Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes

被引:158
|
作者
Garjonyte, R [1 ]
Malinauskas, A [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
来源
BIOSENSORS & BIOELECTRONICS | 2000年 / 15卷 / 9-10期
关键词
biosensor; glucose oxidase; polyaniline; Prussian Blue;
D O I
10.1016/S0956-5663(00)00101-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The properties of glucose sensors fabricated by immobilization of glucose oxidase in a layer of electrochemically deposited polyaniline were investigated. Selective amperometric glucose sensors were prepared by immobilization of glucose oxidase on a Prussian Blue-modified platinum electrode in a layer of polyaniline during a one-step electropolymerization procedure from phosphate buffer. The influence of ascorbic acid and acetaminophen was completely eliminated due to impermeability of polyaniline to these substances. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [31] Amperometric glucose biosensor with high sensitivity based on self-assembled Prussian Blue modified electrode
    Liu, Yu
    Chu, Zhenyu
    Zhang, Yannan
    Jin, Wanqin
    ELECTROCHIMICA ACTA, 2009, 54 (28) : 7490 - 7494
  • [32] Polypyrrole based amperometric glucose biosensors
    Singh, Minni
    Kathuroju, Pavan Kumar
    Jampana, Nagaraju
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 143 (01): : 430 - 443
  • [33] Electropolymerization of preoxidized catecholamines on Prussian blue matrix to immobilize glucose oxidase for sensitive amperometric biosensing
    Chen, Chao
    Fu, Yingchun
    Xiang, Canhui
    Xie, Qingji
    Zhang, Qingfang
    Su, Yuhua
    Wang, Lihua
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2726 - 2729
  • [34] THE USE OF REDOX MEDIATOR MODIFIED GLUCOSE-OXIDASE IN AMPEROMETRIC ENZYME ELECTRODES
    BARTLETT, PN
    BRADFORD, VQ
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1990, 333 (1628): : 165 - 165
  • [35] Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode
    Li, T
    Yao, ZH
    Ding, L
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (1-2) : 155 - 160
  • [36] Optimisation of Glucose Biosensors Based on Sol–Gel Entrapment and Prussian Blue-Modified Screen-Printed Electrodes for Real Food Analysis
    Donatella Albanese
    Adriana Sannini
    Francesca Malvano
    Roberto Pilloton
    Marisa Di Matteo
    Food Analytical Methods, 2014, 7 : 1002 - 1008
  • [37] Thermally stable improved first-generation glucose biosensors based on Nafion/glucose-oxidase modified heated electrodes
    Tseng, Ta-Feng
    Yang, Yang-Li
    Chuang, Min-Chieh
    Lou, Shyh-Liang
    Galik, Michal
    Flechsig, Gerd-Uwe
    Wang, Joseph
    ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) : 1819 - 1822
  • [38] DEGREE OF GLUCOSE CONVERSION IN AMPEROMETRIC GLUCOSE-OXIDASE (-MUTAROTASE) MEMBRANE ELECTRODES
    SCHELLER, F
    PFEIFFER, D
    SEYER, I
    KIRSTEIN, D
    SCHULMEISTER, T
    NENTWIG, J
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1983, 11 (2-3): : 155 - 165
  • [39] Amperometric detection of glucose using Prussian blue-graphene oxide modified platinum electrode
    Mohan, A. M. Vinu
    Aswini, K. K.
    Starvin, A. Maria
    Biju, V. M.
    ANALYTICAL METHODS, 2013, 5 (07) : 1764 - 1770
  • [40] An Amperometric Biosensor Based on Glucose Oxidase Immobilized in a Sol-Gel Polyvinyl Alcohol/Silica Hybrid Composite Film on a Prussian Blue Modified Electrode
    Zuo, Shao-Hua
    Zhao, Hong-Li
    Zhang, Ling-Fan
    Yuan, Hui-Hui
    Lan, Min-Bo
    Lawrence, Geoffrey A.
    Wei, Gang