Surface roughness and fatigue performance of commercially pure titanium and Ti-6Al4V alloy after different polishing protocols

被引:74
|
作者
Guilherme, AS
Henriques, GEP
Zavanelli, RA
Mesquita, MF
机构
[1] UNICAMP, Dept Prosthodont, Piracicaba Dent Sch, Sao Paulo, Brazil
[2] Fed Univ Goias, Coll Dent, Dept Prosthodont, Goiania, Go, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2005年 / 93卷 / 04期
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/j.prosdent.2005.01.010
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Surface quality of cast metal is directly related to service performance under fatigue stress. Surface heterogeneities resulting from either finishing or polishing processes or by corrosive agents Such as fluoridated solutions, can negatively affect fatigue life. Cast titanium frameworks arc difficult to polish, and ail accepted polishing protocol has not been established. Purpose. This study evaluated and compared surface roughness of cast commercially pure titanium (CP Ti) and Ti-6Al-4V alloy submitted to conventional or electrolytic polishing, correlating the results with corrosion-fatigue strength testing performed in artificial fluoridated saliva. Specimens were also tested in air at room temperature to evaluate the effectiveness of the corrosion-fatigue test model. Material and methods. For cacti metal, 40 dumb-bell-shaped rods, 2.3 mm in diameter at the central segment, were cast. Conventional polishing was performed on 20 specimens of cacti metal following the manufacturer's instructions. A Source of continuous electrical current was used for electrolytic polishing of the other 20 specimens of each metal, which were immersed in an electrolytic solution containing 5% fluoridric acid, 35% nitric acid, and 60% distilled water. Surface roughness, Ka (mu m), was measured with a profilometer, and fatigue tests were carried out with a universal testing machine using a load 30% lower than the 0.2% offset yield strength. After failure, the fractured surfaces were examined using scanning electron microscopy. Surface roughness means were analyzed with a 2-way analysis of variance and the Tukey multiple comparisons test (alpha=.05). Results. Electrolytic polishing (0.24 +/- 0.05 mu m) provided significantly (P <.05) lower surface roughness values than conventional polishing (0.032 +/- 0.06 mu m). Regardless of the polishing protocol, surface roughness of Ti-6Al-4V alloy (0.25 +/- 0.06 mu m) was significantly lower (P <.05) than that of CP Ti (0.31 +/- 0.05 mu m), and the fluoridated environment did not influence fatigue performance. There was no correlation between fatigue performance and surface roughness. Conclusion. Surface roughness of Ti-6Al-4V was significantly lower than that of CP Ti. For cast titanium frameworks, the electrolytic polishing regimen was found to be more effective than the manufacturer's polishing instructions with abrasives and rotary instruments. After polishing, differences in surface roughness values did not affect corrosion-fatigue performance.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [1] Dynamic recrystallization of titanium and Ti-6Al4V alloy
    Salishchev, G
    Galeyev, R
    Zherebtsov, SV
    RECRYSTALLIZATION AND GRAIN GROWTH, VOLS 1 AND 2, 2001, : 961 - 966
  • [2] Ion nitriding of a commercially pure titanium alloy and of a Ti-6Al-4V
    Fare, S.
    Lecis, N.
    Vedani, M.
    Vimercati, G.
    Silipigni, A.
    Corti, D.
    Favoino, P.
    METALLURGIA ITALIANA, 2010, (06): : 13 - 18
  • [3] Corrosion-fatigue of laser-repaired commercially pure titanium and Ti-6Al-4V alloy under different test environments
    Zavanelli, RA
    Guilherme, AS
    Pessanha-Henriques, GE
    Nóbilo, MAD
    Mesquita, MF
    JOURNAL OF ORAL REHABILITATION, 2004, 31 (10) : 1029 - 1034
  • [4] Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments
    Zavanelli, RA
    Henriques, GEP
    Ferreira, I
    Rollo, JMDD
    JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (03): : 274 - 279
  • [5] DEFORMATION RESISTANCE IN PLATE ROLLING OF COMMERCIALLY PURE TITANIUM AND TI-6AL-4V ALLOY
    YAMAMOTO, S
    OUCHI, C
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 72 (06): : 595 - 602
  • [6] Morphological Studies on Machined Implants of Commercially Pure Titanium and Titanium Alloy (Ti6Al4V) in the Rabbit
    Palmquist, Anders
    Lindberg, Fredrik
    Emanuelsson, Lena
    Branemark, Rickard
    Engqvist, Hakan
    Thomsen, Peter
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 309 - 319
  • [7] Ti-6Al4V alloy by vacuum plasma spraying
    Jazi, HRS
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2005, 14 (02) : 175 - 176
  • [8] Influence of oxidative nanopatterning and anodization on the fatigue resistance of commercially pure titanium and Ti-6Al-4V
    Ketabchi, Amirhossein
    Weck, Arnaud
    Variola, Fabio
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2015, 103 (03) : 563 - 571
  • [9] Effect of Surface Polishing Treatment on the Fatigue Performance of Shot-Peened Ti-6Al-4V Alloy
    Liu, Z. G.
    Wong, T. I.
    Huang, W.
    Sridhar, N.
    Wang, S. J.
    ACTA METALLURGICA SINICA-ENGLISH LETTERS, 2017, 30 (07) : 630 - 640
  • [10] Surface roughness and fatigue strength of cpTi and Ti-6Al-4V after different polishings.
    Guilherme, AS
    Henriques, GEP
    Nobilo, MAA
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B133 - B133