Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes

被引:158
|
作者
Garjonyte, R [1 ]
Malinauskas, A [1 ]
机构
[1] Inst Chem, LT-2600 Vilnius, Lithuania
来源
BIOSENSORS & BIOELECTRONICS | 2000年 / 15卷 / 9-10期
关键词
biosensor; glucose oxidase; polyaniline; Prussian Blue;
D O I
10.1016/S0956-5663(00)00101-9
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The properties of glucose sensors fabricated by immobilization of glucose oxidase in a layer of electrochemically deposited polyaniline were investigated. Selective amperometric glucose sensors were prepared by immobilization of glucose oxidase on a Prussian Blue-modified platinum electrode in a layer of polyaniline during a one-step electropolymerization procedure from phosphate buffer. The influence of ascorbic acid and acetaminophen was completely eliminated due to impermeability of polyaniline to these substances. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [1] Amperometric glucose biosensors based on integration of glucose oxidase onto Prussian blue/carbon nanotubes nanocomposite electrodes
    Zhu, Liande
    Zhai, Jiangli
    Guo, Yingna
    Tian, Chunyuan
    Yang, Ruilan
    ELECTROANALYSIS, 2006, 18 (18) : 1842 - 1846
  • [2] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Bing Yin
    Ruo Yuan
    Yaqing Chai
    Shihong Chen
    Shurui Cao
    Yang Xu
    Ping Fu
    Biotechnology Letters, 2008, 30 : 317 - 322
  • [3] Amperometric glucose biosensors based on layer-by-layer assembly of chitosan and glucose oxidase on the Prussian blue-modified gold electrode
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqing
    Chen, Shihong
    Cao, Shurui
    Xu, Yang
    Fu, Ping
    BIOTECHNOLOGY LETTERS, 2008, 30 (02) : 317 - 322
  • [4] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [5] AMPEROMETRIC BIOSENSORS FOR GLUCOSE BASED ON CARBON PASTE MODIFIED ELECTRODES
    AMINE, A
    KAUFFMANN, JM
    PATRIARCHE, GJ
    TALANTA, 1991, 38 (01) : 107 - 110
  • [6] A HIGH-SENSITIVE GLUCOSE AMPEROMETRIC BIOSENSOR BASED ON PRUSSIAN-BLUE MODIFIED ELECTRODES
    KARYAKIN, AA
    GITELMACHER, OV
    KARYAKINA, EE
    ANALYTICAL LETTERS, 1994, 27 (15) : 2861 - 2869
  • [7] Composite glucose biosensor based on screen-printed electrodes bulk modified with Prussian blue and glucose oxidase
    Pravda, M
    O'Halloran, MP
    Kreuzer, MP
    Guilbault, GG
    ANALYTICAL LETTERS, 2002, 35 (06) : 959 - 970
  • [8] The Development of Reagentless Amperometric Glucose Biosensor Based on Gold Nanostructures, Prussian Blue and Glucose Oxidase
    Sakalauskiene, Laura
    Brasiunas, Benediktas
    Popov, Anton
    Kausaite-Minkstimiene, Asta
    Ramanaviciene, Almira
    BIOSENSORS-BASEL, 2023, 13 (10):
  • [9] Evaluation of amperometric glucose biosensors based on glucose oxidase encapsulated within enzymatically synthesized polyaniline and polypyrrole
    Kausaite-Minkstimiene, Asta
    Mazeiko, Viktor
    Ramanaviciene, Almira
    Ramanavicius, Arunas
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 158 (01) : 278 - 285
  • [10] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)