Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al4V alloy after different polishing protocols

被引:74
|
作者
Guilherme, AS
Henriques, GEP
Zavanelli, RA
Mesquita, MF
机构
[1] UNICAMP, Dept Prosthodont, Piracicaba Dent Sch, Sao Paulo, Brazil
[2] Fed Univ Goias, Coll Dent, Dept Prosthodont, Goiania, Go, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2005年 / 93卷 / 04期
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/j.prosdent.2005.01.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Surface quality of cast metal is directly related to service performance under fatigue stress. Surface heterogeneities resulting from either finishing or polishing processes or by corrosive agents Such as fluoridated solutions, can negatively affect fatigue life. Cast titanium frameworks arc difficult to polish, and ail accepted polishing protocol has not been established. Purpose. This study evaluated and compared surface roughness of cast commercially pure titanium (CP Ti) and Ti-6Al-4V alloy submitted to conventional or electrolytic polishing, correlating the results with corrosion-fatigue strength testing performed in artificial fluoridated saliva. Specimens were also tested in air at room temperature to evaluate the effectiveness of the corrosion-fatigue test model. Material and methods. For cacti metal, 40 dumb-bell-shaped rods, 2.3 mm in diameter at the central segment, were cast. Conventional polishing was performed on 20 specimens of cacti metal following the manufacturer's instructions. A Source of continuous electrical current was used for electrolytic polishing of the other 20 specimens of each metal, which were immersed in an electrolytic solution containing 5% fluoridric acid, 35% nitric acid, and 60% distilled water. Surface roughness, Ka (mu m), was measured with a profilometer, and fatigue tests were carried out with a universal testing machine using a load 30% lower than the 0.2% offset yield strength. After failure, the fractured surfaces were examined using scanning electron microscopy. Surface roughness means were analyzed with a 2-way analysis of variance and the Tukey multiple comparisons test (alpha=.05). Results. Electrolytic polishing (0.24 +/- 0.05 mu m) provided significantly (P <.05) lower surface roughness values than conventional polishing (0.032 +/- 0.06 mu m). Regardless of the polishing protocol, surface roughness of Ti-6Al-4V alloy (0.25 +/- 0.06 mu m) was significantly lower (P <.05) than that of CP Ti (0.31 +/- 0.05 mu m), and the fluoridated environment did not influence fatigue performance. There was no correlation between fatigue performance and surface roughness. Conclusion. Surface roughness of Ti-6Al-4V was significantly lower than that of CP Ti. For cast titanium frameworks, the electrolytic polishing regimen was found to be more effective than the manufacturer's polishing instructions with abrasives and rotary instruments. After polishing, differences in surface roughness values did not affect corrosion-fatigue performance.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [31] Effect of Surface Roughness on Fatigue Strength of Ti-6Al-4V Alloy Manufactured by Additive Manufacturing
    Nakatani, Masanori
    Masuo, Hiroshige
    Tanaka, Yuzo
    Murakami, Yukitaka
    FATIGUE DESIGN 2019, INTERNATIONAL CONFERENCE ON FATIGUE DESIGN, 8TH EDITION, 2019, 19 : 294 - 301
  • [32] Surface roughness effect on multiaxial fatigue behavior of additively manufactured Ti6Al4V alloy
    Renzo D.A.
    Maletta C.
    Sgambitterra E.
    Furgiuele F.
    Berto F.
    International Journal of Fatigue, 2022, 163
  • [33] Effect Of Surface Roughness On The Fatigue Life Of Laser Additive Manufactured Ti6al4v Alloy
    Bača, Adrián
    Konečná, Radomila
    Nicoletto, Gianni
    Kunz, Ludvík
    Manufacturing Technology, 2015, 15 (04): : 4 - 4
  • [34] EFFECT OF SURFACE ROUGHNESS ON VERY HIGH CYCLE FATIGUE BEHAVIOR OF Ti-6Al-4V ALLOY
    Zhu Lina
    Deng Caiyan
    Wang Dongpo
    Hu Shengsun
    ACTA METALLURGICA SINICA, 2016, 52 (05) : 583 - 591
  • [35] NEW FLOW-STRESS EQUATION OF TI-6AL4V ALLOY
    YOSHINO, M
    SHIRAKASHI, T
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1995, 48 (1-4) : 179 - 186
  • [36] Fit of cast commercially pure titanium and Ti-6Al-4V alloy crowns before and after marginal refinement by electrical discharge machining
    Contreras, EFR
    Henriques, GEP
    Giolo, SR
    Nobilo, MAA
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 88 (05): : 467 - 472
  • [37] Selective and noncontaminated surface polishing of medical Ti-6Al-4V titanium alloy by laser chemical processing
    Shao, Yong
    Sun, Shufeng
    Wang, Pingping
    Zhang, Fengyun
    Wang, Xi
    Monka, Peter Pavol
    Liu, Jixin
    Kim, Dongsik
    OPTICAL ENGINEERING, 2022, 61 (11)
  • [38] Surface polishing of additively manufactured Ti6Al4V titanium alloy by using a nanosecond pulse laser
    Jaritngam, Pakin
    Saetang, Viboon
    Qi, Huan
    Dumkum, Chaiya
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2023, 127 (7-8): : 3463 - 3480
  • [39] Surface polishing of additively manufactured Ti6Al4V titanium alloy by using a nanosecond pulse laser
    Pakin Jaritngam
    Viboon Saetang
    Huan Qi
    Chaiya Dumkum
    The International Journal of Advanced Manufacturing Technology, 2023, 127 : 3463 - 3480
  • [40] Effect of surface contamination on adhesive bonding of cast pure titanium and Ti-6Al-4V alloy
    Watanabe, I
    Watanabe, E
    Yoshida, K
    Okabe, T
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (03): : 270 - 276