Experimentally validated x-ray image simulations of 50 μm x-ray PIV tracer particles

被引:10
|
作者
Parker, Jason T. [1 ]
Makiharju, Simo A. [1 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
基金
美国国家科学基金会;
关键词
x-ray; laboratory-scale; particle image velocimetry; tracer particles; particle tracking velocimetry; VELOCIMETRY; SPECTRA; TUBE;
D O I
10.1088/1361-6501/ac4c0d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We evaluate Beer-Lambert (BL) ray-tracing and Monte Carlo N-Particle (MCNP) photon tracking simulations for prediction and comparison of x-ray imaging system performance. These simulation tools can aid the methodical design of laboratory-scale x-ray particle image velocimetry (XPIV) experiments and tracer particles by predicting image quality. Particle image signal-to-noise ratio (SNR) is used as the metric of system performance. Simulated and experiment data of hollow, silver-coated, glass sphere tracer particles (AGSF-33) are compared. As predicted by the simulations, the AGSF-33 particles are visible with a SNR greater than unity in 100 ms exposure time images, demonstrating their potential as x-ray PIV or particle tracking velocimetry (XPTV) tracers. The BL approach predicts the image contrast, is computationally inexpensive, and enables the exploration of a vast parameter space for system design. MCNP simulations, on the other hand, predict experiment images slightly more accurately, but are more than an order of magnitude more computationally expensive than BL simulations. For most practical XPIV system design applications, the higher computational expense of MCNP is likely not justified by the modest accuracy improvement compared to BL.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] X-RAY OPTICS + X-RAY MICROANALYSIS
    HEINRICH, KF
    AMERICAN SCIENTIST, 1965, 53 (03) : A382 - &
  • [22] X-Ray Inerferometer with a X-Ray Beamsplitter
    Kitamoto, S.
    Sakata, K.
    Murakami, H.
    Yoshida, Y.
    Seta, H.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [23] X-RAY OPTICS AND X-RAY MICROANALYSIS
    AXON, HJ
    JOURNAL OF THE INSTITUTE OF METALS, 1965, 93 : 607 - &
  • [24] X-RAY OPTICS AND X-RAY ASTRONOMY
    KANTOR, FW
    TRANSACTIONS OF THE NEW YORK ACADEMY OF SCIENCES, 1968, 30 (08): : 1100 - &
  • [25] COPD exacerbations - To X-ray or not to X-ray
    Dewan, NA
    CHEST, 2002, 122 (04) : 1118 - 1121
  • [26] X-ray jets and X-ray plasmoids
    Shibata, K
    PROCEEDINGS OF AN INTERNATIONAL MEETING ON SOLAR JETS AND CORONAL PLUMES, 1998, 421 : 137 - 146
  • [27] X-RAY OPTICS AND X-RAY MICROANALYSIS
    SANDS, DE
    MICROCHEMICAL JOURNAL, 1965, 9 (01) : 100 - &
  • [28] The X-ray outbursts of Be/X-ray transients
    Negueruela, I
    Okazaki, AT
    BE PHENOMENON IN EARLY-TYPE STARS, PROCEEDINGS, 2000, 175 : 713 - 718
  • [29] X-ray Polarimetry of X-ray Pulsars
    Poutanen, Juri
    Tsygankov, Sergey S.
    Forsblom, Sofia V.
    GALAXIES, 2024, 12 (04):
  • [30] GOES M solar X-ray image availability
    Hill, SM
    Barsness, S
    Lewis, LD
    Vickroy, J
    Balch, CC
    Muckle, A
    Pizzo, VJ
    Wilkinson, DC
    McClinton, AT
    17TH INTERNATIONAL CONFERENCE ON INTERACTIVE INFORMATION AND PROCESSING SYSTEMS (IIPS) FOR METEOROLOGY, OCEANOGRAPHY, AND HYDROLOGY, 2001, : 312 - 315