Comparison of high- and low-voltage x-ray mapping of an electronic device

被引:0
|
作者
Small, JA [1 ]
Bright, DS [1 ]
机构
[1] NIST, Surface & Microanal Sci Div, Gaithersburg, MD 20899 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In recent years, field-emission gun scanning electron microscopes, FEG-SEMs, with high-brightness electron guns and excellent performance at low electron beam energies (E-0 less than or equal to 5 keV) have become readily available. Concurrently the performance of solid-state x-ray detectors such as the Si-Li detector has improved significantly and with the addition of ultra-thin window materials these devices are easily capable of detecting characteristic x-rays with energies as low as 150 eV. In conventional x-ray mapping the energy of the electron beam is usually 15 keV-25 keV and the maps are acquired with the K, L, and M shell x-ray lines with energies from 1keV to 15 keV. At these electron beam energies, the lateral resolution of the x-ray maps is on the order of 1 mum -3 mum. Reducing the electron beam energy to 5 keV or below and utilizing the K, L, and M lines with energies from 400 eV to 4 keV should significantly improve the lateral resolution of the x-ray maps. In this study, x-ray maps were acquired for SI-K x-rays at 1.74 keV and O-K x-rays at 0.53 keV on a poly Si gate region of a CMOS device. The maps were acquired at a magnification of 70,000 diameters at beam energies of 15 keV and 5 keV. The 15 keV maps showed little or no variation in intensity corresponding to the device structure. In comparison, the intensity variation in the 5 keV maps correlated well with the Si and SiO2 features in the device. In addition the intensity profiles from the 5 keV maps were used to estimate the effective resolution of the Si and O maps at 16nm and 130 nm respectively.
引用
收藏
页码:596 / 600
页数:5
相关论文
共 50 条
  • [21] Low-voltage energy-dispersive X-ray microanalysis of bulk biological materials
    Echlin, P
    MICROSCOPY AND MICROANALYSIS, 1998, 4 (06) : 577 - 584
  • [22] Stereotactic low-voltage x-ray irradiation for age-related macular degeneration
    Moshfeghi, Darius M.
    Kaiser, Peter K.
    Gertner, Michael
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (02) : 185 - 188
  • [23] A SILICON X-RAY AND GAMMA-RAY DETECTOR FOR ROOM-TEMPERATURE AND LOW-VOLTAGE OPERATION
    YABE, M
    SATO, N
    KAMIJO, H
    TAKECHI, T
    SHIRAISHI, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 193 (1-2): : 63 - 67
  • [24] X-ray photoelectron spectroscopy of high-κ dielectrics
    Mathew, A
    Demirkan, K
    Wang, CG
    Wilk, GD
    Watson, DG
    Opila, RL
    Characterization and Metrology for ULSI Technology 2005, 2005, 788 : 85 - 91
  • [25] DEVICE FOR MEASURING LOW-VOLTAGE SIGNALS IN HIGH-VOLTAGE CIRCUITS
    NIKOLAEVSKII, VG
    CHURIKOV, GM
    KRYZHKO, VV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (05) : 1176 - 1178
  • [26] Industrial applications of high-, medium- and low-voltage arc modelling
    Chevrier, P
    Barrault, M
    Fievet, C
    Maftoul, J
    Fremillon, JM
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (09) : 1346 - 1355
  • [27] High voltage X-ray therapy
    不详
    NATURE, 1936, 138 : 1106 - 1107
  • [28] High voltage x-ray therapy
    不详
    BRITISH MEDICAL JOURNAL, 1936, 1936 : 1271 - 1273
  • [29] Complications and local relapse after intraoperative low-voltage X-ray radiotherapy in breast cancer
    Tejera Hernandez, Ana Alicia
    Vega Benitez, Victor Manuel
    Rocca Cardenas, Juan Carlos
    Ortega Perez, Neith
    Rodriguez Ibarria, Nieves
    Diaz Chico, Juan Carlos
    Garcia-Granados Alayon, Juan Jose
    Perez Correa, Pedro
    Hernandez Hernandez, Juan Ramon
    ANNALS OF SURGICAL TREATMENT AND RESEARCH, 2020, 98 (06) : 299 - 306
  • [30] DEVICE FOR MEASURING LOW-VOLTAGE SIGNALS IN HIGH-VOLTAGE CIRCUITS.
    Nikolaevskii, V.G.
    Churikov, G.M.
    Kryzhko, V.V.
    Instruments and experimental techniques New York, 1982, 25 (5 pt 2): : 1176 - 1178