Failure Analysis of CO Shift Gas Heat Exchanger Tubes

被引:0
|
作者
Cao, Huaixiang [1 ]
Zhang, Hao [1 ]
Song, Mingda [1 ]
Shen, Xiaomin [1 ]
机构
[1] Shandong Special Equipment Inspect Inst, High Tech Zone, 939 Tianchen RD, Jinan 250101, Shandong, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Tubes of a heat exchanger in a chemical plant leaked frequently, and such tubes will be replaced in one or two years. Therefore, it is necessary to find the leak causes and put in place preventive measures. In this paper, analysis methods such as macroscopic examination, the chemical composition test, metallurgical structure analysis, scanning electron microscopy (SEM) observation, energy spectrum (EDS) and X-ray diffraction (XRD) analysis of corrosion products and condensate water analysis are described that were conducted to analyze the leak causes of the heat exchanger tubes. After analyzing operating parameters (temperature, pressure) and the structure of the bottom area of the heat exchanger, it was found that the heat exchanger tubes inlet was operating in the vapor dew point zone. The results indicate that process parameters (temperature, pressure) were not properly selected and there were substantial SO42- in the process of production. As a result of that dew point corrosion in the form of pitting corrosion and stress corrosion cracking (SCC) which caused the leak occurred on heat exchanger tubes. Finally, relevant preventive measures were recommended according to the analysis results.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Failure Analysis of Spiral Plate Heat Exchanger
    Li Meng Li
    Wang Wei Qiang
    Tang Jie
    Ma Xiao Hui
    CHEMICAL, MECHANICAL AND MATERIALS ENGINEERING, 2011, 79 : 276 - +
  • [42] Failure Analysis of Tees on Heat Exchanger Inlet
    Fang, Yi
    Xu, Shugen
    Zeng, Qiang
    Wang, Chong
    Song, Mingda
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2019, 19 (03) : 782 - 791
  • [43] Corrosion Failure Analysis on Heat Exchanger Pipes
    Qiankun Z.
    Yafei S.
    Sixian R.
    Huifeng L.
    Xingjiang Z.
    Journal of Failure Analysis and Prevention, 2017, 17 (2) : 349 - 353
  • [44] Failure analysis of a heat-exchanger serpentine
    Azevedo, CRF
    Alves, GS
    ENGINEERING FAILURE ANALYSIS, 2005, 12 (02) : 193 - 200
  • [45] More on failure analysis of heat exchanger piping
    Zhu, C
    MATERIALS PERFORMANCE, 2003, 42 (11) : 9 - 9
  • [46] Numerical analysis of heat exchanger with inclined finned semicircular tubes☆
    Szydlowski, Mateusz
    Gutkowski, Artur
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 160
  • [47] Failure of Heat-Exchanger Tubes due to Localized Scaling and Microstructural Transformation
    Mansoor, M.
    Tauqir, A.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2008, 8 (05) : 434 - 440
  • [48] ROLLERS FOR ROLLING HEAT EXCHANGER TUBES
    KUZNETSO.ND
    COKE & CHEMISTRY USSR, 1967, (01): : 49 - &
  • [49] Restore corroded heat exchanger tubes
    Tallman, PM
    CHEMICAL ENGINEERING PROGRESS, 2000, 96 (08) : 47 - 50
  • [50] FOULING INSIDE HEAT EXCHANGER TUBES
    MORGAN, AI
    CARLSON, RA
    FOOD TECHNOLOGY, 1960, 14 (11) : 594 - 596