Numerical study and performance evaluation of the Maisotsenko cycle cooling tower

被引:24
|
作者
Pandelidis, Demis [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Mech & Power Engn, 27 Wyspianski St, PL-50370 Wroclaw, Poland
关键词
Cooling tower; Maisotsenko cycle; Renewable energy; Mathematical model; Numerical simulation; HEAT-EXCHANGER; FLOW; SIMULATION; SYSTEM;
D O I
10.1016/j.enconman.2020.112735
中图分类号
O414.1 [热力学];
学科分类号
摘要
Following paper presents detail investigation of the Maisotsenko cycle (M-Cycle) cooling tower through numerical modeling. For the purpose of this study, epsilon-NTU model of the M-Cycle cooling tower (MCT) was developed and validated against experimental data. The results of the simulation allowed to analyze the heat and mass transfer process occurring inside the M-Cycle cooling tower and observe its most characteristic and important features. It was confirmed that MCT is able to cool the water below the wet-bulb temperature (which is not achievable by conventional cooling towers), even in very hot and humid conditions (outdoor air temperature of 40 degrees C and humidity ratio of. 20 g.kg(-1)). They also allowed to study the influence of the selected parameters (including inlet air temperature and humidity, inlet water temperature, NTU and heat capacity ratio between water and air) on the cooling tower performance. Critical factors which have highest impact on its effectiveness were established and discussed. The study confirmed high practical potential of using M-Cycle in water cooling applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] NUMERICAL INVESTIGATION OF NONUNIFORM SPRAY EFFECT ON THE COOLING PERFORMANCE OF A LARGE-SCALE COOLING TOWER
    Zhao, Yuanbin
    Chen, Xuehong
    Long, Guoqing
    Sun, Fengzhong
    HEAT TRANSFER RESEARCH, 2018, 49 (01) : 31 - 44
  • [42] Numerical study on the cooling performance of natural draft dry cooling tower with vertical delta radiators under constant heat load
    Zhao Yuanbin
    Sun Fengzhong
    Li Yan
    Long Guoqing
    Yang Zhi
    APPLIED ENERGY, 2015, 149 : 225 - 237
  • [43] EVALUATION OF COOLING TOWER NOISE
    BINCKLEY, JW
    ASHRAE JOURNAL, 1970, 12 (01): : 53 - &
  • [44] Uncertainty Analysis of a Numerical Performance Model for an Inflatable Fabric Evaporative Cooling Tower
    Duong, S.
    Craven, R.
    Garner, S.
    Idem, S.
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 2, 2019, 125 : 461 - 472
  • [45] Critical evaluation of the thermal performance analysis of a new cooling tower prototype
    Navarro, P.
    Ruiz, J.
    Hernandez, M.
    Kaiser, A. S.
    Lucas, M.
    APPLIED THERMAL ENGINEERING, 2022, 213
  • [46] Evaluation of thermal performance for natural and forced draft wet cooling tower
    Al-Dulaimi, M. J.
    Kareem, F. A.
    Hamad, F. A.
    JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES, 2019, 13 (04) : 6007 - 6021
  • [47] Research on the development and performance evaluation of drift eliminator for seawater cooling tower
    Li, Xue
    Zhang, Lianqiang
    Yi, Qingwen
    Wang, Yinzhong
    Li, Zhijie
    Guo, Hao
    Yin, Jianhua
    DESALINATION AND WATER TREATMENT, 2018, 119 : 125 - 129
  • [48] Evaluation of wet cooling tower replacement by Heller cooling tower in a power plant
    Malekmohamadi, Mohamad Hasan
    Ahmadikia, Hossein
    Golmohamadi, Siavash
    Khodadadi, Hamed
    ARCHIVE OF MECHANICAL ENGINEERING, 2023, 70 (01) : 129 - 149
  • [49] Methodology for evaluation of cooling tower performance - Part 1: Description of the methodology
    Smrekar, J.
    Kustrin, I.
    Oman, J.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (11) : 3257 - 3264
  • [50] Parametric study of closed wet cooling tower thermal performance
    Qasim, S. M.
    Hayder, M. J.
    MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING V, 2017, 227