A Small Range Six-Axis Accelerometer Designed with High Sensitivity DCB Elastic Element

被引:17
|
作者
Sun, Zhibo [1 ,2 ]
Liu, Jinhao [1 ]
Yu, Chunzhan [1 ]
Zheng, Yili [1 ]
机构
[1] Beijing Forestry Univ, Sch Technol, Beijing 100083, Peoples R China
[2] Beihang Univ, Engn Training Ctr, Beijing 102206, Peoples R China
来源
SENSORS | 2016年 / 16卷 / 09期
基金
中国博士后科学基金;
关键词
six-axis accelerometer; parallel mechanism; double cantilever beam; sensitivity analysis; FORCE-TORQUE SENSOR; STEWART-PLATFORM; FORCE/TORQUE SENSOR; STIFFNESS; DYNAMICS; SYSTEM; IDENTIFICATION; TRANSDUCER; BEAM;
D O I
10.3390/s16091552
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a small range six-axis accelerometer (the measurement range of the sensor is +/- g) with high sensitivity DCB (Double Cantilever Beam) elastic element. This sensor is developed based on a parallel mechanism because of the reliability. The accuracy of sensors is affected by its sensitivity characteristics. To improve the sensitivity, a DCB structure is applied as the elastic element. Through dynamic analysis, the dynamic model of the accelerometer is established using the Lagrange equation, and the mass matrix and stiffness matrix are obtained by a partial derivative calculation and a conservative congruence transformation, respectively. By simplifying the structure of the accelerometer, a model of the free vibration is achieved, and the parameters of the sensor are designed based on the model. Through stiffness analysis of the DCB structure, the deflection curve of the beam is calculated. Compared with the result obtained using a finite element analysis simulation in ANSYS Workbench, the coincidence rate of the maximum deflection is 89.0% along the x-axis, 88.3% along the y-axis and 87.5% along the z-axis. Through strain analysis of the DCB elastic element, the sensitivity of the beam is obtained. According to the experimental result, the accuracy of the theoretical analysis is found to be 90.4% along the x-axis, 74.9% along the y-axis and 78.9% along the z-axis. The measurement errors of linear accelerations a(x), a(y) and a(z) in the experiments are 2.6%, 0.6% and 1.31%, respectively. The experiments prove that accelerometer with DCB elastic element performs great sensitive and precision characteristics.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Decoupling Algorithm and Maximum Operation Frequency of a Novel Parallel Type Six-Axis Accelerometer
    You, Jingjing
    Wang, Linkang
    Xi, Fengfeng
    Shen, Jingjin
    IEEE SENSORS JOURNAL, 2020, 20 (21) : 12637 - 12651
  • [32] Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity
    Zhang, Jing
    Su, Yan
    Shi, Qin
    Qiu, An-Ping
    SENSORS, 2015, 15 (12) : 30293 - 30310
  • [33] Development of compact high dynamic range six-axis force sensor with cross-arch structure
    Tamura, Ryuya
    Sakaino, Sho
    Tsuji, Toshiaki
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 3609 - 3614
  • [34] Method of improving the sensitivity of large-range six-axis force/moment sensor using the principle of stress concentration
    Feng, Mei
    Gong, Yanlei
    Han, Zhiwu
    Lu, Xiuquan
    Jin, Xingze
    Li, Peng
    MEASUREMENT, 2022, 199
  • [35] Hexblade positioner: A fast large-range six-axis motion stage
    Yang, Zhidi
    Lee, Ryan
    Hopkins, Jonathan B.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2022, 76 : 199 - 207
  • [36] Method of improving the sensitivity of large-range six-axis force/moment sensor using the principle of stress concentration
    Feng, Mei
    Gong, Yanlei
    Han, Zhiwu
    Lu, Xiuquan
    Jin, Xingze
    Li, Peng
    Measurement: Journal of the International Measurement Confederation, 2022, 199
  • [37] Sensitivity and sensitivity isotropy of an 8/4-4 parallel six-axis force sensor
    Li, Chenggang
    Song, Weishan
    Song, Yong
    SENSOR REVIEW, 2020, 40 (05) : 617 - 627
  • [38] Six-axis force-torque sensor with a large range for biomechanical applications
    Brookhuis, R. A.
    Droogendijk, H.
    de Boer, M. J.
    Sanders, R. G. P.
    Lammerink, T. S. J.
    Wiegerink, R. J.
    Krijnen, G. J. M.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2014, 24 (03)
  • [39] Large range prestressed six-axis force sensor and study on static calibration
    Yao, Jiantao
    Hou, Yulei
    Niu, Jianye
    Chen, Jie
    Zhao, Yongsheng
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2009, 30 (06): : 1233 - 1239
  • [40] Shape optimal design and force sensitivity evaluation of six-axis force sensors
    Chao, LP
    Chen, KT