Numerical study and performance evaluation of the Maisotsenko cycle cooling tower

被引:24
|
作者
Pandelidis, Demis [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Mech & Power Engn, 27 Wyspianski St, PL-50370 Wroclaw, Poland
关键词
Cooling tower; Maisotsenko cycle; Renewable energy; Mathematical model; Numerical simulation; HEAT-EXCHANGER; FLOW; SIMULATION; SYSTEM;
D O I
10.1016/j.enconman.2020.112735
中图分类号
O414.1 [热力学];
学科分类号
摘要
Following paper presents detail investigation of the Maisotsenko cycle (M-Cycle) cooling tower through numerical modeling. For the purpose of this study, epsilon-NTU model of the M-Cycle cooling tower (MCT) was developed and validated against experimental data. The results of the simulation allowed to analyze the heat and mass transfer process occurring inside the M-Cycle cooling tower and observe its most characteristic and important features. It was confirmed that MCT is able to cool the water below the wet-bulb temperature (which is not achievable by conventional cooling towers), even in very hot and humid conditions (outdoor air temperature of 40 degrees C and humidity ratio of. 20 g.kg(-1)). They also allowed to study the influence of the selected parameters (including inlet air temperature and humidity, inlet water temperature, NTU and heat capacity ratio between water and air) on the cooling tower performance. Critical factors which have highest impact on its effectiveness were established and discussed. The study confirmed high practical potential of using M-Cycle in water cooling applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] A numerical study of interacting buoyant cooling-tower plumes
    Bornoff, RB
    Mokhtarzadeh-Dehghan, MR
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (03) : 589 - 598
  • [32] Numerical Simulation of the Performance Characteristics of the Hybrid Closed Circuit Cooling Tower
    Sarker, M. M. A.
    Kim, E.
    Moon, C. G.
    Yoon, J. I.
    NONLINEAR ANALYSIS-MODELLING AND CONTROL, 2008, 13 (01): : 89 - 101
  • [33] Performance investigation of a M (Maisotsenko)-cycle cross-flow heat exchanger used for indirect evaporative cooling
    Anisimov, Sergey
    Pandelidis, Demis
    Jedlikowski, Andrzej
    Polushkin, Vitaliy
    ENERGY, 2014, 76 : 593 - 606
  • [34] Design optimisation and performance appraisal of a combined cooling, heating and power system primed with Maisotsenko combustion turbine cycle
    Zhu, Guangya
    Chow, T. T.
    Fong, K. F.
    Lee, C. K.
    Luo, X. J.
    ENERGY CONVERSION AND MANAGEMENT, 2018, 177 : 91 - 106
  • [35] NUMERICAL STUDY OF WIND FLOW OVER A COOLING-TOWER
    BERGSTROM, DJ
    DERKSEN, D
    REZKALLAH, KS
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1993, 46-7 : 657 - 664
  • [36] Numerical simulation study on blasting demolition for hyperbolic cooling tower
    Li, S.-L. (lsl@cumtb.edu.cn), 1600, Beijing Institute of Technology (34):
  • [37] Performance study of the Maisotsenko Cycle heat exchangers in different air-conditioning applications
    Pandelidis, Demis
    Anisimov, Sergey
    Worek, William M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 207 - 221
  • [38] Comparative evaluation of hybrid (dry/wet) cooling tower performance
    Asvapoositkul, Wanchai
    Kuansathan, Mantheerapol
    APPLIED THERMAL ENGINEERING, 2014, 71 (01) : 83 - 93
  • [39] Comparative evaluation of hybrid (dry/wet) cooling tower performance
    Asvapoositkul, W. (wanchai.asv@kmutt.ac.th), 1600, Elsevier Ltd (71):
  • [40] Numerical study and optimization of the cross-flow Maisotsenko cycle indirect evaporative air cooler
    Pandelidis, Demis
    Anisimov, Sergey
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 103 : 1029 - 1041