Targeting Accuracy of the Subthalamic Nucleus in Deep Brain Stimulation Surgery: Comparison Between 3 T T2-Weighted Magnetic Resonance Imaging and Microelectrode Recording Results

被引:17
|
作者
Nowacki, Andreas [1 ]
Debove, Ines [2 ]
Fiechter, Michael [1 ]
Rossi, Frederic [1 ]
Oertel, Markus Florian [1 ]
Wiest, Roland [3 ]
Schupbach, Michael [2 ]
Pollo, Claudio [1 ]
机构
[1] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurosurg, Bern, Switzerland
[2] Univ Bern, Univ Hosp Bern, Inselspital, Dept Neurol, Bern, Switzerland
[3] Univ Bern, Univ Hosp Bern, Inselspital, Dept Diagnost & Intervent Neuroradiol, Bern, Switzerland
关键词
DBS; Microelectrode recording; Targeting accuracy; ADVANCED PARKINSONS-DISEASE; MRI; LOCALIZATION; ELECTRODE; IMPLANTATION; LOCATIONS; DYSTONIA; OUTCOMES;
D O I
10.1093/ons/opx175
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Targeting accuracy in deep brain stimulation (DBS) surgery can be defined as the level of accordance between selected and anatomic real target reflected by characteristic electrophysiological results of microelectrode recording (MER). OBJECTIVE: To determine the correspondence between the preoperative predicted target based on modern 3-T magnetic resonance imaging (MRI) and intraoperative MER results separately on the initial and consecutive second side of surgery. METHODS: Retrospective cohort study of 86 trajectories of DBS electrodes implanted into the subthalamic nucleus (STN) of patients with Parkinson's disease. The entrance point of the electrode into the STN and the length of the electrode trajectory crossing the STN were determined by intraoperative MER findings and 3 T T2-weighted magnetic resonance images with 1-mm slice thickness. RESULTS: Average difference between MRI- and MER-based trajectory lengths crossing the STN was 0.28 +/- 1.02 mm (95% CI: -0.51 to -0.05 mm). There was a statistically significant difference between the MRI- and MER-based entry points on the initial and second side of surgery (P = .04). Forty-three percent of the patients had a difference of more than +/- 1 mm of the MRI-based-predicted and the MER-based-determined entry points into the STN with values ranging from -3.0 to +/- 4.5 mm. CONCLUSION: STN MRI-based targeting is accurate in the majority of cases on the first and second side of surgery. in 43% of implanted electrodes, we found a relevant deviation of more than 1 mm, supporting the concept of MER as an important tool to guide and optimize targeting and electrode placement.
引用
收藏
页码:66 / 71
页数:6
相关论文
共 50 条
  • [21] Subthalamic nucleus deep brain stimulation for Parkinson's disease using magnetic resonance images for localization with and without microelectrode recording: A comparative study of outcome
    Chen, S
    Chou, Y
    Lin, S
    Hsin, Y
    Lin, S
    Lee, C
    MOVEMENT DISORDERS, 2004, 19 : S286 - S286
  • [22] Susceptibility-Weighted MRI Approximates Intraoperative Microelectrode Recording During Deep Brain Stimulation of the Subthalamic Nucleus for Parkinson's Disease
    Budnick, Hailey C.
    Schneider, Dylan
    Zauber, S. Elizabeth
    Witt, Thomas C.
    Gupta, Kunal
    WORLD NEUROSURGERY, 2024, 181 : e346 - e355
  • [23] Subthalamic nucleus deep brain stimulation for Parkinson's disease: Magnetic resonance imaging targeting using visible anatomical landmarks
    Pollo, C
    Meuli, R
    Maeder, P
    Vingerhoets, F
    Ghika, J
    Villemure, JG
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2003, 80 (1-4) : 76 - 81
  • [24] Relative Contribution of Magnetic Resonance Imaging, Microelectrode Recordings, and Awake Test Stimulation in Final Lead Placement during Deep Brain Stimulation Surgery of the Subthalamic Nucleus in Parkinson's Disease
    Frequin, Henrieke L.
    Bot, Maarten
    Dilai, Jose
    Scholten, Marije N.
    Postma, Miranda
    Bour, Lodewijk J.
    Contarino, Maria Fiorella
    de Bie, Rob M. A.
    Schuurman, P. Rick
    van den Munckhof, Pepijn
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2020, 98 (02) : 118 - 128
  • [25] Accuracy of subthalamic nucleus targeting by T2, FLAIR and SWI-3-Tesla MRI confirmed by microelectrode recordings
    Witold H. Polanski
    Klaus D. Martin
    Kay Engellandt
    Rüdiger von Kummer
    Lisa Klingelhoefer
    Mareike Fauser
    Alexander Storch
    Gabriele Schackert
    Stephan B. Sobottka
    Acta Neurochirurgica, 2015, 157 : 479 - 486
  • [26] Hybrid Nanotrimers for Dual T1 and T2-Weighted Magnetic Resonance Imaging
    Cheng, Kai
    Yang, Meng
    Zhang, Ruiping
    Qin, Chunxia
    Su, Xinhui
    Cheng, Zhen
    ACS NANO, 2014, 8 (10) : 9884 - 9896
  • [27] Accuracy of subthalamic nucleus targeting by T2, FLAIR and SWI-3-Tesla MRI confirmed by microelectrode recordings
    Polanski, Witold H.
    Martin, Klaus D.
    Engellandt, Kay
    von Kummer, Ruediger
    Klingelhoefer, Lisa
    Fauser, Mareike
    Storch, Alexander
    Schackert, Gabriele
    Sobottka, Stephan B.
    ACTA NEUROCHIRURGICA, 2015, 157 (03) : 479 - 486
  • [28] Reactive sclerosis: Hyperintense appearance on T2-weighted magnetic resonance imaging
    Kanberoglu, K
    Kantarci, F
    Yilmaz, MH
    ACTA RADIOLOGICA, 2005, 46 (07) : 708 - 715
  • [29] Automatic Brain Tumor Detection in T2-weighted Magnetic Resonance Images
    Dvorak, P.
    Kropatsch, W. G.
    Bartusek, K.
    MEASUREMENT SCIENCE REVIEW, 2013, 13 (05): : 223 - 230
  • [30] Neurotransmitter-Responsive Nanosensors for T2-Weighted Magnetic Resonance Imaging
    Hsieh, Vivian
    Okada, Satoshi
    Wei, He
    Garcia-Alvarez, Isabel
    Barandov, Ali
    Alvarado, Santiago Recuenco
    Ohlendorf, Robert
    Fan, Jingxuan
    Ortega, Athena
    Jasanoff, Alan
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2019, 141 (40) : 15751 - 15754