Experimentally validated x-ray image simulations of 50 μm x-ray PIV tracer particles

被引:10
|
作者
Parker, Jason T. [1 ]
Makiharju, Simo A. [1 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
基金
美国国家科学基金会;
关键词
x-ray; laboratory-scale; particle image velocimetry; tracer particles; particle tracking velocimetry; VELOCIMETRY; SPECTRA; TUBE;
D O I
10.1088/1361-6501/ac4c0d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We evaluate Beer-Lambert (BL) ray-tracing and Monte Carlo N-Particle (MCNP) photon tracking simulations for prediction and comparison of x-ray imaging system performance. These simulation tools can aid the methodical design of laboratory-scale x-ray particle image velocimetry (XPIV) experiments and tracer particles by predicting image quality. Particle image signal-to-noise ratio (SNR) is used as the metric of system performance. Simulated and experiment data of hollow, silver-coated, glass sphere tracer particles (AGSF-33) are compared. As predicted by the simulations, the AGSF-33 particles are visible with a SNR greater than unity in 100 ms exposure time images, demonstrating their potential as x-ray PIV or particle tracking velocimetry (XPTV) tracers. The BL approach predicts the image contrast, is computationally inexpensive, and enables the exploration of a vast parameter space for system design. MCNP simulations, on the other hand, predict experiment images slightly more accurately, but are more than an order of magnitude more computationally expensive than BL simulations. For most practical XPIV system design applications, the higher computational expense of MCNP is likely not justified by the modest accuracy improvement compared to BL.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] A deep X-ray image of M33
    Long, KS
    Charles, PA
    Blair, WP
    Gordon, SM
    ASTROPHYSICAL JOURNAL, 1996, 466 (02): : 750 - &
  • [32] X-ray reflection in a sample of X-ray bright ultraluminous X-ray sources
    Caballero-Garcia, M. D.
    Fabian, A. C.
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2010, 402 (04) : 2559 - 2566
  • [33] Soft X-ray scanning transmission X-ray microscopy (STXM) of actinide particles
    Nilsson, HJ
    Tyliszczak, T
    Wilson, RE
    Werme, L
    Shuh, DK
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (01) : 41 - 47
  • [34] A 62 day X-ray periodicity and an X-ray flare from the ultraluminous X-ray source in M82
    Kaaret, Philip
    Simet, Melanie G.
    Lang, Cornelia C.
    ASTROPHYSICAL JOURNAL, 2006, 646 (01): : 174 - 183
  • [35] Soft X-ray scanning transmission X-ray microscopy (STXM) of actinide particles
    Hans J. Nilsson
    Tolek Tyliszczak
    Richard E. Wilson
    Lars Werme
    David K. Shuh
    Analytical and Bioanalytical Chemistry, 2005, 383 : 41 - 47
  • [36] Efficient x-ray tube simulations
    Mainegra-Hing, Ernesto
    Kawrakow, Iwan
    MEDICAL PHYSICS, 2006, 33 (08) : 2683 - 2690
  • [37] Image x-ray emission converters and microstrip porous dielectric x-ray detector
    Lorikyan, M.P.
    Journal of Applied Physics, 2008, 104 (09):
  • [38] DEPENDENCE OF TRANSMISSION PROPERTIES OF X-RAY IMAGE AMPLIFIERS ON X-RAY INCIDENCE ANGLES
    STAHNKE, I
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1968, : 21 - &
  • [39] Image x-ray emission converters and microstrip porous dielectric x-ray detector
    Lorikyan, M. P.
    JOURNAL OF APPLIED PHYSICS, 2008, 104 (09)
  • [40] Recent advances in X-ray photoconductors for direct conversion X-ray image detectors
    Kasap, S. O.
    Kabir, M. Zahangir
    Rowlands, J. A.
    CURRENT APPLIED PHYSICS, 2006, 6 (03) : 288 - 292