Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al4V alloy after different polishing protocols

被引:74
|
作者
Guilherme, AS
Henriques, GEP
Zavanelli, RA
Mesquita, MF
机构
[1] UNICAMP, Dept Prosthodont, Piracicaba Dent Sch, Sao Paulo, Brazil
[2] Fed Univ Goias, Coll Dent, Dept Prosthodont, Goiania, Go, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2005年 / 93卷 / 04期
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/j.prosdent.2005.01.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Surface quality of cast metal is directly related to service performance under fatigue stress. Surface heterogeneities resulting from either finishing or polishing processes or by corrosive agents Such as fluoridated solutions, can negatively affect fatigue life. Cast titanium frameworks arc difficult to polish, and ail accepted polishing protocol has not been established. Purpose. This study evaluated and compared surface roughness of cast commercially pure titanium (CP Ti) and Ti-6Al-4V alloy submitted to conventional or electrolytic polishing, correlating the results with corrosion-fatigue strength testing performed in artificial fluoridated saliva. Specimens were also tested in air at room temperature to evaluate the effectiveness of the corrosion-fatigue test model. Material and methods. For cacti metal, 40 dumb-bell-shaped rods, 2.3 mm in diameter at the central segment, were cast. Conventional polishing was performed on 20 specimens of cacti metal following the manufacturer's instructions. A Source of continuous electrical current was used for electrolytic polishing of the other 20 specimens of each metal, which were immersed in an electrolytic solution containing 5% fluoridric acid, 35% nitric acid, and 60% distilled water. Surface roughness, Ka (mu m), was measured with a profilometer, and fatigue tests were carried out with a universal testing machine using a load 30% lower than the 0.2% offset yield strength. After failure, the fractured surfaces were examined using scanning electron microscopy. Surface roughness means were analyzed with a 2-way analysis of variance and the Tukey multiple comparisons test (alpha=.05). Results. Electrolytic polishing (0.24 +/- 0.05 mu m) provided significantly (P <.05) lower surface roughness values than conventional polishing (0.032 +/- 0.06 mu m). Regardless of the polishing protocol, surface roughness of Ti-6Al-4V alloy (0.25 +/- 0.06 mu m) was significantly lower (P <.05) than that of CP Ti (0.31 +/- 0.05 mu m), and the fluoridated environment did not influence fatigue performance. There was no correlation between fatigue performance and surface roughness. Conclusion. Surface roughness of Ti-6Al-4V was significantly lower than that of CP Ti. For cast titanium frameworks, the electrolytic polishing regimen was found to be more effective than the manufacturer's polishing instructions with abrasives and rotary instruments. After polishing, differences in surface roughness values did not affect corrosion-fatigue performance.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [21] Influence of milling stability on machined surface integrity and fatigue performance of Ti-6Al-4V titanium alloy
    Li, Mengyu
    Zhao, Wei
    Li, Liang
    He, Ning
    Stepan, Gabor
    ENGINEERING FAILURE ANALYSIS, 2025, 168
  • [22] Surface polishing and modification of Ti-6Al-4V alloy by shear thickening polishing
    Wang, Jiahuan
    Zhou, Yu
    Qiao, Zhen
    Goel, Saurav
    Wang, Jinhu
    Wang, Xu
    Chen, Hongyu
    Yuan, Julong
    Lyu, Binghai
    SURFACE & COATINGS TECHNOLOGY, 2023, 468
  • [23] Strain localization during tensile Hopkinson bar testing of commercially pure titanium and Ti6Al4V titanium alloy
    Mocko, Wojciech
    Kruszka, Leopold
    Brodecki, Adam
    DYMAT 2015 - 11TH INTERNATIONAL CONFERENCE ON THE MECHANICAL AND PHYSICAL BEHAVIOUR OF MATERIALS UNDER DYNAMIC LOADING, 2015, 94
  • [24] Surface integrity of ultra-precision diamond turned Ti (commercially pure) and Ti alloy (Ti-6Al-4V)
    Colafemina, J. P.
    Jasinevicius, R. G.
    Duduch, J. G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2007, 221 (06) : 999 - 1006
  • [25] Predictive Modeling of the Ti6Al4V Alloy Surface Roughness
    Tsourveloudis, Nikos C.
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2010, 60 (3-4) : 513 - 530
  • [26] Modelling and Simulation of Surface Roughness during the Turning Operation of Titanium Alloy (Ti6Al4V)
    Daniyan, Ilesanmi
    Fameso, Festus
    Mpofu, Khumbulani
    Uchegbu, Ikenna Damian
    2022 IEEE 13TH INTERNATIONAL CONFERENCE ON MECHANICAL AND INTELLIGENT MANUFACTURING TECHNOLOGIES (ICMIMT 2022), 2022, : 176 - 181
  • [27] Predictive Modeling of the Ti6Al4V Alloy Surface Roughness
    Nikos C. Tsourveloudis
    Journal of Intelligent & Robotic Systems, 2010, 60 : 513 - 530
  • [28] Diffusion bonding of γ-TiAl alloy to Ti-6Al4V alloy under hot pressure
    Wang, Xiu-feng
    Ma, Mo
    Liu, Xue-bin
    Wu, Xue-qing
    Tan, Chao-gui
    Shi, Rong-kai
    Lin, Jiang-guo
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2006, 16 (05) : 1059 - 1063
  • [29] Surface integrity after pickling and anodization of Ti-6Al-4V titanium alloy
    Vermesse, Eric
    Mabru, Catherine
    Arurault, Laurent
    APPLIED SURFACE SCIENCE, 2013, 285 : 629 - 637
  • [30] Tribological performance of SS 316L, commercially pure Titanium, and Ti6Al4V in different solutions for biomedical applications
    Pandey, Anurag Kumar
    Kumar, Avinash
    Kumar, Rupesh
    Gautam, R.K.
    Behera, C.K.
    Materials Today: Proceedings, 2023, 78