Targeting Accuracy of the Subthalamic Nucleus in Deep Brain Stimulation Surgery: Comparison Between 3 T T2-Weighted Magnetic Resonance Imaging and Microelectrode Recording Results

被引:17
|
作者
Nowacki, Andreas [1 ]
Debove, Ines [2 ]
Fiechter, Michael [1 ]
Rossi, Frederic [1 ]
Oertel, Markus Florian [1 ]
Wiest, Roland [3 ]
Schupbach, Michael [2 ]
Pollo, Claudio [1 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurosurg, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Dept Diagnost & Intervent Neuroradiol, Bern, Switzerland
关键词
DBS; Microelectrode recording; Targeting accuracy; ADVANCED PARKINSONS-DISEASE; MRI; LOCALIZATION; ELECTRODE; IMPLANTATION; LOCATIONS; DYSTONIA; OUTCOMES;
D O I
10.1093/ons/opx175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Targeting accuracy in deep brain stimulation (DBS) surgery can be defined as the level of accordance between selected and anatomic real target reflected by characteristic electrophysiological results of microelectrode recording (MER). OBJECTIVE: To determine the correspondence between the preoperative predicted target based on modern 3-T magnetic resonance imaging (MRI) and intraoperative MER results separately on the initial and consecutive second side of surgery. METHODS: Retrospective cohort study of 86 trajectories of DBS electrodes implanted into the subthalamic nucleus (STN) of patients with Parkinson's disease. The entrance point of the electrode into the STN and the length of the electrode trajectory crossing the STN were determined by intraoperative MER findings and 3 T T2-weighted magnetic resonance images with 1-mm slice thickness. RESULTS: Average difference between MRI- and MER-based trajectory lengths crossing the STN was 0.28 +/- 1.02 mm (95% CI: -0.51 to -0.05 mm). There was a statistically significant difference between the MRI- and MER-based entry points on the initial and second side of surgery (P = .04). Forty-three percent of the patients had a difference of more than +/- 1 mm of the MRI-based-predicted and the MER-based-determined entry points into the STN with values ranging from -3.0 to +/- 4.5 mm. CONCLUSION: STN MRI-based targeting is accurate in the majority of cases on the first and second side of surgery. in 43% of implanted electrodes, we found a relevant deviation of more than 1 mm, supporting the concept of MER as an important tool to guide and optimize targeting and electrode placement.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [41] Hyperintense Uterine Myometrial Masses on T2-Weighted Magnetic Resonance Imaging: Differentiation With Diffusion-Weighted Magnetic Resonance Imaging
    Takeuchi, Mayumi
    Matsuzaki, Kenji
    Nishitani, Hiromu
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (06) : 834 - 837
  • [42] Evaluation of a Deep Learning Reconstruction for High-Quality T2-Weighted Breast Magnetic Resonance Imaging
    Allen, Timothy J.
    Bancroft, Leah C. Henze
    Unal, Orhan
    Estkowski, Lloyd D.
    Cashen, Ty A.
    Korosec, Frank
    Strigel, Roberta M.
    Kelcz, Frederick
    Fowler, Amy M.
    Gegios, Alison
    Thai, Janice
    Lebel, R. Marc
    Holmes, James H.
    TOMOGRAPHY, 2023, 9 (05) : 1949 - 1964
  • [43] Final Electrode Position in Subthalamic Nucleus Deep Brain Stimulation Surgery: A Comparison of Indirect and Direct Targeting Methods
    Tonge, Mehmet
    Kocabicak, Ersoy
    Ackermans, Linda
    Kuijf, Mark
    Temel, Yasin
    TURKISH NEUROSURGERY, 2016, 26 (06) : 900 - 903
  • [44] Targeting the subthalamic nucleus for deep brain stimulation - a comparative study between magnetic resonance images alone and fusion with computed tomographic images
    Chen, S. -Y.
    Tsai, S. -T.
    Lin, S. -H.
    Pan, Y. -H.
    Hung, H. -Y.
    MOVEMENT DISORDERS, 2008, 23 (01) : S125 - S126
  • [45] Targeting the subthalamic nucleus for deep brain stimulation - A comparative study between magnetic resonance images alone and the fusion with computed topographic Images
    Chen, S. -Y.
    Tsai, S. -T.
    Lin, S. -H.
    MOVEMENT DISORDERS, 2009, 24 : S460 - S461
  • [46] T2-WEIGHTED AND DIFFUSION-WEIGHTED MAGNETIC-RESONANCE-IMAGING OF A FOCAL ISCHEMIC LESION IN RAT-BRAIN
    VANBRUGGEN, N
    CULLEN, BM
    KING, MD
    DORAN, M
    WILLIAMS, SR
    GADIAN, DG
    CREMER, JE
    STROKE, 1992, 23 (04) : 576 - 582
  • [47] SIGNS OF PATELLAR CHONDROMALACIA ON SAGITTAL T2-WEIGHTED MAGNETIC-RESONANCE-IMAGING
    DESMET, AA
    MONU, JUV
    FISHER, DR
    KEENE, JS
    GRAF, BK
    SKELETAL RADIOLOGY, 1992, 21 (02) : 103 - 105
  • [48] Measuring Muscle Activity in Sprinters Using T2-Weighted Magnetic Resonance Imaging
    Yoshimoto, Takaya
    Chiba, Yoshihiro
    Ohnuma, Hayato
    Yanaka, Takuya
    Sugisaki, Norihide
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2022, 17 (05) : 774 - 779
  • [49] Deep-learning-based segmentation of perivascular spaces on T2-Weighted 3T magnetic resonance images
    Cai, Die
    Pan, Minmin
    Liu, Chenyuan
    He, Wenjie
    Ge, Xinting
    Lin, Jiaying
    Li, Rui
    Liu, Mengting
    Xia, Jun
    FRONTIERS IN AGING NEUROSCIENCE, 2024, 16
  • [50] Toxicity and T2-Weighted Magnetic Resonance Imaging Potentials of Holmium Oxide Nanoparticles
    Atabaev, Timur Sh.
    Shin, Yong Cheol
    Song, Su-Jin
    Han, Dong-Wook
    Nguyen Hoa Hong
    NANOMATERIALS, 2017, 7 (08):