A Small Range Six-Axis Accelerometer Designed with High Sensitivity DCB Elastic Element

被引:17
|
作者
Sun, Zhibo [1 ,2 ]
Liu, Jinhao [1 ]
Yu, Chunzhan [1 ]
Zheng, Yili [1 ]
机构
[1] Beijing Forestry Univ, Sch Technol, Beijing 100083, Peoples R China
[2] Beihang Univ, Engn Training Ctr, Beijing 102206, Peoples R China
来源
SENSORS | 2016年 / 16卷 / 09期
基金
中国博士后科学基金;
关键词
six-axis accelerometer; parallel mechanism; double cantilever beam; sensitivity analysis; FORCE-TORQUE SENSOR; STEWART-PLATFORM; FORCE/TORQUE SENSOR; STIFFNESS; DYNAMICS; SYSTEM; IDENTIFICATION; TRANSDUCER; BEAM;
D O I
10.3390/s16091552
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes a small range six-axis accelerometer (the measurement range of the sensor is +/- g) with high sensitivity DCB (Double Cantilever Beam) elastic element. This sensor is developed based on a parallel mechanism because of the reliability. The accuracy of sensors is affected by its sensitivity characteristics. To improve the sensitivity, a DCB structure is applied as the elastic element. Through dynamic analysis, the dynamic model of the accelerometer is established using the Lagrange equation, and the mass matrix and stiffness matrix are obtained by a partial derivative calculation and a conservative congruence transformation, respectively. By simplifying the structure of the accelerometer, a model of the free vibration is achieved, and the parameters of the sensor are designed based on the model. Through stiffness analysis of the DCB structure, the deflection curve of the beam is calculated. Compared with the result obtained using a finite element analysis simulation in ANSYS Workbench, the coincidence rate of the maximum deflection is 89.0% along the x-axis, 88.3% along the y-axis and 87.5% along the z-axis. Through strain analysis of the DCB elastic element, the sensitivity of the beam is obtained. According to the experimental result, the accuracy of the theoretical analysis is found to be 90.4% along the x-axis, 74.9% along the y-axis and 78.9% along the z-axis. The measurement errors of linear accelerations a(x), a(y) and a(z) in the experiments are 2.6%, 0.6% and 1.31%, respectively. The experiments prove that accelerometer with DCB elastic element performs great sensitive and precision characteristics.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] FAULT DIAGNOSIS IN A GYROSCOPE-BASED SIX-AXIS ACCELEROMETER
    Li, Chenggang
    Wang, Yan
    Chen, Jing
    You, Jingjing
    Rajnathsing, Hemant
    TRANSACTIONS OF FAMENA, 2018, 42 (03) : 103 - 114
  • [12] Theoretical Research on a Six-Axis Accelerometer for Humanoid Robot Wrist
    Yu, Chunzhan
    Zhang, Xinyi
    Jia, Qingxuan
    Li, Jinliang
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 1411 - +
  • [13] Isotropy analysis of parallel six-axis accelerometer on circular hyperboloids
    Du C.
    Tang J.
    Yu C.
    Yin Q.
    Zheng Y.
    International Journal of Circuits, Systems and Signal Processing, 2020, 14 : 222 - 231
  • [14] Parameters optimization of a six-axis accelerometer based on parallel mechanism
    Yu, Chunzhan
    Liu, Jinhao
    Sun, Zhibo
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2014, 35 (10): : 2216 - 2222
  • [15] Development of a multistage six-axis force sensor with a high dynamic range
    Okumura, Daisuke
    Sakaino, Sho
    Tsuji, Toshiaki
    2017 IEEE 26TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2017, : 1386 - 1391
  • [16] Parameter identification and perturbation algorithm of parallel type six-axis accelerometer
    You J.
    Fu Z.
    Li C.
    Wu H.
    Wang J.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2019, 38 (01): : 134 - 141
  • [17] Forward and Inverse Dynamics of a Six-Axis Accelerometer Based on a Parallel Mechanism
    Wang, Linkang
    You, Jingjing
    Yang, Xiaolong
    Chen, Huaxin
    Li, Chenggang
    Wu, Hongtao
    SENSORS, 2021, 21 (01) : 1 - 22
  • [18] Development of High Dynamic Range Six-Axis Force Sensor with Simple Structure
    Kawahara, Takamasa
    Tsuji, Toshiaki
    JOURNAL OF ROBOTICS AND MECHATRONICS, 2023, 35 (03) : 771 - 779
  • [19] A COMPARATIVE STUDY ON TWO METHODS OF DECOUPLING A SIX-AXIS ACCELEROMETER WITHOUT AND WITH A GYROSCOPE
    Li, Chenggang
    Zhang, Wenyan
    Chen, Jing
    You, Jingjing
    TRANSACTIONS OF FAMENA, 2021, 45 (04) : 71 - 83
  • [20] Error and fault-tolerant processing of parallel type six-axis accelerometer
    You, Jing-Jing
    Li, Cheng-Gang
    Wu, Hong-Tao
    Shen, Jing-Jin
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (09): : 2522 - 2532