Experimentally validated x-ray image simulations of 50 μm x-ray PIV tracer particles

被引:10
|
作者
Parker, Jason T. [1 ]
Makiharju, Simo A. [1 ]
机构
[1] Univ Calif Berkeley, Dept Mech Engn, Berkeley, CA 94720 USA
基金
美国国家科学基金会;
关键词
x-ray; laboratory-scale; particle image velocimetry; tracer particles; particle tracking velocimetry; VELOCIMETRY; SPECTRA; TUBE;
D O I
10.1088/1361-6501/ac4c0d
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We evaluate Beer-Lambert (BL) ray-tracing and Monte Carlo N-Particle (MCNP) photon tracking simulations for prediction and comparison of x-ray imaging system performance. These simulation tools can aid the methodical design of laboratory-scale x-ray particle image velocimetry (XPIV) experiments and tracer particles by predicting image quality. Particle image signal-to-noise ratio (SNR) is used as the metric of system performance. Simulated and experiment data of hollow, silver-coated, glass sphere tracer particles (AGSF-33) are compared. As predicted by the simulations, the AGSF-33 particles are visible with a SNR greater than unity in 100 ms exposure time images, demonstrating their potential as x-ray PIV or particle tracking velocimetry (XPTV) tracers. The BL approach predicts the image contrast, is computationally inexpensive, and enables the exploration of a vast parameter space for system design. MCNP simulations, on the other hand, predict experiment images slightly more accurately, but are more than an order of magnitude more computationally expensive than BL simulations. For most practical XPIV system design applications, the higher computational expense of MCNP is likely not justified by the modest accuracy improvement compared to BL.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] X-ray PIV measurements of blood flows without tracer particles
    Kim, Guk Bae
    Lee, Sang Joon
    EXPERIMENTS IN FLUIDS, 2006, 41 (02) : 195 - 200
  • [2] X-ray PIV measurements of blood flows without tracer particles
    Guk Bae Kim
    Sang Joon Lee
    Experiments in Fluids, 2006, 41 : 195 - 200
  • [3] Image quality simulations in X-ray mammography
    Di Maria, S.
    Oliva, P.
    Bottigli, U.
    Carpinelli, M.
    Golosio, B.
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA B-BASIC TOPICS IN PHYSICS, 2009, 124 (02): : 205 - 222
  • [4] DEVELOPMENT OF A COMPACT X-RAY PIV SYSTEM AND NEW X-RAY FLOW TRACERS Visualization of Opaque Biofluid Flows using X-ray PIV System
    Lee, Sang Joon
    Jung, Sung Yong
    BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2010, : 32 - 37
  • [5] X-Ray to luminous image conversion in X-Ray image converter tubes
    Kuklev, SV
    Zaidel, IN
    23RD INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, PT 1, 1999, 3516 : 110 - 120
  • [6] DEVELOPING TRACER PARTICLES FOR X-RAY PARTICLE TRACKING VELOCIMETRY
    Drake, Joshua B.
    Kenney, Andrea L.
    Morgan, Timothy B.
    Heindel, Theodore J.
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE 2011, VOL 1, PTS A-D, 2012, : 2679 - 2686
  • [7] MEASUREMENT OF X-RAY IMAGE INTENSIFIER SHARPNESS IN THE X-RAY DEPARTMENT
    LEHERON, JC
    POLETTI, JL
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 93 - 104
  • [8] X-RAY GENERATION AND IMAGE CAPTURE - MONOENERGETIC X-RAY SOURCES
    DESLATTES, RD
    TANG, CM
    ACADEMIC RADIOLOGY, 1995, 2 : S113 - S114
  • [9] TO X-RAY OR NOT TO X-RAY - THAT IS THE QUESTION
    BEDRICK, AD
    CLINICAL PEDIATRICS, 1993, 32 (09) : 520 - 520
  • [10] X-ray server: an online resource for simulations of X-ray diffraction and scattering
    Stepanov, S
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY AND NEUTRON OPTICS, 2004, 5536 : 16 - 26