIVE X-RAY ENERGY AT LOW KV
    STICKLEY, EE
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (01): : 169 - &
  • [46] ELECTRONIC DEVICE FOR SPHERICAL AVERAGING OF X-RAY FIBRE DIAGRAMS
    RULAND, W
    DEWAELHEYNS, A
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1967, 44 (03): : 236 - +
  • [47] Wearable electronic device for X-ray warning and health monitoring
    Haijing Hu
    Wanting Pan
    Yuhong He
    Chenglong Li
    Wei Qu
    Yifan Yang
    Haotong Wei
    Journal of Energy Chemistry, 2024, 99 (12) : 193 - 200
  • [48] Wearable electronic device for X-ray warning and health monitoring
    Hu, Haijing
    Pan, Wanting
    He, Yuhong
    Li, Chenglong
    Qu, Wei
    Yang, Yifan
    Wei, Haotong
    JOURNAL OF ENERGY CHEMISTRY, 2024, 99 : 193 - 200
  • [49] High-efficiency electronic transformer for low-voltage halogen lamp
    Jirasereeamornkul, K
    Boonyaroonate, I
    Chamnongthai, K
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL III: GENERAL & NONLINEAR CIRCUITS AND SYSTEMS, 2003, : 355 - 358
  • [50] Double-input PWM dc/dc converter for high-/low-voltage sources
    Chen, Yaow-Ming
    Liu, Yuan-Chuan
    Lin, Sheng-Hsien
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1538 - 1545